• Title/Summary/Keyword: 선원

Search Result 1,482, Processing Time 0.026 seconds

Langerhans Cell Histiocytosis in the Skull: Comparison of MR Image and Other Images (두개골의 랑게르한스 세포 조직구증: 자기공명영상과 다른 영상과의 비교)

  • Lim, Soo-Jin;Lim, Myung-Kwan;Park, Sun-Won;Kim, Jung-Eun;Kim, Ji-Hye;Kim, Deok-Hwan;Lee, Seok-Lyong;Suh, Chang-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Purpose : To evaluate the characteristic MR imaging findings of Langerhans cell histiocytosis (LCH) in the skull and to compare them with those of plain radiography and computed tomography. Materials and Methods : A total of 10 lesions in 9 patients (Age range; 5-42 years, Mean age; 18, all women) with Langerhans cell histiocytosis in the skull were included in our study. Nine lesions in nine patients were histologically confirmed by surgery or fine needle aspiration biopsy. All patients performed with MRI, and plain radiography and CT scan were done in 7 patients (8 lesions). Two experienced neuroradiologists reviewed the radiological examinations independently with attention to location, size, shape and nature of the lesions in the skull and compared the extent and extension of the lesions to adjacent structures. Results : The lesions were distributed in all of the skulls without predilection site. On MRI, the masses were shown as well-enhancing soft tissue masses (10/10) mainly in diploic spaces (8/10) with extension to scalp (9/10) and dura mater (7/10). Dural enhancement (7/10) and thickening (4/10) were seen. The largest diameter of the soft tissue masses ranged 1.1 cm to 6.8 cm, shaped as round (5/10) or oval (5/10). On CT scans, the lesions were presented as soft tissue masses involving diploic space (6/8) and scalp extension (7/8) were also well visualized. Although bony erosion or destruction was more clearly seen on CT rather than those of MRI, enhancement of soft tissue masses and dura were not well visualized on CT. In contrast, all of the lesions in LCH were seen as punched out (4/8), beveled-edge appearance (4/8) osteolytic masses in plain radiography, but scalp and dural extension could not be seen. Conclusion : Characteristic MR findings in patients with LCH are soft tissue mass in diploic space with extension to dura and scalp, and MRI would be better imaging modality than plain radiography or CT.

