• Title/Summary/Keyword: 선장

Search Result 242, Processing Time 0.028 seconds

Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants (월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가)

  • Jin, Yung-Kwon;Kim, Yong-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.53-64
    • /
    • 1995
  • The radiation fields following the large loss of coolant accident (LOCA) have been assessed for the vital areas in the service building of Wolsong 2, 3, and 4 nuclear power plants. The ORIGEN2 code was used in calculating the fission product inventories in the fuel. The source terms were based upon the activity released following the dual failure accident scenario, i.e., a LOCA followed by impaired emergency core cooling (ECC). Configurations of the reactor building, the service building, and the ECC system were constructed for the QAD-CG calculations. The dose rates and the time-integrated doses were calculated for the time period of upto 90 days after the accident. The results showed that the radiation fields in the vital access areas were found to be sufficiently low. Some areas however showed relatively high radiation fields that may require limited access.

  • PDF

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

A Placement Prablem with Wire Congestion in LSI Layout CAD (LSI의 Layout CAD에 있어서의 배선 혼잡도를 고려한 배치 문제)

  • Im, In-Chil;Jeong, Jeong-Hwa;Lee, Byeong-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.3
    • /
    • pp.19-27
    • /
    • 1982
  • Minimization of total routing and number of cuts has been adopted for the placement problem in LSI and printed wire board as the object function, recently. Although it is considered that in the general situation this object function reflects the final goal which is wiring of 100% of layout, it often seems to be insufficient because it does not exhibit partial wire congestion. This paper introduces a new concept called the wire congestion of segestion to get the partial wire congestion and proposes the object function to minimize the wire congestion of segmests. In order to optimize this object function, an effective heuristic algorithm is also suggestsl Experimental results show that this algorithm sustains its efficiency. The experimental consequences point out that if the total routing length is short, maximum wire congestion of segment is small and vice versa. Therefore control parameter, that is, congestion parameter, which mintnizes total length and concurrently reduces maximal wire congestion of segment, is obtained by experiment.

  • PDF

Development of Dose Evaluation Algorithm for Film Badge Using ISO Reference Radiations (ISO 표준방사선장을 이용한 필름배지의 선량평가 알고리즘 개발)

  • Kim, Jang-Lyul;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1995
  • Since provisions on the technical criteria for personnel dosimetry was amended three years ago, several improvements in the technique of monitoring personnel doses by TLD have taken place, but for the photograpfic film as a personnel monitor, additional investigations should be carried out for its accuracy of dose estimates because of its wide use in the radiation involved industries. So, this paper describes the methods to develope dose evaluation algorithm for photographic film using ISO reference radiations by i) empirical formula, ii) degree-of-fit method, and iii) matrix approximation. These methods show a good agreement between irradiated and calculated dose within tolerance level represented in ANSI N13. 11, and can be used for the dose evaluation of X, ${\gamma}$ and/or radiation fields.

  • PDF

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

Analysis of Gamma Radiation Fields in the MAPLE-X10 Facility Associated with Loss-of-Pool-Water Accident Conditions (LOSS-OF-POOL-WATER 사고시 연구용 원자로 MAPLE-X10 시설에서의 감마 방사선장 해석)

  • Kim, Kyo-Youn;Ha, Chung-Woo;I.C. Gauld
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.63-72
    • /
    • 1989
  • An analysis for the gamma radiation fields in the research reactor MAPLE-X10 facility has been peformed under the assumption of partial loss of reactor and service pool water to assess the safety from the view point of design. Four photon source terms considered in the analysis were calculated using the ORIGEN-S code. Gamma dose rate calculations over the reactor and service pools during the water-loss accident conditions were performed using QAD-CG code. MCNP code (Monte Carlo Neuron and Photon Transport code), also, was used to assess the scattered radiation fields away from the pools, which is appropriate for calculating the scattered photon dose rates outside of the solid angle subtended by the source and pool walls.

  • PDF

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF