• Title/Summary/Keyword: 선형 빔

Search Result 337, Processing Time 0.039 seconds

A Study on the Design of the Warper Beam Considering Friction (마찰을 고려한 경편기용 정경빔의 설계에 관한 연구)

  • 임문혁;김영규;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.140-148
    • /
    • 2003
  • An analysis fur the warping process has been performed to design the warper beam. Nonlinear material response is included in the physical model of polyester yarn. Large deformation finite element simulation considering contact and frictional analysis are used to obtain the pressure on the barrel of the warper beam. Loading condition on the flange is assumed by using the pressure on the barrel, winding number of yarn, Poisson's ratio of fiber, and fiber volume fraction. By using the above loading conditions NASTRAN finite element simulation is performed to calculate stress distribution and deformation of the warper beam. By comparing the deformed shape of the flange with experimental result, loading condition on the flange has been obtained. The obtained loading conditions on the barrel and flange can be utilized to design the warper beam.

Improvement of the performance of SPPCM using mixed polarized beam and cylindrical lens (혼합 편광빔과 원주면렌즈를 사용한 SPPCM의 성능 개선)

  • Yi, Eun-Hyeong;Kim, Seong-Wan;Kim, Cheol-Su;Kim, Jong-Yun;Lee, Seung-Hee;Lee, Soo-Joong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.56-63
    • /
    • 1999
  • Conventional method to improve the response time of the Cat-SPPCM was to increase fanning beam using cylindrical lens. But, in this case the temporal instability of this SPPCM is increased, and fanning beam plays a role as noise, so that it decreases the reflectivity. Thus, fanning beam must be controlled to improve the properties of SPPCM. In this paper, we propose the method to increase the reflectivity of SPPCM and decrease the response time by focusing line-shaped input beam into photorefractive crystal using cylindrical lens and decrease the temporal instability of output beam by using mixed-polarized beam instead of simple extraordinary polarized beam. Optical experiments show that the reflectivity of proposed SPPCM is increased twice and the response time is reduced by 15 times. Also, we observed that the temporal instability of SPPCM is reduced when the polarization angle of the mixed-polarized beam is between $10^{\circ}$ and $30^{\circ}$ . We used a $45^{\circ}-cut\;BaTiO_3$ crystal which has high electro-optical coefficients in optical experiments.

  • PDF

원통형 Saddle Field Ion Source의 특성에 관한 연구

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.234-234
    • /
    • 2012
  • Saddle field ion source는 구조가 간단하고 영구자석을 사용하지 않아 소형화에 유리하고 구조가 간단한 DC 파워서플라이를 이용하기 때문에 장치 가격이 저렴하여 다양한 분야에서 응용되고 있으며 특히 이온빔 밀링 분야에 많이 사용된다. 초기 saddle field ion source 는 대칭형의 구형이었으나 지속적인 연구 개발로 와이어형, 원판형, 원통형 등 다양한 형태의 saddle field ion source가 개발되었다. 본 연구에서는 비교적 제작이 용이하고, 구조적으로 외부간섭에 대하여 덜 민감한 원통형 saddle field ion source를 제작하였다. 초기 saddle field ion source는 이온원 내부에 saddle field를 형성하기 위하여 대칭 구조를 가지 형태로 제작되었으나, 비대칭 구조에서도 saddle field가 형성될 수 있고 비대칭 구조를 채택할 경우 한쪽으로 더 많은 이온빔을 인출할 수 있기 때문에 실제 응용면에서는 비대칭 구조가 더 유리하다. 따라서 본 연구에서는 원통형 비대칭 saddle field ion source를 제작하였으며, 제작된 이온소스는 높이가 62 mm 지름이 55 mm의 소형 이온소스였다. 제작된 원통형 saddle field ion source는 진공도와 가속전압에 따라 방전 모드 변화하였다. Saddle field ion source는 전극과 extractor의 구조에 따라 조금씩 다르지만 대체로 5x10-5 Torr ~ 5x10-4 Torr 영역에서 안정적으로 작동하였다. 이온소스 내부의 압력이 높을 경우 수십 mA 의 방전 전류가 흐르는 고전류 방전 모드로 작동하였으며 압력이 낮을 경우에는 동일한 전압에서 수 mA 의 방전 전류만 흐르는 저전류 방전 모드로 작동하였다. 압력이 더 높아질 경우 아크 방전이 발생하여 이온소스의 작동이 불안정하여 연속적인 작동이 어려웠다. 고전류 방전 모드에서는 이온빔 전류가 Child-Langmuir 방정식에 따라 Vi3/2에 비례하여 증가하는 경향을 보여주었으며 저전류 방전 모드에서는 Vi에 선형적으로 증가하였다. 가속 전압이 동일한 경우 고전류 방전 모드가 저전류 방전 모드에 비하여 더 많은 이온빔 인출이 가능하지만, 고전류 방전 모드의 경우 이온의 방출 각도가 매우 넓은 반면 저전류 방전 모드에서는 이온빔의 퍼짐이 현저히 줄어듦을 관찰할 수 있었다. 원통형 saddle field ion source는 내부 구조가 간단하기 때문에 내부 전극의 구조 변화에 따라 방전 특성 및 이온빔 인출 특성이 심하게 변동하였다. Saddle field ion source에서는 Anode에 인가되는 방전 전압이 가속 전압과 같은 역할을 하는데 가속 전압은 2~10 kV 사이에서 인가가 가능하였다. 일반적으로 동일한 방전 모드에서 진공도가 높아질수록 방전 전류의 양과 인출되는 이온의 양이 증가하는 것이 관찰되었다. 제작된 이온소스는 최적 조건에서 5 mm 인출구를 통하여 0.7 mA의 이온빔 인출이 가능하였으며, 9 mm 인출구를 사용한 경우 1 mA까지 이온빔 인출이 가능하였다.

