• Title/Summary/Keyword: 선량 확인

Search Result 1,101, Processing Time 0.035 seconds

The Results of Postoperative Radiotherapy for Hypopharyngeal Carcinoma (하인두암 환자에서의 수술 후 방사선치료의 결과)

  • Kim Won Taek;Ki Yong Kan;Nam Ji Ho;Kim Dong Won;Lee Byung Ju;Wang Su Gun;Kyuon Byung Hyun
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.254-264
    • /
    • 2004
  • Purpose: This study was carried out to confirm clinical values and limitations of postoperative radiotherapy for hypopharyngeal carcinoma, to evaluate various prognostic factors which may affect to the treatment results and to use these results as fundamental data for making a new treatment strategy. Methods and Materials:. A retrospective analysis was peformed on 64 previously untreated patients with squamous cell carcinoma of the hypopharynx, seen between 1988 and 1999 at Pusan National University Hospital. Most of patients were treated by laryngopharyngectomy and neck dissection followed by conventional fractionated postoperative radiotherapy on surgical bed and cervical nodal areas. Results: The five-year overall survival rate and cause-specific survival rate were 42.2 percent and 51.6 percent, respectively. Univariate analysis of various clinical and pathologic factors confirmed the overall stage, TN-stage, secondary primary cancers, surgical positive margin, nodal extracapsular extension, total radiation doses as significant prognostic factors of hypopharyngeal carcinomas. But in multivariate analysis, TN-stage, surgical positive margin and extracapsular extesion were only statistically significant. Conclusion: In resectable cases of hypopharyngeal carcinoma, combined surgery and postoperative radio-therapy obtained good treatement results, even though sacrificing the function of larynx and pharynx. But in advanced and unresectable cases, with respect to survivals and qualify of life issues, we were able to confirm some limitations of combined therapy. So we recommend that comparative studies of recent various chemo-radiotherapy methods and advanced radiotherapy techniques with these data should be needed.

Surgical Outcome of Patients with Ischemic Cardiomyopathy Selected by the Results of Myocardial Viability by Preoperative F-18 FDG PET (F-18 FDG 양전자단층촬영을 이용한 생존심근 평가 후 수술한 허혈성 심근병증 환자의 수술 결과)

  • Kim, Jae-Sung;Lee, Dong-Soo;Hong, Suk-Keun;Lee, Young-Tak;Kim, Yu-Kyeong;Kim, Youn-Jung;Moon, Keon-Sik;Won, Tae-Kyoung;Hwang, Hweung-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • Purpose: We investigated the operative outcome after bypass surgery in patients selected using viability criteria on F-18 FDG PET. Materials and Methods: Rest-24hr delay redistribution imaging of Tl-201 SPECT and F-18 FDG PET were performed in 11 patients. Seven of these 11 patients (6 men, 1 woman) were evaluated to have viable myocardium by F-18 FDG PET. Changes in symptoms and left ventricular ejection fraction (LVEF) after operation were evaluated. Results: In seven of 11 patients, a significant amount of viable myocardium was found on F-18 FDG PET and Tl-201 SPECT. Severity of both chest pain and dyspnea improved markedly in all patients. Mean LVEF improved from 22% to 32%. Conclusion: F-18 FDG PET could be used to select the patients who will benefit from coronary artery bypass surgery.

  • PDF

Studies on sterile filters in the preparation of N-13 ammonia injection (N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가)

  • Oh, Chang Bum;Kim, Si Hwal;Cha, Min Jung;Shin, Jin;Ji, Yong Gi;Choi, Sung Ook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2019
  • Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.

Effects for Growth and Chlorophyll in Old-barley and New-barley Seed exposed by X-ray (X-선이 묵은보리 씨앗과 햇보리 씨앗의 생장과 클로로필 농도에 미치는 영향)

  • Sang-Bok, Jeong;Sun-Cheol, Jeong;Mo-Kwon, Lee;Yun-Ho, Choi;Kang-Un, Byun;Su-Ah, Yu;Sang-Eun, Han;Jun-Beom, Heo;Wan-Sik, Shin;Won-Jeong, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • The purpose of this study is to compare of growth and chlorophyl between old-barley seed (OBS, 2019) and New-barley seed (NBS, 2020) exposed by X-ray. After germination the OBS and NBS, experimental group was exposed by 30 Gy X-ray using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18 × 10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) after measuring weight in 9th day. Data analysis was performed the Independent T-test using SPSS ver 26.0(Chicago, IL, USA). NBS grow more faster than OBS in control group, but OBS grow more faster than NBS in experimental group. Length of control group was longer significantly every day than that of experimental group in OBS. NBS weighted more than OBS in control group, but OBS weighted more than NBS in experimental group. In comparing chlorophyl density, NBS high more than OBS in control group as well as experimental group. Growth and weight of OBS was effected more those than NBS by X-ray, but NBS in chlorophyl by X-ray. It is expected to be used as basic data for future X-ray research in barley seed.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Combined Chemotherapy and Radiation Therapy in Limited Disease Small-Cell Lung Cancer (국한성 소세포 폐암에서 항암 화학 및 흉부 방사선치료의 병합요법 적응)

