• Title/Summary/Keyword: 선박발전기

Search Result 109, Processing Time 0.026 seconds

Electromagnetic Interference of GMDSS MF/HF Band by Offshore Wind Farm (해상풍력 발전단지에 의한 GMDSS MF/HF 대역 전자파 간섭 영향 연구)

  • Oh, Seongwon;Park, Tae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Recently, the share of wind power in energy markets has sharply increased with the active development of renewable energy internationally. In particular, large-scale wind farms are being developed far from the coast to make use of abundant wind resources and to reduce noise pollution. In addition to the electromagnetic interference (EMI) caused by offshore wind farms to coastal or air surveillance radars, it is necessary to investigate the EMI on global maritime distress and safety system (GMDSS) communications between ship and coastal stations. For this purpose, this study investigates whether the transmitted field of MF/HF band from a ship would be subject to interference or attenuation below the threshold at a coastal receiver. First, using geographic information system digital maps and 3D CAD models of wind turbines, the area of interest is electromagnetically modeled with patch models. Although high frequency analysis methods like Physical Optics are appropriate to analyze wide areas compared to its wavelength, the high frequency analysis method is first verified with an accurate low frequency analysis method by simplifying the surrounding area and turbines. As a result, the received wave power is almost the same regardless of whether the wind farms are located between ships and coastal stations. From this result, although wind turbines are large structures, the size is only a few wavelengths, so it does not interfere with the electric field of MF/HF distress communications.

Effect Analysis of Offshore Wind Farms on VHF band Communications (VHF 대역 통신에 대한 해상풍력 발전단지의 영향성 분석)

  • Oh, Seongwon;Park, Taeyong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.307-313
    • /
    • 2022
  • As the development of renewable energy expands internationally to cope with global warming and climate change, the share of wind power generation has been gradually increasing. Although wind farms can produce electric power for 24 h a day compared to solar power plants, Their interfere with the operation of nearby radars or communication equipment must be analyzed because large-scale wind power turbines are installed. This study analyzed whether a land radio station can receive sufficient signals when a ship sailing outside the offshore wind farm transmits distress signals on the VHF band. Based on the geographic information system digital map around the target area, wind turbine CAD model, and wind farm layout, the area of interest and wind farm were modeled to enable numerical analysis. Among the high frequency analysis techniques suitable for radio wave analysis in a wide area, a dedicated program applying physical optics (PO) and shooting and bouncing ray (SBR) techniques were used. Consequently, the land radio station could receive the electromagnetic field above the threshold of the VHF receiver when a ship outside the offshore wind farm transmitted a distress communication signal. When the line of sight between the ships and the land station are completely blocked, the strength of the received field decreases, but it is still above the threshold. Hence, although a wind farm is a huge complex, a land station can receive the electromagnetic field from the ship's VHF transmitter because the wave length of the VHF band is sufficiently long to have effects such as diffraction or reflection.

A Study on the Development of Shaft Power Measuring System (축계 마력 측정 시스템의 개발에 관한 연구)

  • Nam, T.K.;Lee, D.C.;Roh, Y.O.;Heo, G.S.;Choi, G.J.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.213-216
    • /
    • 2006
  • In this paper a development of shaft power measuring system for a small vessel is discussed. It is important that the exact power measurement of marine engine which is used for ship's propulsion since the engine power is related to ship's usage and its shaft design. Two gearwheel and magnetic sensors are adopted to measure torsional angle on the shaft. High resolution encoder is also applied to compensate the output signal from gearwheel. The calculation of shaft power is executed using measured signal and angular velocity of rotating machine and the result is plotted on the monitoring screen.

  • PDF

Improvement of combustion efficiency for marine auxiliary diesel engine (선박발전기용 디젤엔진의 연소효율 개선에 관한연구)

  • Jung, Kyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.233-239
    • /
    • 2014
  • The accurate engine output is basically one of important factors for the analysis of engine performance. Nowadays in-cylinder pressure analyzer in internal combustion engine is also an indispensable tool for engine research and development, environment regulation and maintenance of engine. The combustion analysis is desperately needed in order to induce a correct judgment on the condition of the engine and suggest the specific ways to improvement as well as the correct engine output. And these tool is advantageous to reduce fuel consumption and maintenance of the engine. In this study, using the developed measuring kit, combustion analysis of marine generator engine which was adapted as test engine was carried out. It was verified that the good operation condition of the engine as well as contributing to fuel savings by checking and readjusting accurately the irregular combustion of the test engine were accomplished. From the results all above, it was recognized that the measuring kit by new method for engine output was developed and verified for its utilities.

The Relative Position Estimate of the Moving Distributed Sources Using the Doppler Scanning Technique (도플러 스캐닝 기법을 이용한 이동하는 다중 음원의 상대 위치 추적 기법)

  • 노용주;윤종락;전재진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.446-454
    • /
    • 2002
  • This paper presents the Doppler Scanning technique which enables us to detect the relative positions of moving distributed sources using Doppler frequency shift estimate when the moving source consists of distributed sources with different signature frequencies. Doppler frequency shifts of characteristic frequencies of machinery noise sources such as ship's generator and propeller, with tine along CPA (Closest Point of Approach of moving source) are unique, and can be functioned with respect to each source position. Therefore, this technique can be applied to estimate the relative geometrical positions between machinery noise sources. The Extended Kalman Filter (EKF) which has a high frequency resolution with high time resolution, is adopted for improving accuracy of Doppler frequency shift estimate geometric resolution of machinery positions since machinery noise sources show in general low frequency band characteristics with limited spacial distance. The performance of the technique is examined by the numerical simulations and is verified by the experiment using loudspeaker sources on the roof of the car.