  • PDF

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Design of Linear Interferometer Antenna Regarding Beamwidth (빔폭을 고려한 선형간섭계 안테나 설계)

  • Choi, Ik-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.693-700
    • /
    • 2016
  • In this paper, it is represented that equations for design of linear interferometer antenna when the 3 dB beamwidth is only region of interest. Using the equations, relationships between angle measurement ambiguity and element antenna spacings are described. And then, operating frequency, angle measurement accuracy, beamwidth, correct measurement probability are calculated for five antennas interferometer to measure azimuth and elevation angle. The interferometer antenna was designed and fabricated using the calculated parameters. The angle measurement accuracy were $0.01^{\circ}$ and $0.016^{\circ}$ for azimuth and elevation axes with 99 % probability of doing measurements correctly which means that ambiguous solution did not occur more than 1 % of the time. These results validated the equations and design procedures.

Fully Non-Contact Assessment of Acoustic Nonlinearity According to Plastic Deformation in Al6061 Alloy (Al6061 합금의 소성변형에 따른 음향비선형 특성의 완전 비접촉식 평가)

  • Lee, Hyeon;Chung, Cheon;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.388-392
    • /
    • 2012
  • This study proposes a fully non-contact measurement method to assess acoustic nonlinearity of narrowband surface waves generated by a line-arrayed laser beam by using a laser-ultrasonic detector in the way of two-wave mixing (TWM) method. This method was applied to figure out a relationship between plastic deformation and nonlinearity characteristics of a plastically deformed aluminum specimens. The experimental results showed that the acoustic nonlinearity of the laser-generated surface wave increased proportionally to the level of tensile deformation. This tendency is in good agreement with the result of measurement by contact method with PZT-transducer.

Synthetic Aperture Sonar for Conformal Towed Array (왜곡된 형상을 갖는 어레이를 위한 합성 처리 기법)

  • 김준환;양인식;김기만;오원천;도경철
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.77-83
    • /
    • 2000
  • The previous synthetic aperture techniques have been investigated to increase signal gain, improve angular resolution and peak-to-sidelobe level ratios for towed line array sonar systems. The synthetic aperture method in this paper is performed for conformal array systems by mapping real elements on an axis to control like a linear array. The proposed method for the conformal array performs coherent processing of subaperture signals at successive time intervals in the beam domain via FFT transformations. This was confirmed by the simulation results and compared to the results from use of the synthetic aperture technique under the conformal array.

  • PDF

Effect of Finite Substrate Size on the Radiation Characteristics of H-plane Linear Array Antennas (유한한 기판 크기가 H-평면 선형 배열 안테나의 방사 특성에 미치는 영향)

  • Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.39-49
    • /
    • 2013
  • The effect of the finite substrate size on the radiation characteristics of H-plane linear microstrip array antennas is investigated. The radiation characteristics versus scan angle are systematically analyzed for 5-element H-plane linear array antennas with various substrate sizes and element spacings for the substrates with different dielectric constants. The distance between the antenna center and the substrate edge on the E-plane for the enhancement of the radiation characteristics of the array antenna is presented.

A Study on $He^+$ Ion Beam Extraction in the Duoplasmatron Ion Source (Duoplasmatron 이온원에서의 $He^+$ 이온빔 인출에 관한 연구)

  • Myong-Seop KIM;Hae-iLL BAK
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.438-443
    • /
    • 1991
  • The operational characteristics of the duoplasmatron ion source are investigated in order to obtain the maximum achievable extraction current of the $He^+$ ion beam with the small divergence. Under the variations of the gas pressure, the arc current, the magnet current and the extraction voltage of the ion source, the change of the extracted $He^+$ ion beam current is observed. An oxide filament, the mixture of BaO and SrO coated on Ni meshes, is used as the hot cathode, and its average lifetime is about 100 hours. The extraction current is linearly proportional to the arc current. As the magnet current of the ion source is increased, the extraction current increases, but the beam divergence becomes larger. The maximum extraction current is obtained at the source pressure of 0.084 Torr. The extraction current is proportional to the extraction voltage raised to the power of 3/2 as estimated from theory. At the extraction voltage of 5.72 kV, the maximum extraction current of 50 $\mu$A is obtained under the optimized extraction condition.

  • PDF