• Title/Summary/Keyword: 선행냉각

Search Result 51, Processing Time 0.025 seconds

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.

Analysis of Frequency Response Curve for Conduction-Cooled Power Capacitors (전도 냉각 파워 커패시터의 주파수 응답 곡선 분석)

  • An, Gyeong Moon;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.123-130
    • /
    • 2016
  • High-frequency induction heating equipment can heat the metal by applying a High-Frequency power to the resonant circuit. The resonance circuit is composed of the work coil and the conduction-cooled power capacitor, it influences the performance of the heat treatment equipment according to the characteristics of the capacitor. However, dependence on conduction-cooled power capacitor's import is high due to lack of core technology research and development. Minimizing the generation of internal heat transmitted inside during LC resonance, reduce the reactive power loss, there is a need for a capacitor within the voltage characteristic outstanding. To implement localization it is vital that prior study of the analysis on the frequency response characteristic for the finished capacitor advanced manufacturer be implemented. Studying the interpolation method to read the value at any point of the characteristic curve for a given log-log scale was applied to the analysis tool of the capacitor by my proposed algorithm. The simulation for reproducing frequency response curves was attempted by assuming a capacitor in a simplified series equivalent RC circuit to obtain the equivalent series resistance value. It was confirmed that the reproduction rate was the result value above 83% as compared to the simulation of the properties and characteristics on the actual reactive power for Peak value, and that the algorithm can be applicable when analyzing and predicting the characteristic curves of a simpled model capacitor.

80K 200W급 단단 G-M 극저온 냉동기 개발에 따른 성능평가(2)

  • Lee, Dong-Ju;Han, Myeong-Hui;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.93.1-93.1
    • /
    • 2015
  • 근래 디스플레이 분야에서 OLED가 시장을 주도하면서 이 공정에 가장 적합한 진공펌프로 크라이오 펌프가 주목을 받고 있다. 화소 형성 공정에 사용되는 유기물이 수분에 취약하기 때문인데, 크라이오 펌프가운데서 특별히 수분만 집중적으로 배기할 수 있는 워터펌프(CWP or cold trap)가 각광받고 있다. 이에 HM GVT는 중소기업청 중소기업개발지원사업의 일환으로 진행된 2014년도 구매조건부 신제품 개발사업에 선정되어 '극저온 G-M냉동기를 이용한 대용량 Cold Trap개발' 과제를 수행하면서 32인치 급으로 수분에 대해서 30,000 [L/s] 이상의 배기속도를 가지는 대형 CWP를 개발하고 있다(수요처: (주)아바코). 통상적으로 흡기구가 30인치라면 수분 배기속도는 대략 65,000 L/s에 이르고 200 W 냉각능력이면 최대 수분 분압 0.008 mbar에서 작동시킬 수 있다. 따라서 1차년도의 목표는 큰 배기용량과 대형 사이즈의 CWP를 개발하기 위해 80 K에서 200 W 이상의 냉동능력을 보유한 단단 G-M 극저온냉동기를 선행 개발하는 것이다. 이에 현재 최대 냉동능력 80 K에 130 W의 냉동능력을 가지는 HPS055모델을 이용하여 다양한 예비시험들을 수행하여 최적의 설계인자들을 도출하였고 이를 근거로 80 K에서 200 W 이상의 냉동능력을 가지는 HPS80200모델을 설계 및 제작, 성능시험을 수행하였다. 이에 국내 최초로 80 K에서 200 W의 냉동능력을 가지는 단단 G-M냉동기를 개발하였고 설계 및 제작에 대한 원천기술을 확보할 수 있었다.

  • PDF

High Casting Technology for Aluminium Alloy Die Casting (I) (알루미늄합금 다이캐스트 주조기술 고도화(I);주조방안 선정 기술)

  • Kim, Eok-Soo;Lee, Kwang-Hak
    • Journal of Korea Foundry Society
    • /
    • v.18 no.3
    • /
    • pp.211-221
    • /
    • 1998
  • 주조방안이란 주형(금형)에 공동부를 어떻게 설계하고 공동부의 어떤 위치에 어떻게 탕도, 탕구 등을 설계할 것인지, 또 over-flow 및 air-vent는 어떻게 설계하여 가스뽑기 및 용탕을 공동부에 원활히 충진시켜 완전한 제품을 얻을 수 있을까에 대한 제반적인 주조방법의 계획이다. 즉, 용탕을 공동부에 충진시키는 시스템이며, 주조상에 발생하는 제문제 및 주조제품의 품질에 가장 큰 영향을 미치는 요소 중의 하나이다. 따라서 만약 주조방안 시스템이 부적절하여 불량률이 높은 경우에는 대폭적인 금형수정이나 경우에 따라서는 불가피하게 금형을 신작해야 하는 큰 문제도 야기될 수 있다. 또한 기본적인 품질문제로 탕회, 탕경, 크랙 등의 외관불량과 기동 등의 내부결함, 내압불량등도 유발될 수 있다. 그러나 이러한 불량대책으로 쉽게 주조방안을 수정하는 것은 주조 시스템 자체가 변해버리기 때문에 피해야 하며 다른 대책을 선행하여 해결할 수 없었을 때 최종적으로 신중히 검토 후 주조방안을 수정하는 것이 바람직하다. 따라서, 본고에서는 Al합금 다이캐스트 주조기술에 있어 주조품질을 결정하는 중요한 요소인 주조방안의 효과적인 설계를 위한 주조기 선정, 금형분할면 선정, 탕구계의 설계와 탕구선정, over-flow 및 air-vent설계, 수축여유 및 금형냉각방안 선정기술에 대한 기본적 방안을 제시하고 실제 주조방안의 대표적인 사례를 소개하고자 한다.