  • Kim Moon Kyung;Ahn Yong Chan;Park Keunchil;Lim Do Hoon;Huh Seung Jae;Kim Dae Yong;Shin Kyung Hwan;Lee Kyu Chan;Kwon O Jung
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • Purpose : This is a retrospective study to evaluate the response rate, acute toxicity, and survival rate of a combined chemotherapy and radiation therapy in limited disease small cell lung cancer, Materials and Methods : Firty-six patients with limited disease small-cell lung cancer who underwent combined chemotherapy and radiation therapy between October 1994 and April 1998 were evaluated. Six cycles of chemotherapy were planned either using a VIP regimen etoposide, ifosfamide, and cis-platin) or a EP regimen (etoposide and cis-platin). Thoracic radiation therapy was planned to deli- ver 44 Gy using 1 OMV X-ray, starting concurrently with chemotherapy. Response was evaluated 4 weeks after the completion of the planned chemotherapy and radiation therapy, and the prophylaetic cranial irradiation was planned only for the patients with complete responses. Acute toxicity was evaluated using the SWOG toxicity criteria, and the overall survival and disease-free survival were calculated using the Kaplan-Meier Method. Results : The median follow-up period was 16 months (range:2 to 41 months). Complete response was achieved En 30 (65$\%$) patients, of which 22 patients received prophylactic cranial irradiations. Acute toxicities over grade III were granulocytopenia in 23 (50$\%$), anemia in 17 (37$\%$), thrombo- cytopenia in nine (20$\%$), alopecia in nine (20$\%$), nausea/vomiting in five (11$\%$), and peripheral neuropathy in one (2$\%$). Chemotherapy was delayed in one patient, and the chemotherapy doses were reduced in 58 (24$\%$) out of the total 246 cycles. No radiation esophagitis over grade 111 was observed, while interruption during radiation therapy for a mean of 8.3 days occurred in 21 patients. The local recurrences were observed in 8 patients and local progressions were in 6 patients, and the distant metastases in 17 patients. Among these, four patients had both the local relapse and the distant metastasis. Brain was the most common metastatic site (10 patients), followed by the liver as the next common site (4 patients). The overall and progression-free survival rates were 79$\%$ and 55$\%$ in 1 year, and 45'/) and 32% in 2 years, respectively, and the median survival was 23 months. Conclusion : Relatively satisfactory local control and suwival rates were achieved after the combined chemotherapy and radiation therapy with mild to moderate acute morbidities in limited disease small cell lung cancer.

  • PDF

Outcomes after Radiotherapy in Inoperable Patients with Squamous Cell Lung Cancer (수술이 불가능한 편평상피성 폐암의 방사선치료 성적)

  • Ahn Sung-Ja;Chung Woong-Ki;Nah Byung-Sik;Nam Tack-Keun;Kim Young-Chul;Park Kyung-Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.216-223
    • /
    • 2001
  • Purpose : We evaluated retrospectively the outcomes of inoperable squamous cell lung cancer patients treated with radiotherapy to find out prognostic factors affecting survival. Materials and methods : Four hundred and eleven patients diagnosed as squamous cell lung cancer between November 1988 and December 1997 were the basis of this analyses. The planned dose to the gross tumor volume was ranged from 30 to 70.2 Gy. Chemotherapy was combined in 72 patients $(17.5\%)$ with the variable schedule and drug combination regimens. Follow-up period ranged from 1 to 113 months with the median of 8 months and survival status was identified in 381 patients $(92.7\%)$. Overall survival rate was calculated using the Kaplan-Meier method. Results : Age ranged from 23 years to 83 years with the median 63 years. The male to female ratio was about 16:1. For all 411 patients, the median overall survival was 8 months and the 1-year survival rate (YSR), 2-YSR, and 5-YSR were $35.6\%,\;12.6\%,\;and\;3.7\%$, respectively. The median and 5-YSR were 29 months and $33.3\%$ for Stage IA, 13 months and $6.3\%$ for Stage IIIA, and 9 months and $3.4\%$ for Stage IIIB, respectively(p=0.00). The median survival by treatment aim was 11 months in radical intent group and 5 months in palliative, respectively (p=0.00). Of 344 patients treated with radical intent, median survival of patients (N=247) who received planned radiotherapy completely was 12 months while that of patients (N=97) who did not was 5 months (p=0.0006). In the analyses of the various prognostic factors affecting to the survival outcomes in 247 patients who completed the planned radiotherapy, tumor location, supraclavicular LAP, SVC syndrome, pleural effusion, total lung atelectasis and hoarseness were statistically significant prognostic factors both in the univariate and multivariate analyses while the addition of chemotherapy was statistically significant only in multivariate analyses. The acute radiation esophagitis requiring analgesics was appeared in 49 patients $(11.9\%)$ and severe radiation esophagitis requiring hospitalization was shown in 2 patients $(0.5\%)$. The radiation pneumonitis requiring steroid medication was shown in 62 patients $(15.1\%)$ and severe pneumonitis requiring hospitalization was occurred in 2 patients $(0.5\%)$. During follow-up, 114 patients $(27.7\%)$ had progression of local disease with 10 months of median time to recur (range : $1\~87\;months$) and 49 patients $(11.9\%)$ had distant failure with 7 months of median value (range : $1\~52\;months$). Second malignancy before or after the diagnosis of lung cancer was appeared in 11 patients Conclusion : The conventional radiotherapy in the patients with locally advanced squamous cell lung cancer has given small survival advantage over supportive care and it is very important to select the patient group who can obtain the maximal benefit and to select the radiotherapy technique that would not compromise the life quality in these patients.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