A Study on the Propeller Thrust for a Moored Ship (계류중인 선박의 프로펠러 추력 추정에 관한 연구)

  • Ha, M.K.;Song, I.H.;Kim, D.J.;Wee, K.S.;Kim, S.W.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.1
    • /
    • pp.50-59
    • /
    • 1997
  • Shipbuilder checks the status of main engine and propeller operation before sea trial. Generally these tests are carried out at a quay during fitting out of the ship. For these tests the operator has to estimate the maximum RPM with permissible torque and thrust to ensure the safety of the mooring line and ship. In this paper, the propeller characteristics according to the draft variation for a moored ship is inveatigated. From these tests, it is shown that shaft submergence is a dominant parameter in the propeller performance at shallow shaft submergence and that the propeller performance is dependent upon the propeller RPM when the shaft submergence is kept unchanged. In this study, a simple formula of the required thrust for a given propeller shaft submergence and propeller RPM is derived. 1be propeller thrust, which is calculated by another formula in case of dtep draft, is compared with results of bollard pull test for FPSO.

  • PDF

1MVA synchronous generator control for vessel used for digital AVR of drop method (Drop 방식의 디지털 AVR을 이용한 1MVA급 선박용 동기발전기 제어)

  • Yoo, Dong-Hwan;Hwang, Chun-Hwan;Park, Sang-Hoon;Yoo, Jae-Sung;Lee, Sang-Suk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.225-229
    • /
    • 2007
  • The output voltage of a synchronous generator is regulated constantly by field current control of excitation system. Synchronous generator exciter has two type, first one is Drop control type by thyristor and second one is exciter current control type through power output by PWM control. Control method of the second one prevails, but when the power devices have a breakdown, output voltage of the generator rises rapidly. This exciter must have a protection circuit and system is complicated, so reliability is poor Excitation control type which is drop control type control only 10% of the power, so it can be improved precision. When a trouble come to the controller, output voltage of a generator don't rise excessively and the voltage rise about 10%, so it has a excellent reliability. This paper prove stability of the digital AVR.

  • PDF

Voltage Control of a Synchronous Generator for Ship using a Compound Type Digital AVR (혼합형 디지털 자동 전압 조정 장치를 이용한 선박용 동기발전기의 출력전압제어)

  • Park, Sang-Hoon;Lee, Sang-Seuk;Yu, Jae-Sung;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.397-403
    • /
    • 2009
  • In this paper, an exciter current control of a synchronous generator for ships using a compound type digital automatic voltage regulator (DVAR) in order to provide a constant output voltage of the generator is presented. The compound type DAVR is composed of a controller part to adjust output voltage and an power source unit to supply power to the exciter. The controller part, which generates the PWM switching pattern via the PI controller, drives a power MOSFET for bypass to limit the SG's exciter current. The power source unit part is parallel connected to an output terminal of the generator through a reactor and a power CT. The residual magnetic flux of SG provides exciter current to the exciter through the reactor during the initial running or no load state and load current supplies field current to the exciter through the power CT during loading state. This paper confirmed an experiment to verify the validity of compound type DAVR system for controlling output voltage of synchronous generator.

Voltage Control of Synchronous Generator for Ship Using a PMG Type Digital AVR (PMG Type 디지털 AVR을 이용한 선박용 동기발전기 출력전압제어)

  • Yu, Dong-Hwan;Park, Sang-Hoon;Yu, Jae-Sung;Lee, Sang-Suk;Kim, Young-Real;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.136-138
    • /
    • 2008
  • The output voltage of synchronous generator is regulated constantly by field current control in excitation system. Most of ship generator exciter system uses the thyristor phase controlled rectifier. However this rectifier is difficult to realize that the speed control system because its control period is slower than MOSFET and IGBT type converter. Therefore, this paper deals with PMG(Permanent Magnet Generator) type digital excitation system using MOSFET for ship synchronous generator. The organization of this excitation system is very simple. When the generator is under the short circuit accident, the output voltage becomes zero state and AVR can not operate. Thus generator requires the function for flowing output current through CBS. The performance of the proposed system is evaluated on a 10kVA experimental prototype circuit in place of real ship generator.

  • PDF

Robust Adaptive Voltage Control of Electric Generators for Ships (선박용 발전기 시스템의 강인 적응형 전압 제어)

  • Cho, Hyun Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.5
    • /
    • pp.326-331
    • /
    • 2016
  • This paper presents a novel robust adaptive AC8B exciter system against synchronous generators for ships. A PID (proportional integral derivative) control framework, which is a part of the AC8B exciter system, is simply composed of nominal and auxiliary control configurations. For selecting these proper parameter values, the former is conventionally chosen based on the experience and knowledge of experts, and the latter is optimally estimated via a neural networks optimization procedure. Additionally, we propose an online parameter learning-based auxiliary control to practically cope with deterioration of control performance owing to uncertainty in electric generator systems. Such a control mechanism ensures the robustness and adaptability of an AC8B exciter to enhance control performance in real-time implementation. We carried out simulation experiments to test the reliability of the proposed robust adaptive AC8B exciter system and prove its superiority through a comparative study in which a conventional PID control-based AC8B exciter system is similarly applied to our simulation experiments under the same simulation scenarios.