  • PDF

Prediction of Complex Turbulent Flows in Can-type Gas Turbine Combustor and Scroll (원통형 가스터빈 연소기와 Scroll 내부유동장 해석)

  • 김용모;김성구;김명환;민대기
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.9-9
    • /
    • 1998
  • 가스터빈 연소기의 난류유동장을 구성하는 기본적인 유동형태는 크게 밀폐관내의 돌연 확대를 가지는 동축제트, 선회유동, 그리고 연소공기공 및 회석공기공을 통해 연소실에 수직방향으로 유입되는 제트유동 등으로 분류할 수 있다. 실제 가스터빈 연소기내의 난류유동장을 수치해석하기 위해서는 임의의 형상을 갖는 3차원 유동장을 모사할 수 있는 수치해석법과 고차정확도를 유지하면서도 수렴안정성을 만족시키는 대류항 처리기법 등과 같은 수치모델의 개발이 선행되어야 하며, 이와 함께 복잡한 난류연소유동장을 정확히 묘사할 수 있는 난류모델 및 난류연소모델의 개발 및 검증이 가장 중요한 요인이 된다. 또한 가스터빈 연소기의 최적 설계는 넓은 작동구간에서 높은 효율, NOx 및 CO 배기량의 저감, 희박연소 가연한계의 확장, 연소계통에서의 낮은 압력강하, 낮은 연소벽면온도와 온도구배를 유지시키기 위한 공기에 의한 충분한 냉각 같은 서로 상충되는 설계조건을 만족해야 한다. 그리고, 이러한 상충된 연소설계조건들을 충족시키는 최적 연소기의 설계를 위해서는 실험적인 연구뿐만 아니라 연소기내의 물리적인 현상을 잘 반영할 수 있는 물리적 모델을 바탕으로 한 연소유동의 해석적인 연구를 필요로 한다. 본 연구에서는 원통형 가스터빈 연소기의 등온 및 연소유동장, 그리고 연소기와 연결되는 Scroll 내부의 난류유동장에 대한 수치해석을 수행하여 수치 및 물리모델의 예측능력을 검증하였고, 가스터빈 연소유동장 해석에 관련된 중요 논점들에 대하여 심도있게 분석하였다.

  • PDF

Experimental investigation of intrusive gravity current in stratified fluid (성층화된 유체 내에서 침입중력류의 실험적 연구)

  • Paik, Joong-Cheol;Son, Shin-Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.173-173
    • /
    • 2012
  • 중력류는 두 유체 사이에서 물질의 종류 또는 온도차로 인한 밀도 차이에 의해 발생되는 유체의 흐름을 말하며, 자연환경에서는 저수지에서의 중층탁류, 사막에서의 모래 폭풍, 하구에서의 염수쐐기 등이 그 예이다. 여름철에 강우가 집중되는 우리나라는 홍수에 의한 범람, 침수 등이 발생할 뿐만 아니라 댐이나 하천, 호수 등에 흙탕물이 유입되어 중간층에 정체하는 중층탁류에 의한 피해가 자주 발생하고 있다. 과거에 중층탁류는 일시적인 현상에 불과하였으나 오늘날에는 인공적으로 형성된 정체성 호수나 하천에서 장기간 체류하여 생태계의 교란과 수질 악화를 초래하고 있다. 중층탁류에 의한 피해를 저감시키기 위해서는 본래 자연 상태의 하천이나 호수와 같이 온도분포가 비선형적으로 성층화 된 상태에서 탁수가 유입되어 중층탁류가 형성되는 과정과 흐름 특성을 이해하는 것이 선행되어야 한다. 본 연구에서는 중력류 흐름 해석을 위한 실험 장치를 개발하였다. 실험 장치 중 수조의 제원은 1200 $700{\times}300mm$이며, 수조 상부에는 가열장치를 설치하였고, 수조 하부에는 냉각장치를 설치하였다. 이들 장치들을 가동하여 깊이에 따른 자연현상에서의 비선형적인 온도 단면을 재현한다. 수리 실험방법은 깊이 방향으로 온도에 따라 비선형적으로 성층화 된 유체 내로 경사가 있는 판을 따라 수조내의 성층화된 유체의 중간 온도 혹은 밀도를 가진 유체를 침입시킨다. 침입유체는 성층화된 유체 내에서 초기에는 중력에 의해 운동량을 갖고 경사면을 따라 일정한 속도로 흘러내려 간다. 이후 바닥으로 하강 한 후 부력에 의해 상승하여 동일한 밀도층의 위치에서 횡방향으로 전파하게 된다. 이 연구에서는 이와 같이 비선형적으로 성층화된 유체 내에서의 침입 중력류의 흐름 특성을 실험적으로 관측하고 분석한다.

