• Title/Summary/Keyword: 설비설계

Search Result 3,391, Processing Time 0.032 seconds

The Fact-finding and Analysis of the Environmental Management Cost in Construction Projects (건설공사의 환경관리비용 계상 및 운용 실태 분석)

  • Choi, Min-Soo;Kang, Woon-San
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.5 s.27
    • /
    • pp.186-192
    • /
    • 2005
  • The purpose of this study is to find the reality of environmental management cost in construction projects and to suggest some policies in order that owners appropriate the environmental management cost reasonably in the construction budget for reducing the environmental pollution at job sites. We surveyed the actual state of appropriating and expending the environmental management cost over 122 construction sites. According to the results of the survey, while the appropriated rate of the environmental management cost was 0.59% of the total construction cost. the expended rate reached at 0.94%. When examining the antipollution facilities which were operated in job sites, the investment for equipment against air-pollution such as tire washer, dust-proof device was relatively higher than other antipollution equipment. As the method appropriating the environmental management cost, we concluded that a quantity-per-unit costing method is more reasonable than appropriating at a fixed rate of total construction cost considering that there is little correlation between total construction cost and the environmental management cost. To do so, antipollution facilities that must be examined at a design or estimation stage of a construction project should be prescribed by the law. Moreover, referenced cost data for the quantity-per-unit costing should be prepared and officially published.

I3A Framework of Defense Network Centric Based C2 Facilities (국방 NC 기반 C2 시설 I3A Framework)

  • Kim, Young-Dong;Lee, Tae-Gong;Park, Bum-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.8
    • /
    • pp.615-625
    • /
    • 2014
  • Ministry of National Defense, MND, established a "Master Plan of Military Facility" in 2010 based on the defense reform to prepare for future war. It was a plan for consolidating small military facilities into battalion units, reflecting on and preparing for the needs of various changes in defense environment as well as balanced growth of ROK Army, Navy, and Air Force. However, to move forward with "Military Facility Master Plan," current design criteria for military facilities need to be revised to be enacted due to numerous calculation errors in facility footprints because of the absence of a sound facility criteria. Because the future war environment will be changed from Platform basis to Network Centric Warfare basis, Command & Control capability of C4I systems is getting more important. Therefore, Successful mission accomplishment can be secured by convergence of facility and military Information Technology(IT). So, MND should quickly prepare for the operational guidance, design criteria and policy that are suitable for Network Centric Warfare accomplishment, and implement infrastructure of IT and installation of C2 facility in conjunction with consolidation movement of military facilities. In this paper, we propose the defense I3A framework in order to solve this problem.

Assessment of Safety of Playground Equipment in Elementary Schools in Taegu (대구시내(大邱市內) 국민학교(國民學校) 놀이터의 안전성(安全性) 조사(調査))

  • Park, Jung-Han;Yun, Soon-Gil
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.414-427
    • /
    • 1991
  • To assess the safety of playground equipments in the elementary schools of Taegu, a site visit was made to 117 elementary schools out of 119 schools between 1st and 30th of April 1991. Safety criteria were developed on the bases of Massachusetts' Playground Safety Check List, standard height of Korean children of 6-12 years old, and source book for designing playground equipments. There were eleven different kinds of playground equipments installed in 117 schools but the number of equipments was about 50-60% of the minimum requirement set by the Ministry of Education except chin-up bar. Among the installed equipments, 47.3% of swings, 16.6% of parallel bars, 20.0% of monkey bars, and 16.0% of slides were broken down. None of the swings, slides, seesaws, monkey bars, and sandboxes met the safety criteria to the full but 59.0 of chin-up bars, 31.4% of Parallel bars, and 13,5% of stumps met the criteria fully. The proportions of equipments that were dangerous for children to play on were 26.4% for slides, 20.0% for monkey bars, 11.6% for seesaws, 10.4% for parallel bars, 9.8% for sandboxes, 7.4% for swings and stumps, and 3.9% for chin-up bars. The rests were either in need of repair or broken down. It was revealed by this survey that the playground equipments were too short in number to meet the minimum requirement, designs and size were not standardized, and many of the equipments were involved with the risk of child accidents. Therefore, a safety standard for the playground equipments should be developed and the existing equipments should be repaired immediately.

