• Title/Summary/Keyword: 선로조건

Search Result 199, Processing Time 0.026 seconds

Analysis on the Dynamic Behavior according to Suspension Structure of the Urban Railway Vehicle (전동차 현가구조에 따른 동적거동특성 분석)

  • Hur, Hyun-Moo;Noh, Hak Rak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.617-623
    • /
    • 2020
  • Urban railroad vehicles carry many passengers and are the core of an urban railroad transportation system. Therefore, the dynamic performance of the vehicle must be ensured. Dynamic behaviors such as the vibration and ride comfort of railway vehicles are affected by the structure of the suspension system. We analyzed the dynamic behavior of a railway vehicle according to the suspension system of an urban railway vehicle, which is mainly operated in Korea. For two types of vehicles with different suspension structures, the vibration of the vehicles on railway tracks was measured, and dynamic behavior characteristics such as vibration, ride, and vibration reduction rate were analyzed. The result of the test shows that the vibration performance of the body is superior to that of B-bogie in the lateral direction and that of A-bogie in the vertical direction. Overall, the ride quality of the A-bogie car is superior to that of B-bogie. When analyzing the vibration attenuation rate of primary suspension system, the vibration attenuation performance of B-bogie with coil spring was superior to that of A-bogie with a conical rubber spring. The secondary suspension system has better vibration attenuation performance for A-bogie with air springs compared to coil springs.

Simulation for characteristics of various type SFCLs (유형별 초전도 한류기의 특성에 대한 시뮬레이션)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon;Han, Byoung-Sung
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.338-342
    • /
    • 1999
  • We simulated the current limiting characteristics of resistive and inductive SFCLs with 100 ${\omega}$ of impedances for a single and double line-to-ground faults in the 154 kV grid between two substations nearby Seoul. The transient current at the faults includes not. only high AC current up to 44 kA but also significant DC component as high as 4 kA. The DC current is greater and lasts longer for the double line-to-ground fault than for the single line-to-ground fault. The inductive SFCL limited the fault current more effectively than the resistive one. The DC component, however, was greater and diminishes slower for the inductive SFCL than for the resistive one.

  • PDF

Characteristics of Microwave Air Plasma With a Wide Range of Operating Pressures (운전압력 변화에 따른 마이크로파 공기 플라즈마의 특성연구)

  • 조정현;장봉철;박봉경;김윤환;정용호;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.1
    • /
    • pp.68-75
    • /
    • 2002
  • It is observed the characteristic of the microwave air plasma in the wide range of the operating pressure, 1 mTorr ~ 760 Torr. The microwave air plasma was generated by an AC-type microwave source manufactured with a magnetron taken from a commertial microwave oven and the input power was fixed at 370 W. Characteristics of the plasmas were observed by an injection Langmuir probe and an OES(Optical Emission Spectroscopy). The breakdown electric field is drastically changed at 500 mTorr. For < 500 mTorr, the ratio of the breakdown electric field and the pressure decreased inversely to the pressure, $5.7\times10^4$V/m-Torr.However, the ratio increased linearly as 43 V/m-Torr for the operating pressure, > 500 mTorr. The minimum breakdown electric field was observed about 12. kV/m at 500 mTorr. It corresponds that the input frequency equals to the collision frequency. The effective collision cross section of the air at this pressure was calculated as $9.23\times10^{-l6}\textrm{cm}^2$.The results of the OES measurement revealed that the main ions were composed of the oxygen, argon, and nitrogen for > 500 mTorr. In contrast, only oxygen and argon ions were dominated for < 500 mTorr. ion temperature of oxygen (O(II)) in the air was decreased from about 1.2 eV to 0.5 eV as the pressure increased. Langmuir probe data shows that the plasma density for < 500 mTorr was higher that for > 500 mTorr.

Analysis of Factors Influencing upon the Metro Wear Using the Classification and Regression Trees (CART 분석을 이용한 지하철 마모 영향인자 분석)