  • PDF

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

e-Navigation 관련 산업현황에 관한 기초연구

  • Choe, Han-Gyu;Gang, Byeong-Jae
    • 선박안전기술공단연구보고서
    • /
    • s.4
    • /
    • pp.1-108
    • /
    • 2007
  • 2007. 7. 23 IMO의 NAV(항해안전전문위원회)53차 회의에서는 e-Navigation을 해상에서의 안전, 보안, 해양환경보호를 목적으로 전자적인 수단에 의해 선박과 육상에서 해양정보를 수집, 교환, 표시함으로써 항구와 항구간의 항해 및 관련된 서비스를 향상시키는 것으로 정의하고 있다.2005년 11월 영국의 교통부 장관 Stephen 박사는 Royal Institute ofNavigation에서의 연설에서 해상안전과 환경보호를 위하여 선박의 항해를 감시하는 관제소 및 항행하는 선박에 유용하고 정확한 정보가 더 많이 필요함을 역설하였다. 그리고 첨단 기술에 의해 자동화된 항공 항법분야를 예로들면서, 선박의 항법 분야도 항해와 관련된 모든 시설 및 작업을 전자적 수단으로 대체하는 개념인 e-Navigation으로 전환되어야 하며 영국은 이에 필요한 작업을 주도하겠다는 의견을 피력하였다. Stephen은 e-Navigation 도입으로 얻을 수 있는 이익으로 첫째, 항해 실수로 인한 사고 확률저감, 둘째,사고 발생 시 인명 구조 및 피해 확산을 위한 효율적 대응, 셋째, 전통적인항해시설 설치 불필요로 인한 비용 저감, 넷째 선박입출항 수속의 간편화 및항로의 효율적 운용으로 인한 상업적 이익 등을 들었다. 반면에e-Navigation 체계로 전환 시 예상되는 장애로는 첫째, 체계 구축을 위한 비용(특히 개발도상국가들의 경우 어려움 예상), 둘째, e-Navigation의 성과 달성을 위하여 세계 전 해역의 모든 선박이 e-Navigation 체계에 동참하도록유도하는 문제, 셋째, 전자해도 표시 및 선교 장비들에 대한 표준화 문제, 넷째, 육상에 설치할 e-Navigation 센터의 설계 및 구축 등을 꼽았다.IMO는 2005년 81차 MSC(해사안전위원회) 회의에서 영국이 일본, 마샬아일랜드, 네덜란드, 노르웨이, 싱가포르, 미국과 공동으로 제안한 ‘e-Navigation전략 개발’ 의제를 2006년 82차 MSC 회의에서 채택하고, NAV(항해 전문위원회)를 통하여 2008년까지 e-Navigation의 구체적 개념을 정립하고 향후 개발하여야 할 전략적 비전과 정책을 수립하기로 하였다. 이어서 영국을 의장으로 e-Navigation 전략개발 통신작업반이 구성되었는데, 지난 년간 19개국, 16개 전문기관이 참여하여 아래의 작업이 수행되었다. ○ e-Navigation 개념의 정의와 목적 ○ e-Navigation에 대한 핵심 이슈 및 우선 순위 식별 ○ e-Navigation 개발에 따른 이점과 단점의 식별 ○ IMO 및 회원국 등의 역할 식별 ○ 이행계획을 포함한 추가 개발을 위한 작업계획의 작성 IMO에서 수행되고 있는 e-Navigation 전략 개발 의제 일정은 2008년까지이다. 이 전략 개발에 있어서 중요한 요소는 e-Navigation이 포함할 서비스범위, 포함하는 서비스 제공에 필요한 인프라 및 장비의 식별, 인프라 구축및 운용비용을 부담할 주체에 대한 논의, e-Navigation으로 인한 이익과 투자비용에 대한 비교 분석 등이다. 이 과정에서 정부, 선주, 항만운영자, 선원등의 입장 차이와 선진국과 개발도상국 간의 경제 수준 차이는 전략 개발에있어 큰 어려움을 줄 것이므로, 이들이 합의된 전략을 만들기 위해서는 예정된 기간보다 다소 늦어질 가능성도 있다.e-Navigation 전략 개발이 완료되면 1단계로는 해상교통 관제시스템, 선박선교 장비, 무선 통신장비 등에 대한 표준화 작업이 이루어질 것이다. 이 과정에서 각국 간에 자국 보유 기술을 표준화시키기 위한 경쟁이 치열할 것으로 예상된다. 2단계에서는 e-Navigation 체계 하에서의 다양하고 풍부한 서비스 제공을 위한 관련 소프트웨어 및 하드웨어의 개발이 이루어질 것으로전망되는데, 이는 지난 10년간 육상에서 인터넷망 설치 후 이루어진 관련 서비스 산업의 발전을 돌아보면 쉽게 짐작할 수 있을 것이다.e-Navigation 체계 하에서 선박의 항해는 현재와는 전혀 다른 패러다임으로 바뀔 것이다. 예를 들어 현재 입출항 시 요구되던 복잡한 절차는one-stop 쇼핑 형태로 단순화되고, 현재 선박 중심의 항해에서 육상e-Navigation 센터가 적극적으로 관여하는 항해 체계로 바뀔 것이며, 해상정보의 공유와 활용이 무선 인터넷을 통해 보다 광범위하게 이루어질 것이 다.e-Navigation의 잠재적 시장 규모는 선박에 새로이 탑재될 지능형 통합 항법시스템 구축과 육상 모니터링 및 지원 시스템 등 직접 시장이 약 50조원,전자해도, 통신장비, 관련 서비스 컨텐츠 등 간접 시장의 규모가 150조원으로 총 200조원으로 대략 추산하고 있다. 향후 이 거대한 시장을 차지하기 위한 전략 수립이 필요한 시점이다. 지금까지 항해 장비 관련 산업은 선진국의일부 업체들에 의해 독점되어 왔다. 우리나라는 조선과 해운에서 모두 선진국임에도 불구하고 이 분야에서는 대부분 수입에 의존해 왔다. e-Navigation체계 하에서는 전체 시장이 커지고 장비의 사양이 표준화됨에 따라 어느 소수 업체가 현재처럼 독점하기는 더 이상 어려울 것으로 예상된다. 따라서e-Navigation은 우리나라도 항해 장비 분야 시장을 차지할 수 있는 좋은 기회라고 할 수 있다. 특히 조선 1위의 장점을 적극 활용한다면 다른 나라보다우위의 경쟁력을 확보할 수도 있다. 또한, 서비스 분야의 시장은 IT 기술과밀접한 관계가 있으므로 IT 강국인 우리나라가 충분한 경쟁력을 갖고 있다고 할 수 있다.그러나, EU를 비롯한 선진국에서는 이미 e-Navigation 에 대비한 연구를10여년 전부터 수행해 왔다. 앞에서 언급한 EU의 MarNIS 사업은 현재 거의마무리 단계로 당장 실용화 할 수 있는 수준에 있는 것으로 보인다. 늦었지만 우리도 이를 따라잡기 위한 연구를 서둘러야 할 것이다. 국내에서도e-Navigation의 중요성을 깊이 인식하고, 2006년에는 관련 산학연 전문가들로 작업반을 구성하여 워크숍 등을 개최한 바 있다. 또한 해양수산부에서도e-Navigation 핵심기술 개발을 위한 연구사업을 기획 추진하고 있다.그러나 현재 항해통신장비들의 기술기준은 ITU의 전파규칙(RR)과 IMO결의 및 SOLAS 협약을 따르고 있는데 이들 규약이나 결의에 대한 국제적인 추이와 비교할 때 국내의 기술은 표준화되지 못한 부분이 많은 실정이다.본 연구에서는 e-Navigation sytem중 표준화가 필요한 요소와 전자해도,AIS 등 e-Navigation(통합전자항법시스템)관련 국내산업현황 실태조사를 통해 국내 e-Navigation기술개발 동향에 대해 조사하고자 한다.

