• 제목/요약/키워드: 설계초과지진

검색결과 60건 처리시간 0.023초

설계초과 지진에 대한 원전 지진안전성 평가기술 고찰 및 제언 (Review and Proposal for Seismic Safety Assessment of Nuclear Power Plants against Beyond Design Basis Earthquake)

  • 최인길
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.1-15
    • /
    • 2017
  • After Kyeongju earthquake occurred in September 12, 2016, the seismic safety of nuclear power plants became important issue in our country. The seismic safety of nuclear power plant against beyond design basis earthquake became very important to secure the public safety. In this paper, the current status of the seismic safety assessment methodology is reviewed and some aspects for the reliability improvement of the seismic safety assessment results are proposed. Seismic margin analysis and probabilistic seismic safety assessment have been used for the seismic safety evaluation of a nuclear power pant. The basic procedure and the related issues and proposals for the probabilistic seismic safety assessment are investigated.

좌굴방지가새가 설치된 철골건물의 초과강도계수 (Overstrength Factors of Buckling Restrained Braced Frames)

  • 김진구;박준희
    • 한국지진공학회논문집
    • /
    • 제8권6호통권40호
    • /
    • pp.67-72
    • /
    • 2004
  • 본 논문에서는 좌굴방지 가새 (BRBF)가 설치된 중저층 철골조 구조물의 초과강도계수를 평가하였다. 해석 모델의 설계변수로는 건물의 층 수, 경간의 길이, 가새의 항복강도, 지진하중의 크기, 반응수정계수 등 다양하게 설정하였다. 초과강도계수는 ATC-19에서 제시하고 있는 방법에 따라 정적 비탄성해석을 이용하여 산정하였다. 해석결과에 따르면 본 연구에서 구한 BRBF의 초과강도계수는 AISC/SEAOC에서 BRBF에 관하여 제시한 초과강도계수 값보다 전체적으로 크게 나타났다.

철근콘크리트 교각의 성능보장설계를 위한 휨 초과강도 (Flexural Overstrength of Reinforced Concrete Bridge Columns for Capacity Design)

  • 이재훈;고성현;최진호
    • 한국지진공학회논문집
    • /
    • 제10권5호
    • /
    • pp.85-97
    • /
    • 2006
  • 성능보장설계는 교각이 완전한 소성회전성능을 발휘할 때까지 다른 구조요소들과 교각 자체가 취성파괴 되지 않도록 설계하여 교량 전체 시스템의 연성파괴를 보장하기 위한 것으로서, 현행 도로교설계기준에는 명시적으로 규정되어 있지 않으나 대부분의 외국 교량내진설계기준에 채택되어 있다. 성능보장설계에서는 철근콘크리트 교각의 휨 초과강도를 구하고 이를 변환한 전단력을 교각, 기초, 말뚝에 작용하는 횡하중 설계전단력으로 결정하여 교각의 전단설계, 기초설계, 말뚝설계를 수행하도록 규정한다. 이 때 교각의 최대 소성모멘트를 결정하는 방법은 설계기준별로 각기 다른데, 이는 각 국의 재료 시공환경이 다르기 때문이다. 본 연구에서는 국내에서 사용하는 철근의 인장강도 측정치 3,407개와 콘크리트 압축강도 측정치 5,405개의 분석을 통하여 재료 초과강도계수를 제안하였고, 이를 적용하여 휨 초과강도를 결정하는 방법을 제시하였으며, 1,500개의 교각단면에 대한 모멘트-곡률 해석을 수행한 후 통계분석을 통하여 우리나라 실정에 적합한 초과강도계수를 제안하였다.