  • PDF

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

Optimization of flow performance by designing orifice shape of outdoor unit of air-conditioner (에어컨 실외기 냉각팬 시스템의 오리피스 형상 설계를 통한 유량 성능 최적화)

  • Ryu, Seo-Yoon;Kim, Sanghyeon;Cheong, Cheolung;Kim, Jong-Uk;Park, Byeong Il;Park, Se Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.6
    • /
    • pp.371-377
    • /
    • 2017
  • The performance of an air conditioner is closely related to the cooling performance of a split-type outdoor unit so that, in most of the relevant preceding studies, the independent performance of an axial fan in an outdoor unit has been studied. However, there is a lack of research on the effects of other components in an outdoor units was rarely investigated. Therefore, in this paper, the effects of the fan orifice among other parts on the flow performance of the outdoor unit was numerically investigated. A virtual fan tester consisting of 18 million grids was developed for highly resolved flow simulation. The unsteady RANS (Reynolds-averaged Navier-Stokes) equations are numerically solved by using finite-volume CFD (Computational Fluid Dynamics) techniques. In order to verify the validity of the numerical methods, the predicted P-Q curve of the cooling fan in a full outdoor unit is compared with the measured one. Optimization of orifice shape was carried out for maximum flow performance of the outdoor unit using the validated numerical method.

A Study on the Method for the Removal of Radioactive Corrosion Produce Using Permanent and Electric Magnets

  • Kong Tae-Young;Song Min-Chul;Lee Kun-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • The removal of radioactive corrosion products from the reactor coolant through a magnetic filter system is one of the many approaches being investigated as a means to reduce radiation sources and exposures to the operational and maintenance personnel in a nuclear power plant. Many research activities in water chemistry, therefore, have been performed to provide a filtration system with high reliability and feasibility and are still in process. In this study, it was devised the magnetic filter system with permanent and electric magnets to remove the corrosion products in the coolant stream taking an advantage of the magnetic properties of corrosion particles. Permanent magnets were used for separation of corrosion products and electric magnets were utilized for flocculation of colloidal particles to increase in their size. Experiments using only permanent magnets, in the previous study, displayed the satisfactory outcome of filtering corrosion products and indicated that the removal efficiency was more than 90 $\%$ for above 5 $\mu$m particles. Experiments using electric magnets also showed the good performance of flocculation without chemical agents and exhibited that most corrosion particles were flocculated into larger aggregates about 5 $\mu$m and over in diameter. It is, thus, expected that the magnetic filter system with the arrangement of permanent and electric magnets will be an effective way for the removal of radioactive corrosion products with considerably high removal efficiency.

  • PDF

Post-slaughter Intervention Techniques to Ensure Tenderness of Beef Muscles for Korean Consumers (한국 소비자 쇠고기 연도 보증을 위한 도축후 도체 처리기술)

  • 황인호
    • Journal of Animal Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.921-932
    • /
    • 2006
  • Management to improve beef tenderness is always been a historical idea, but during the recent past it has become an issue of prime importance to the meat scientists and the industries as well. Variation in tenderness is the prime explanation for consumer’s dissatisfaction for the concern meat. It has been well documented that both postmortem proteolysis and sarcomere length have significant effect on meat tenderness and its consistency. Electrical stimulation and tenderstretch techniques have been used by a number of countries to underpin carcass quality assurance schemes focused on eating quality. The mechanism(s) by which the postmortem interventions improve tenderness (or prevent toughness) has not been fully elucidated. However, it is evident that electrical stimulation accelerates the development of rigor mortis so that prevention of cold shortening is possible and ageing commences at higher temperatures. On the other hand, tendersretch appears to prevent meat toughness via placing tension of the myofibrils and connective matrix during rigor development. Previous findings indicated that electrical stimulation and tenderstretch improved beef tenderness even for fattened cattle under moderate chilling conditions. Recent studies demonstrate beef tenderness to be one of the most important factors determining satisfaction levels of Korean beef consumers. There are number of studies which reported that electrical stimulation and tenderstretch techniques improved Hanwoo tenderness and color. It is believed that the techniques are mostly useful wherein controls of carcass size, fatness and/or chilling regimes are not easy such as Korean beef industry. However, Korean beef industry is one such area where postmortem intervention techniques have not been adopted so far. Taking into consideration of the Korean beef industry, wherein carcass size and fatness varies the post-slaughter intervention technique could be the most feasible measurement to ensure eating quality. The manuscript attempts to highlight the current knowledge aiming primarily towards the assurance of beef tenderness.