  • PDF

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

Anti-wrinkle Activity of $\beta$-carotene Extracted & Purified from Recombinant Escherichia coli (재조합 대장균으로부터 추출.정제된 베타-카로틴의 주름개선 활성)

  • Jo, Ji-Song;Ku, Bo-Mi;Kang, Sang-Soo;Lee, Jae-Ran;Kim, You-Geun;Lee, He;Kim, Sung-Bae;Kim, Seon-Won;Kim, Chang-Joon;Chung, In-Young
    • KSBB Journal
    • /
    • v.23 no.6
    • /
    • pp.513-518
    • /
    • 2008
  • This paper described the extraction/purification of $\beta$-carotene from recombinant E.coli and evaluation of anti-wrinkle activity of purified $\beta$-carotene. No significant differences in extraction yields were observed when hexane or isobutyl acetate was used. However, extraction from wet-cell cake resulted in 2-fold higher amount of $\beta$-carotene than that from dry cells. Disruption of 5 g-wet cells by ultrasonic homogenizer, acetone dehydration, extraction with isobutyl acetate resulted in 36 mg of $\beta$-carotene corresponding to 61.2% of recovery. The formation and separation of $\beta$-carotene crystal improved the purity. 633 mg of $\beta$-carotene crystal with 93% purity was obtained from 223 g/L of wet-cell cake harvested from 2.5-L fed-batch culture broth. The cultures of normal human primary fibroblast were performed to investigate the effect of $\beta$-carotene on cytotoxicity as MTT assay and anti-wrinkle activity as collagen synthesis assays. $1.7{\mu}M$ of $\beta$-carotene was found to be optimal concentration at which 1.4-fold higher amount of collagen was synthesized than that in absence of $\beta$-carotene. This indicates that highly purified $\beta$-carotene can be obtained from recombinant E.coli by applying simple method with less toxic solvent and can be used in functional cosmetics as anti-wrinkle agent.