누적절대속도 개념을 고려한 지진손상표시기의 실험적 연구 (An Experimental Study on Seismic Damage Indicator Considering Cumulative Absolute Velocity Concept)

  • 이종림;권기주;이상훈
    • 한국지진공학회논문집
    • /
    • 제5권3호
    • /
    • pp.65-71
    • /
    • 2001
  • 원자력발전소(원전)는 운전기준지진(OBE) 초과지진 발생시 안전성 검사와 시험을 위하여 운전을 정지하여야 하는데, 계측된 지진기록의 누적절대속도(CAV)계산 값이 0.16g-sec를 초과하고 OBE 응답스펙트럼을 초과하면 OBE를 초과한 것으로 고려하게 된다. 이 CAV 기준은 발전소의 지진 특성과 구조물의 특성에 따라 다르므로, 발전소에 적합한 CAV 기준을 설정하여야 한다. 국내 원전에 적합한 CAV 기준 값을 설정하기 위하여, 각 방향에서의 지진하중에 일관되게 반응하도록 고안한 원통모양의 아크릴 봉을 조립한 지진손상표시기(SDI)를 제작, 진동대 시험을 통하여 지진의 세기를 평가하고 국내 원전 내진설계에 적용된 CAV값을 계산한 결과0.3~0.5g-sec으로 나타나 OBE 초과기준으로 CAV기준 값(0.16g-sec)의 적용은 충분히 보수적인 값으로 나타났다. 본 연구를 통하여 개발된 SDI는 발전소 운전원이 OBE 초과 여부를 판단하는데 도움을 줄 수 있을 뿐만 아니라 운전 정지 후 원전의 지진 피해도를 정량적으로 판단하여 조치를 취하는 도구로 활용될 수 있을 것이다.

  • PDF

설계기준초과지진에 대한 원전 배관 평가 방법 검토 (Review of Evaluation Method for Nuclear Power Plant Pipings under Beyond Design Basis Earthquake Condition)

  • 이대영;박흥배;김진원;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.56-61
    • /
    • 2016
  • After Japanese Fukushima nuclear power plant accident caused by the beyond design basis earthquake and tsunami, it has turned to be a major challenge for nuclear safety. IAEA, US NRC and EU have provided new safety design standards for beyond design basis event, Domestic regulatory bodies have also enacted guidances for licensees and applicants on additional methods related to beyond design basis events. This paper describes several evaluation methods for applying to nuclear power plants piping for beyond design basis earthquake. As a results, energy method based on the absorbed energy on nuclear power plant, deterministic method following design code and theory, experience method considering past earthquake data and information and probabilistic methods similar to probabilistic risk assessment were reviewed.

역V형 보통가새골조의 반응수정계수 (Response Modification Factors of Inverted V-type Ordinary Concentrically Braced Frames)

  • 김진구;남광희
    • 한국지진공학회논문집
    • /
    • 제8권3호
    • /
    • pp.53-62
    • /
    • 2004
  • 본 논문에서는 현행 내진설계방법에 따라 설계된 역V형 보통 가새골조 (OCBF)의 비선형 정적 해석을 수행하고, 그 결과를 바탕으로 초과강도계수, 연성계수, 반응수정계수 및 변위 증폭계수 등을 산정하였다. 해석결과에 따르면 대부분의 해석모델에서 현행 내진설계 기준에서 제시한 값보다 작은 초과강도계수 및 반응수정계수 값을 가지는 것으로 나타났다. 그러나 수직 보강 기둥 (zipper column)으로 가새를 보강한 경우 초과강도계수 및 반등수정계수는 보통 가새 구조물에 비하여 상당히 증가하는 것으로 나타났다.

잔교식 안벽구조물의 확률론적 지진위험도해석 (Seismic Risk Analysis of Steel Pile Type Pier)

  • 김동현;조홍연;김두기;조병일
    • 한국해안해양공학회지
    • /
    • 제19권3호
    • /
    • pp.237-243
    • /
    • 2007
  • 잔교식 안벽구조물의 확률론적 지진위험도 해석을 수행하였다. 부지응답해석을 통해 증폭된 지표 지진이 구조물에 가해질 때 강관파일의 조합응력비와 최대수평변위가 한계상태를 초과하는 확률을 지진취약도 곡선으로 표현하였다. 해당 지역의 지진발생확률은 항만설계기준의 지진재해도를 이용하여 최대지반가속도의 초과확률을 구할 수 있었다. 구조물의 최종적인 지진위험도는 지진취약도와 지진재해도를 이용하여 산정하였으며 수치해석 예제를 통해 그 결과를 제시하였다.

약지진동 지역의 저층 RC 골조의 초과강도 (Over-Strength of Low-Rise RC Frame in Low Seismic Zone)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제3권2호
    • /
    • pp.9-18
    • /
    • 1999
  • 현행 내진설계 기준과는 달리 내진설계기준연구(II) 에서는 6층 미만의 건물도 내진설계를 적용하도록 제안하고 있다 이 제안서가 향후 내진설계 기준의 근간이 된다면 저층 건물에 대하여서도 내진설계가 수행되어야 할 것으로 예상된다 지진의 세기로 구분할 때 국내의 약지진동 지역으로 구분되며 이와 같은 지역에서의 저층 건물의 초과강도 계수 $\Omega$는 매우 크다고 기조의 연구자들이 보고하고 있다 따라서 본 연구에서는 국내 4층 RC 모멘트 연성 골조의 경우에$\Omega$를 고찰하고자 스팬과 경간(bay)를 변화시키면서 모델을 설계하고 이를 2차원 push-over 해석하였다 수치해석 결과 경간의 수 또는 스팬 길이가 증가함에 따라$\Omega$의 값이 증가하는 추세를 보였다 이는 내진설계시 우발 비틀림 모멘트를 고려함으로 스팬 길이 또는 경간 수의 증가에 비하여 외부기중의 설계강도증가율이 크기 때문이다 또한 외부 기둥의 강도증가는 강기동-약보 모델에 근접한 붕괴기구를 형성하므로 $\Omega$의 증가에 영향을 미치는 것으로 고찰되었다

  • PDF

Fukuoka 연속 지진의 관측자료를 이용한 수평 응답스펙트럼 특성 분석 (Analysis of Characteristics of Horizontal Response Spectrum of Ground Motions from Fukuoka Earthquakes Series)

  • 김준경
    • 터널과지하공간
    • /
    • 제24권5호
    • /
    • pp.354-365
    • /
    • 2014
  • 2005년 3월 20일 규모 6.5의 후쿠오카 본진이 발생하였고 이후 발생한 규모 3.7 이상의 15 개 중규모 후쿠오카 지진으로부터 관측된 지반진동 파형을 이용하여 수평 응답스펙트럼을 분석하였다. 결과를 국내 원자력 관련 구조물의 내진설계 기준과 국내 일반 구조물 및 건축물 내진설계기준과 각각 비교하였다. 수평성분 178개 지반진동을 이용하여 고유진동수별 지반응답을 구하고 최대 지반 가속도 값을 이용하여 정규화 분석을 수행하였다. 연구결과는 응답값에 대한 진앙거리 의존성이 대단히 크다는 것을 보여주었다. 또한 국내 원자력시설물의 내진기준인 Regulatory Guide 1.60과 비교한 결과는 일부 구간 즉 약 8 ~ 10 Hz 구간과 약 16 ~ 20 Hz의 2개의 구간에서 표준편차를 더한 값이 Regulatory Guide 1.60 보다 약간 초과함을 보여 주었다. 또한 국내 일반 구조물 및 건축물 내진설계 응답스펙트럼을 3 개 지반조건에 적용한 결과는 거의 모든 주기 대역에서 분석된 응답스펙트럼이 SE 지반조건의 설계 응답스펙트럼(500년 재래주기, 지진구역 1, SE 지반조건)을 초과하고 있다. 500년 재래주기는 가장 약한 내진 설계기준에 해당하기 때문에 거의 모든 주기 대역에서 본 연구로부터 분석된 응답스펙트럼이 해당 기준을 초과하고 있다. 신뢰성을 보다 증가시키기 위해 향후 한반도 및 한반도 주변 해외 발생지진으로부터 관측된 지진자료를 대폭적으로 보강하여 관측 지진자료의 다양성을 유지하는 것이 필요하다.