  • Jeong, Min Chul;Lee, Won Woo;Kim, Jung Hoon;Kong, Jung Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.38-38
    • /
    • 2011
  • 일반적으로 레일마모는 열차의 주행안전 및 승차감에 미치는 영향이 크고, 소음 진동의 주요원인으로 작용한다. 또한 레일마모가 발생할 경우 궤도구조의 파괴를 촉진시킴으로써 차량 및 궤도유지보수비를 크게 증가시킨다. 따라서 구간 특성 및 환경 영향 인자 등 현장에서 발생하는 마모 원인을 체계적으로 분석함으로써 마모를 저감할 수 있도록 차량운행 조건과 선로선형 및 궤도구조를 설계하는 것은 중요한 과제이다. CART(Classification And Regression Tree; 분류와 회귀나무) 분석은 패키지화된 좋은 분류 및 예측도구 기법으로 나무의 상위 분리수준에서 일반적으로 나타나는 가장 중요한 입력변수들을 사용하는 등의 입력변수를 선정하는 경우 매우 유용하다. 본 연구에서는 다변수 구간특성 및 환경인자를 고려한 검측 자료 상관관계 분석을 위한 회귀 나무기반 모델(TBM: Tree Based Model) 분석 수행을 위해 지하철 2호선 마모 데이터와 마모 데이터에 영향을 미치는 각종 다변수 구간특성 및 환경인자를 사용하였다. 2호선 지하철의 구간특성 인자 및 환경인자는 레일의 종류, 레일의 위치, 도상, 곡률반경, 캔트 슬랙 및 운행 일수 등으로 구분하였다. 레일의 종류는 ks-50kg과 ks-60kg 두 종류의 레일이 있으며, 레일의 위치는 지상과 지하로 크게 구분할 수 있다. 도상은 콘크리트 도상, 자갈 도상과 일부 구간의 방진상 콘크리트 도상으로 구분할 수 있으며, 곡률반경은 직선구간과 완화곡선 구간 및 최소 250m부터 627m까지 분포된 원 곡선 구간으로 구분할 수 있다. 캔트 간격은 최소 96cm 부터 120cm 간격으로 구분하며, 슬랙은 5~9cm에 분포하고, 운행 기간은 해당 기간 동안 유지보수 이력이 없는 구간을 선정하여 2005년부터 2006년까지 4번에 걸쳐 검측된 지하철 2호선 내선 마모데이터를 사용하였다. 총 X1부터 X7까지 총 7개의 구간특성 또는 환경특성을 영향인자로 선정하였으며, 이러한 영향인자에 의해 결정되는 종속 인자로 Y1인 직마모와 Y2인 측마모를 선정하여 이 중 실질적으로 지하철 궤도의 성능 평가에 주요 판단인자로 사용되는 측마모와 구간특성 및 환경영향인자와의 상관관계 분석을 수행하였다. 해당 마모 데이터가 검측되는 기간 동안 유지보수 이력이 없는 12272 point의 데이터를 검출하였고 CART 프로그램을 이용하여 데이터를 분석하였으며, CART 프로그램의 해석을 위해 종속변수인 직마모량은 각 검측 지점의 마모량에 해당하는 등급으로 변환하여 분석을 수행하였다. 레일의 마모에 영향을 미치는 구간특성 및 환경인자와 종속 변수로 사용된 레일의 마모량 사이의 CART를 이용한 상관관계 분석은 실제 구조물에서 영향인자간의 상관 관계와 유사하며, 추후 연구에서는 이를 바탕으로 하여 정량화된 검측 데이터를 종속변수로 하여 구간특성 또는 환경인자 등 외부 영향인자를 고려한 궤도 검측데이터와의 상관관계 분석을 수행할 계획이다.

  • PDF

The Design and Characteristics of the Inductive Coupler Using the Nanocrystalline Materials (나노 결정립 재료를 이용한 비접촉식 커플러의 설계 및 특성)

  • Kim, Jong-Ryung;Kim, Hyun-Sik;Huh, Jeong-Sub;Lee, Hae-Yeon;Lee, Jun-Hui;Oh, Young-Woo;Byun, Woo-Bong
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.6
    • /
    • pp.300-304
    • /
    • 2006
  • The varied heating temperatures were used for magnetic core materials, which nano sized ${\alpha}-Fe$ crystalline was created in nanocrystalline Fe-Si-B-Nb-Cu materials, with hish permeability and low power loss. The highest permeability and lowest power loss were obtained to the specimen heat-treated at $510^{\circ}C$. The signal transmission characteristics of inductive coupler, which was manufactured by using the magnetic core materials prepared in this study, at low frequency range, was influenced strongly by magnetic property of magnetic core materials as this result is corresponding to the permeability as a function of heat treatment temperature, as well, it was improved by impedance matching at high frequency range. Over $500{\mu}m$ of air gap in coupler is required to maintain the magnetic properties without magnetic saturation on the subterranean line transferred hish current of 300 A. The inductive coupler for PLC, which has an attenuation characteristics of less than 5dB, was manufactured using nano-crystalline magnetic core materials through the above mentioned research results.