HW/SW Partitioning Techniques for Multi-Mode Multi-Task Embedded Applications (멀티모드 멀티태스크 임베디드 어플리케이션을 위한 HW/SW 분할 기법)

  • Kim, Young-Jun;Kim, Tae-Whan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.337-347
    • /
    • 2007
  • An embedded system is called a multi-mode embedded system if it performs multiple applications by dynamically reconfiguring the system functionality. Further, the embedded system is called a multi-mode multi-task embedded system if it additionally supports multiple tasks to be executed in a mode. In this Paper, we address a HW/SW partitioning problem, that is, HW/SW partitioning of multi-mode multi-task embedded applications with timing constraints of tasks. The objective of the optimization problem is to find a minimal total system cost of allocation/mapping of processing resources to functional modules in tasks together with a schedule that satisfies the timing constraints. The key success of solving the problem is closely related to the degree of the amount of utilization of the potential parallelism among the executions of modules. However, due to an inherently excessively large search space of the parallelism, and to make the task of schedulabilty analysis easy, the prior HW/SW partitioning methods have not been able to fully exploit the potential parallel execution of modules. To overcome the limitation, we propose a set of comprehensive HW/SW partitioning techniques which solve the three subproblems of the partitioning problem simultaneously: (1) allocation of processing resources, (2) mapping the processing resources to the modules in tasks, and (3) determining an execution schedule of modules. Specifically, based on a precise measurement on the parallel execution and schedulability of modules, we develop a stepwise refinement partitioning technique for single-mode multi-task applications. The proposed techniques is then extended to solve the HW/SW partitioning problem of multi-mode multi-task applications. From experiments with a set of real-life applications, it is shown that the proposed techniques are able to reduce the implementation cost by 19.0% and 17.0% for single- and multi-mode multi-task applications over that by the conventional method, respectively.

Comparative evaluation for leaf position accuracy according to gantry angle variation in MLC quality assurance using electronic portal imaging device(EPID) and GafChromic EBT3 film (전자포탈영상장치(EPID)와 GafChromic EBT3 film을 이용한 다엽콜리메이터 정도관리 시 갠트리 각도 변화에 따른 엽의 위치 정확성 비교 평가)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Lee, Sun Young;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the error of the leaf position accuracy of the MLC due to the gravity effect according to the gantry angle by using picket fence test using EPID and GafChromic EBT3 film. Materials and Methods: A 5 cm solid phantom was placed on the table and the SAD was set to 100 cm. The EBT3 film was placed exactly over the solid phantom and covered a 1.5 cm solid phantom and the picket fence test was performed. The EPID was measured under the same conditions as the EBT3 film at SID 100 cm. The gantry angles were measured at $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ and $270^{\circ}$ in order to evaluate the position of the MLC according to the gantry angle. For the geometric evaluation of the MLC, the leaf position accuracy of the MLC was analyzed using the analysis program. Results: In case of EPID, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.18 mm, 0.31 mm, 0.20 mm, 0.26 mm on the average and the maximum values of the errors were respectively 0.44 mm, 0.54 mm, 0.34 mm, 0.44 mm. In case of EBT3 film, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.19 mm, 0.21 mm, 0.19 mm, 0.31 mm on the average and the maximum values of the errors were respectively 0.35 mm, 0.45 mm, 0.36 mm, 0.48 mm. Conclusion: In this study, we analyzed the position error of the leaf of the MLC according to the gantry angle, and confirmed the position error of the leaf by gravity effect. As a result of comparing the leaf position accuracy using EPID and EBT3 film according to the variation of gantry angle, a larger error occurred in the error analysis method using EPID than that of EBT3 film. Therefore, in the case of IMRT based on MLC, as well as verification of accurate dosimetry should be conducted, it is considered that the quality control and verification for the precise operation of the MLC will be needed. and it is necessary to compare and verify the method of analysis.

  • PDF