  • PDF

The Conceptual Design of Auto Releasing Emergency Wreck Marking Buoys (자동이탈식 비상침선표지 개발을 위한 개념설계 연구)

  • Gug, Seung-Gi;Park, Hye-Ri
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.417-422
    • /
    • 2016
  • Aids to Navigation (AtoN) are marine traffic facilities to improve the safety and efficiency of shipping. "New Dangers" should be appropriately marked using lateral, cardinal or isolated danger marks or by using an Emergency Wreck Marking Buoy. However, Emergency Wreck Marking Buoys are difficult to implement in terms of speed and accuracy of installation. In the case of sinking accidents, it is often difficult to immediately install an Emergency Wreck Marking Buoy because of weather conditions, the marine environment or accident positioning. This study concerns Auto-Releasing Emergency Wreck Marking Buoys, which should be installed in all vessel for safe marine navigation and efficient maritime transport with reference to the Maritime Buoyage System (MBS). Auto-Releasing Emergency Wreck Marking Buoys include an auto-release unit, auto reel chain and auto lighting lantern. These buoys can be automatically released from the deck of a vessel and will float in the water for quick installation at the scene of an accident, even in the case of sinking accidents. Auto-Releasing New Mark Buoys are expected to reduce to installation process, prevent secondary accidents by the risk of navigation and be search and rescue rapidly.

Electrical Characteristics and System Efficiency of the 5.9kW Phosphoric Acid Fuel Cell Power Generation System (소형 인산형 연료전지발전 시스템의 출현 및 효율 특성)

  • 정두환;이원용;이선근;임희천;신동열;최수현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.90-95
    • /
    • 1993
  • 수력, 화력, 원자력 다음으로 제 4의 전원으로서 관심의 대상이 되고 있는 연료전지는 연료가 가지고있는 화학에너지를 직접에너지로 변환시키는 점에서 종래의 발전 기술과는 원리적으로 다르며, 카르노(Carnot)사이클에 의한 에너지 변환 효율의 제한을 받지 않기 때문에 효율이 높으며 공해가 없는 특징을 가지고 있다. 연료전지의 발전 방식은 작동 온도, 전해질 등에 의해서 분류되나 현재 실용화단계의 기술은 인산형연료전지 발전이다. 인산형 연료전지의 발전용 연료는 천연가스, 메탄올, 납사 등과 같은 탄화수소 계열의 다양한 연료를 사용할 수 있으며, 이들 연료들을 수소가 많이 함유된 가스로 변환시켜 연료전지에 공급하여야 한다. 연료전지발전시스템 개발은 주로 전력이용 측면에서 천연가스를 개질연료로 사용하는 연구가 주류를 이루었으나, 최근에는 전 세계적으로 대기 공해에 시달리고 있는 도시의 환경개선을 위하여 도심용 버스 및 대형 트럭 등에 응용하기 위한 무공해 수송용 자동차엔진의 개발, 국방용 이동전원 개발 및 100㎾ 미만의 현지설치용 및 낙도용 전원으로서 메탄올을 연료로 한 연료전지의 개발이 활발히 진행되고 있다. 한국에너지기술연구소는 한국전력 기술연구원과 공동으로 1989년부터 1992년까지 본체를 제외한 5.9㎾급 인산형 연료전지 발전시스템 즉, 메탄올 연료 개질장치, 운전자동화 시스템, 배열이용 시스템, 종합 배관 등을 설계 구성하여 발전 플랜트의 운전 특성 연구를 수행하였으며, 본 고에서는 이들 설비들의 운전 특성과 발전 플랜트로서의 효율 특성에 대한 고찰을 수행하였다. 본 시스템은 연료개질기가 연결되고 배열을 이용하는 국내최초의 종합적인 연료전지 발전 시스템으로서 개질된 연료로 운전하였을 경우 본체의 효율은 31.9%, 배열을 회수한 종합발전 플랜트의 효율은 45.2%였다.로서, 흰쥐 유선이 LH의 생성처이면서 동시에 작용처이며 유선에서 합성된 GnRH의 조절하에 국부적인 인자로 작용할 가능성을 시사한다.f variation)가 10% 내외로 만족할 만한 범위에 들었다. 본 실험 방법을 타액과 혈청내 testosterone 농도 측정에 응용하여 RIA의 결과와 비교하여 본 바 상관관계가 타액에서 r=0.969, 혈청에서 r=0.990으로 두 결과가 잘 일치하였다. 본 실험에서 측정된 한국인 여성의 타액내 testosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Jap

  • PDF

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

A Study on Utilizing Instrumented Indentation Technique for Evaluating In-field Integrity of Nuclear Structures (원전 구조물의 가동 중 건전성 평가를 위한 연속압입시험법의 활용에 관한 연구)

  • Song, Won-Seok;Kim, Seung-Gyu;Ahn, Hee-Jun;Kim, Kwang-Ho;Kwon, Dongil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.165-172
    • /
    • 2013
  • Power generating unit structures are designed and built to meet standard to secure its safety for expected life time. As the structures have been exposed to combined environment, degradation of structure material is accelerated and it can cause unexpected damage; evaluating precise mechanical properties of weak site like welded area is an essential research area as it is directly connected to safety issues. Existing measuring technique like tensile test requires specific size in testing specimen yet it is destructive method which is hard to apply on running structures. To overcome above mentioned limitation, IIT is getting limelight as it is non-destructive and simple method. In this study, latest technique is introduced to evaluate tensile property and residual stress by analyzing stress field occurs under the indenter while IIT is performed. Test on welded area, the weak site of nuclear structures have been practiced and confirmed that IIT can be usefully applied to evaluate integrity in industry.