Current Limiting and Recovery Characteristics of Two Magnetically Coupled Type SFCL with Two Coils Connected in Parallel Using Dual Iron Cores (이중철심을 이용한 병렬연결된 자기결합형 초전도한류기의 전류제한 및 회복특성)

  • Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.717-722
    • /
    • 2016
  • In this paper, in order to support the peak current limiting function depending on the intensity of the fault current at the early stage of failure, a two magnetically coupled type superconducting fault current limiter (SFCL) is proposed, which includes high-Tc superconducting (HTSC) element 1, where the existing primary and secondary coils are connected to one iron core in parallel, and HTSC element 2, which is connected to the tertiary winding using an additional iron core. The results of the experiments in this study confirmed that the two magnetic coupling type SFCL having coil 1 and coil 2 connected in parallel using dual iron cores is capable of having only HTSC element 1 support the burden of the peak current when a failure occurs. The reason for this is that although HTSC element 1 was quenched and malfunctioned because the instantaneous factor of the initial fault current was large, the current flowing to coil 3 did not exceed the critical current, which would otherwise cause HTSC element 2 to be quenched and not function. In order to limit the peak current upon fault through the sequential HTSC elements, the design should allow it to have the same value as the low value of coil 1 while having coil 3 possess a higher self-inductance value than coil 2. In addition, a short-circuit simulation experiment was conducted to examine and validate the current limiting and recovery characteristics of the SFCL when the winding ratio between coil 1 and coil 2 was 0.25. Through the analysis of the short-circuit tests, the current limiting and recovery characteristics in the case of the additive polarity winding was confirmed to be superior to that of the subtractive polarity winding.

Research on Vibration and Noise Characteristics of Steel Plate Girder Bridge with Embedded Rail Track System (레일매립궤도 시스템이 적용된 판형교의 진동 및 소음특성에 대한 연구)

  • Park, Jeung-Geun;Koh, Hyo-In;Kang, Yun-Suk;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.94-101
    • /
    • 2019
  • Most of the existing rail structures have undergone a lot of aging since a considerable period of time has passed from completion. In particular, among existing railway bridges, many of the plate girder bridges are older bridges that have lived 40 to 60 years or more. Since the treadmill is directly connected to the girder without the ballast, the running load of the vehicle is directly transmitted to the bridge. Therefore, the shock and noise applied to the bridge are larger than those of the ballast bridge, and the dynamic shock and vibration are also relatively large. Therefore, it is very urgent to develop appropriate maintenance, repair and reinforcement technology for existing steel plate bridge. In this study, the authors introduced the characteristics of embedded rail (ERS) developed for improving the performance of the existing plate girder bridge and the techniques solving the vibration and noise problems. In order to evaluate the vibration and noise reduction performance of ERS, a non-ballast plate girder bridge with 5m length of sleepers installed and a plate girder bridge with ERS were fabricated. And, then, the vibration response generated under the same excitation condition was measured and analyzed. Also, the radiated noise analysis was performed using the vibration response data obtained from the experiment as the input data of the acoustic analysis model. As a result of experiments and analyses, it was confirmed that the plate girder bridge's vibration using ERS was reduced by 15.0~18.8dB and the average noise was reduced by 7.7dB(A) more than the non-ballast bridge.

Estimation of installation spacing by analyzing the lateral behavior of the safety fence fixed to rail bottom (레일저부고정형 안전펜스의 횡 방향 거동 분석을 통한 설치간격 산정)

  • Park, Seonghyeon;Sung, Deokyong;Lee, Changho;Jung, Hyuksang;Youg, Seungkyong
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.249-257
    • /
    • 2018
  • The number of deaths for railway traffic accidents is mainly caused by working close to the track, or when unauthorized passage pass through the track. The safety fences are being used to ensure safety for workers close to the track, and to improve the efficiency of the work, without interfering with the passage of trains. However, a safety fence for railway tracks needs to be examined to see if it will interfere with the passage of trains. The purpose of this study is to analyze the safe distance between train and safety fence developed in Korea. In addition, the lateral load condition of wind pressure by trains is estimated and numerical analysis is carried out according to the installation intervals of railway safety fences. It has been confirmed that the proper spacing between the train and the railway safety fence should be at least 200 mm from the vehicle limit, and that the proper spacing of railway safety fence must be calculated in consideration of the wind pressure by trains.

A Study on Machine Learning-Based Real-Time Automated Measurement Data Analysis Techniques (머신러닝 기반의 실시간 자동화계측 데이터 분석 기법 연구)

  • Jung-Youl Choi;Jae-Min Han;Dae-Hui Ahn;Jee-Seung Chung;Jung-Ho Kim;Sung-Jin Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.685-690
    • /
    • 2023
  • It was analyzed that the volume of deep excavation works adjacent to existing underground structures is increasing according to the population growth and density of cities. Currently, many underground structures and tracks are damaged by external factors, and the cause is analyzed based on the measurement results in the tunnel, and measurements are being made for post-processing, not for prevention. The purpose of this study is to analyze the effect on the deformation of the structure due to the excavation work adjacent to the urban railway track in use. In addition, the safety of structures is evaluated through machine learning techniques for displacement of structures before damage and destruction of underground structures and tracks due to external factors. As a result of the analysis, it was analyzed that the model suitable for predicting the structure management standard value time in the analyzed dataset was a polynomial regression machine. Since it may be limited to the data applied in this study, future research is needed to increase the diversity of structural conditions and the amount of data.