• Title/Summary/Keyword: 설계 민감도 분석

Search Result 552, Processing Time 0.027 seconds

A Study on the Optimum Design of Three Span Continuous Preflex Composite Girder Bridge (3경간 연속 Preflex 합성형교의 최적설계에 관한 연구)

  • Koo, Min Se;Chang, Suong Su;Jeong, Jin Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.125-135
    • /
    • 1998
  • This study presents a design method for three-span continuous preflex composite girder bridges (3S-PCB) which imposes prestresses in the negative moment region by lifting or lowering interior supports and the design method is automated by a computer program which incorporates optimal design procedure. The objective function for the design of 3S-PCB minimizes the cost of construction materials and the constraint functions represent the limited dimensions of the design section and the allowable stress for each structural member as given in the specifications. Optimal design procedure used in this study is a modification of existing sequential unconstrained minimization technique (SUMT), a numerical analyses procedure for two-span continuous preflex composite bridges. The optimized design sections determined for each span length are compared with those of simple preflex composite beams (SPCB) and the optimal girder depth is determined by defining the relationship between girder depth and construction material costs.

  • PDF

A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

Parameter Analysis for Design of Pretension Girder Bridge for Urban Maglev Transit (도시형 자기부상열차 프리텐션 거더교의 설계변수 분석)

  • Lee, Jae-Ho;Kim, Do-Hak;Kim, Seung-Hyun;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2016
  • Parameter analysis of a pretension girder bridge for urban maglev transit was performed to identify the main design parameters and their effect. Girder deflection at mid-span is the most important design criteria of urban maglev transit. Therefore, concrete compressive strength, girder height, girder length, and unbonded tendon length were selected as the design parameters that relate to girder deflection. In addition, tendon layout and unbonded tendon ratios were also considered as design parameters to control the top stress of the pretension girder section at the support. The analysis results show that both the girder height and length are dominant design parameters governing girder deflection, more important than compressive strength and unbounded tendon length. And, sensitivity analysis makes this study suggest design weight value. In terms of stress, a tendon layout that can satisfy the unbounded tendon rule requires an additional tendon or rebar at the upper section to control the tensile stress on top of the section. Therefore, to improve feasibility and constructability in the future, an enhanced unbonded tendon rule considering the load characteristics of the urban maglev system should be studied.

Design of null lens for Alignment of the Unstable Laser Resonator (불안정형 레이저 공진기 정렬을 위한 null 렌즈 설계)

  • Kim, Hyun-Sook;Kim, Yeon-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.186-190
    • /
    • 2006
  • The use of null optics is proposed as a new concept for the precise alignment of a confocal unstable resonator. The characteristics of the proposed null optics are investigated and analysed with the designed null lens for a real confocal unstable resonator of which the length is 3.5 m. As a result of the analysis, the pupil map data are shown about the despace error of 1.0 mm and tilt error of 1.0 mrad.

체공형 부양선(Aerostat) 개념설계

  • Lee, Yung-Gyo;Kim, Dong-Min;Yeom, Chan-Hong
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.31-38
    • /
    • 2005
  • Conceptual design of an Aerostat was completed. Configuration was determined based on wind tunnel test results of aeostat hulls to have longitudinal static stability. Hull surface area and volume were obtained by using of Cubic spline method for given configuration and length. Final length of a hull was determined by iteration process. Cable tension and payload were estimated for conceptual design. A parametric study was performed for various weight and misson altitude. As results, a 30m class aerostat was designed and described.

  • PDF

Analysis of Consolidation considering Uncertainties of Geotechnical Parameters and Reliability method (지반특성의 불확실성과 신뢰성 기법을 고려한 압밀해석)

  • Lee, Kyu-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.138-146
    • /
    • 2007
  • Geotechnical performance at the soft ground is strongly dependent on the properties of the soil beneath and adjacent to the structure of interest. These soil properties can be described using deterministic and/or probabilistic models. Deterministic models typically use a single discrete descriptor for the parameter of interest. Probabilistic models describe parameters by using discrete statistical descriptors or probability distribution density functions. The consolidation process depends on several uncertain parameters including the coefficients of consolidation and coefficients of permeability in vertical and horizontal directions. The implication of this uncertain parameter in the design of prefabricated vertical drains for soil improvement is discussed. A sensitivity analysis of the degree of consolidation and calculation of settlements to these uncertain parameters is presented for clayey deposits.

Study on a Scheme to Increase Flood Reduction Effect of Washlands (강변저류지군의 홍수저감효과 개선방안에 대한 연구)

  • Baek, Chun-Woo;Byeon, Chen-Il;Kim, Do-Hyeon;Ahn, Tae-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.123-133
    • /
    • 2010
  • Due to climate change and difficulty in construction of large dam, it is on the increase to use small hydraulic facilities such as washland for the flood control purpose. Since there can be many potential locations for washland in a basin, it is important for determination of optimal location to calculate flood reduction effect of washlands substantially and exactly. In this study, a new scheme to increase flood reduction effect of washlands is suggested. Suggested scheme uses sensitivity analysis of flood reduction effect depending on washland characteristics such as storage volume, spillway elevation and spillway width. The characteristics of the washland is determined by results of sensitivity analysis to maximize flood reduction effect at basin outlet and downstream of a washland. The methodology is applied to Anseong river basin to show its applicability and applied result is compared with those of another studies.

Sensitivity Analysis of the CBS Ku-Band Antenna due to Manufacturing/Alignment Errors (CBS Ku대역 안테나의 제작/정렬 오차 민감도 해석)

  • 한재흥;윤소현;엄만석;박종흥;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.168-177
    • /
    • 2003
  • The performance sensitivity analysis due to manufacturing/alignment errors is performed for the Ku-band offset parabola antenna of the domestic Communications and Broadcasting Satellite. The performance variations due to reflector random surface error, which inevitably happens during reflector manufacturing, are statistically analyzed using RMS error and correlation interval. The impact on the antenna performance of the fred hem's position and angular errors is investigated, and the sensitive directions are identified. When the target tolerances are applied, the performance degradations are found to be within the loss budget or corresponding performance margins.