Design of waste Sludge/Food Waste Biological Treatment Process using Closed ATAD System (밀폐형 ATAD system을 이용한 하수슬러지/음식물쓰레기 통합처리 공정 설계)

  • Kwon, Hyeok-Young;Ji, Young-Hwan;Song, Han-Jo;Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.4
    • /
    • pp.129-137
    • /
    • 2000
  • In this study, biological treatment process of MWWT(Municipal wet-waste Treatment) has been developed through a moduling of the containerized closed ATAD(Auto thermal aerobic digestion) system & closed vertical dynamic acerator, which were used for food waste and cattle manure, respectively. Though biological process has several advantages such as low concentrations of heavy metals and salts, proper and stable C/N ratio and constant reaction rate against the process treating two wastes separately, it has a obstacles of salt concentration and much usage of bulking agent such as wood chip. After rapid oxidation in the boxed tower reactor for 5 days, the content of sewage sludge would be reduced 65% on around, might be mixed with the food waste that had been treated in the static closed reactor during 6 days and put in the secondary static reactor for curing. During composting process, the odor contained in the gas generated from the reactor was removed by passing it through a biofilter as well as the leachate was treated in the wastewater treatment facility. Consequently, it seemed to be possible to compost sewage sludge at mild and stable operating condition and at low cost through the biological ATAD process resulting in the production of organic compost satisfying the specifications regulated by itself.

  • PDF

Greenhouse Design for Subtropical Plants in Apartment Housing Complexes in Temperate Regions (온대지역 공동주택단지의 아열대 식물용 온실 설계)

  • Kim, Jai-Sik;Kim, Jeong-Moon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.6
    • /
    • pp.34-42
    • /
    • 2009
  • This study was executed to introduce a greenhouse style "Evergreen Park" to apartment complexes to target hands-on resident participation and application rather than a mere viewing of the plants as a way to provide convenient and profitable service to residents in a year-round center of usable outside space. The four key points can be summarized as follows: first, subtropical plants are evergreen broad-leaved trees, which maintain their green during all four seasons the leaves are thick and glossy. Greenhouses geared toward these subtropical trees-mainly broad-leaved evergreen species-are in planning to introduce these unique, elegant plants to temperate regions. Residentswill not only gain an education regarding these species but will be provided with the best quality evergreens at very reasonable maintenance costs. Second, subtropical plants greenhouses introduced in apartment complexes are suggested for structures connected via underground passage as well as free-standing structures so as to make use of geothermal heating and apply to reducing sunlighting. Third, as a way to provide (1) health & relaxation(evergreens, herb garden, water space), (2) community & education (plant flea market/plant hospital, plant-related lecture(exhibition), hands-on experience program), (3) a vine garden for year-round use such festivities as a Butterfly Festival, Aroma festival, Smile Oak Nuts, Candlelight Festival and Christmas Photo Site. Lastly, it has been suggested that the operation and maintenance of these greenhouses will be both by resident council operation management and by outsourcing company operation management.

Numerical Study of Turbulent Heat Transfer in Helically Coiled Tubes (나선형 튜브내의 난류 열전달에 대한 수치적 연구)

  • Yoon, Dong-Hyeog;Park, Ju-Yeop;Seul, Kwang-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.783-789
    • /
    • 2012
  • In this study, turbulent flow and heat transfer characteristics in a helically coiled tube have been numerically investigated. Helically coiled tubes are commonly used in heat exchange systems to enhance the heat transfer rate. Accordingly, they have been widely studied experimentally; however, most studies have focused on the pressure drop and heat transfer correlations. The centrifugal force caused by a helical tube increases the wall shear stress and heat transfer rate on the outer side of the helical tube while decreasing those on the inner side of the tube. Therefore, this study quantitatively shows the variation of the local Nusselt number and friction factor along the circumference at the wall of a helical tube by varying the coil diameter and Reynolds number. It is seen that the local heat transfer rate and wall shear stress greatly decrease near the inner side of the tube, which can affect the safety of the tube materials. Moreover, this study verifies the previous experimental correlations for the friction factor and Nusselt number, and it shows that the correlation between the two in a straight tube can be applied to a helical tube. It is expected that the results of this study can be used as important data for the safety evaluation of heat exchangers and steam generators.