Analysis and the Standardization Plan of the Terms Used by Seafarers on Small Vessel (소형선박 종사자 사용용어 실태 분석 및 표준화 방안)

  • Kang, Suk-Young;Ryu, Won;Bae, Chang-Won;Kim, Jong-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.867-873
    • /
    • 2019
  • As of August 2019, there were 3,823 vessels under 30 tons that could be included in the category of small vessels; these account for 42.5 % of the 9,001 registered vessels in Korea. The problem is that many small vessel seafarers face many problems such as an board communication disconnection, difficulties in communication in maritime license interviews, or education related to maritime training using a large number of nonstandard terms, which are derived from foreign languages; this is leading to a decline the job skills of small vessel seafarers. Therefore, in this study, we closely analyzed the terminology of small vessel seafarers and proposed a standardization plan. In the terminology analysis, the preliminary terms of the maritime license interview and the high-frequency terms of the small vessel educational textbook were identified and the corresponding nonstandard terms were examined. Based on a survey, an expert meeting was held and incorrect Japanese notation, English notation, and the standard language for key terms were presented to analyze which questionnaire was most familiar. The ratio of the use of standard words is relatively high in the case of nautical terms, however, the wrong Japanese notation is used more for engine terms; the analysis results by age and tonnage also generally use the Japanese notation and the use frequency of English notation was determined to be low. Based on this, short- and long-term plans for the use of standard words by small vessel seafarers were proposed, including the production of a standard language dictionary for terms used by these seafarers, a promotion of the importance of using standard terms, active education through educational institutions, and the systematic preparation and implementation of Korean-language education for foreign sailors.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Radiation Therapy for Pituitary Adenoma -Changes in Endocrine Function after Treatment- (뇌하수체선종의 방사선치료후 혈중 호르몬치의 변화)

  • Yoon Sei Chul;Jang Hong Suck;Kim Song Hwan;Shinn Kyung Sub;Bahk Yong Whee;Son Ho Young;Kang Joon Ki
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.185-195
    • /
    • 1991
  • Seventy four patients with pituitary adenoma received radiation therapy (RT) on the pituitary area using 6 MV linear accelerator during the past 7 years at the Division of Radiation Therapy, Kangnam St. Mary's Hospital, Catholic University Medical College. Thirty nine were men and 35 were women. The age ranged from 7 to 65 years with the mean being 37 years. Sixty five ($88\%$) patients were treated postoperatively and 9 ($12\%$) primary RT, To evaluate the effects of RT, we analyzed the series of endocrinologic studies with prolactin (PRL), growth hormone (GH), adrenocorticotrophic hormone (ACTH), leuteinizing hormone (LH), follicular stimulating hormone (FSH) and thyroid stimulating hormone (TSH) etc after RT. All but one with Nelson's syndrome showed abnormal neuroradiologic changes in the sella turcica with invasive tumor mass around supra- and/or parasella area. The patients were classified as 23 ($29\%$) prolactinomas and 20 ($26\%$) growth hormone (GH) secreting tumors, and 6 ($8\%$ ACTH secreting ones consisting of 4 Cushing's disease and 2 Nelson's syndrome. Twentynine ($37\%$) had nonfunctioning tumor and four ($5\%$) of those secreting pituitary tumors were mixed PRL-GH secreting tumors. The hormonal level in 15 ($65\%$) of 23 PRL and 3 ($15\%$) of 20 GH secreting tumors returned to normal by 2 to 3 years after RT, but five PRL and five GH secreting tumors showed high hormonal level requiring bromocriptine medication. Endocrinologic insufficiency developed by 3 years after RT in 5 of 7 panhypopituitarisms, 4 of seven hypothyroidisms and one of two hypogonadisms, respectively. Fifteen ($20\%$) patients were lost to follow up after RT.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.