• Title/Summary/Keyword: 선량 분포 변화

Search Result 235, Processing Time 0.023 seconds

Evaluate the Change of Body Shape and the Patient Alignment State During Image-Guided Volumetric Modulated Arc Therapy in Head and Neck Cancer Patients (두경부 환자의 VMAT 시 체형변화와 환자 정렬과의 상관관계 고찰)

  • Seo, Se Jeong;Kim, Tae Woo;Choi, Min Ho;Son, Jong Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.109-117
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the change of body shape and the patient alignment state during image-guided volumetric modulated arc therapy in head and neck cancer patients, Materials and Methods: We performed a image-guided volumetric modulated arc therapy plan for 89 patients with head and neck cancer who underwent curative radiotherapy. Ten of them were evaluated for set up error. The landmarks of the ramus, chin, posterior neck, and clavicle were specified using ARIA software (Offline review), and the positional difference was analyzed. Results: The re-CT simulation therapy was performed in 60 men with $17{\pm}4$ cycles of treatment. The weight loss rate was $-6.47{\pm}3.5%$. 29 women performed re-CT simulation at $17{\pm}5$ cycles As a result, weight loss rate was $-5.73{\pm}2.7%$. The distance from skin to C1, C3, and C5 was measured, and both clavicle levels were observed to measure the skin shrinkage changes. The skin shrinkage standard deviations were C1 (${\pm}0.44cm$), C3 (${\pm}0.83cm$), and C5 (${\pm}1.35cm$), which is about 1 mm shrinkage per 0.5 kg reduction. Skin shrinkage according to the number of treatments was 1 ~ 4 fractions (no change), 5 ~ 13 fractions (-2 mm), 14 ~ 22 fractions (-4 mm) and 23 ~ 30 fractions (-6 mm). Conclusion: When the body shape changes about 5 mm, the central dose starts to differ about 3 % or more. Therefore, the CT simulation treatment for the adaptive therapy should be additionally performed. In addition, it is necessary to actively study the CT simulation therapy method and set up method of the lower neck and to examine the use of a new immobilization device.

  • PDF

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

Comparison of Measured and Predicted $^3H$ Concentrations in Environmental Media around the Wolsung Site for the Validation of INDAC Code (주면피폭선량 평가코드(INDAC)의 검증을 위한 월성원전 주면 삼중수소 농도 실측치와 예측치의 비교 평가)

  • Jang, Si-Young;Kim, Chang-Kyu;Rho, Byung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.75-80
    • /
    • 2000
  • The predicted results of INDAC code were compared with measured $^3H$ concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted $^3H$ concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the $^3H$ behavior in vegetables or plants that the ratio of $^3H$ concentration in plant water to $^3H$ concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit calculation performed by the regulator. It was also found that data sets based on mixed mode and no terrain data were not appropriate for the audit calculation ensuring the compliance with regulations. Thus, if the mixed mode is considered as the release mode of effluents into the environment, meteorological data measured at 58 m height and terrain data should be used to evaluate the atmospheric dispersion factor.

  • PDF

Microbiological Characteristics of Gamma Irradiated and Low-Salted Fermented Squid (감마선 조사된 저염 오징어젓갈 발효의 미생물균총 특성)

  • Kim, Dong-Ho;Kim, Jae-Hun;Yook, Hong-Sun;Ahn, Hyun-Joo;Kim, Jung-Ok;Sohn, Cheon-Bae;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1619-1627
    • /
    • 1999
  • Microbiological characteristics of gamma irradiated low salt squid Jeot-gal were examined. Following the fermentation periods, total bacterial cell, Lactobacillus spp., Staphylococcus spp., Streptococcus spp., Pseudomonas spp. and yeast cell number were counted on their selective media and some acid forming bacteria and Pseudomonas spp. were identified. As the gamma irradiation dose increased, the microbial density of early fermentation phase was reduced and the growth rate was delayed. The repression effects on microbiological growth by gamma irradiation were to be higher as salt concentration increased. Adequate conditions of salt concentration and gamma irradiation for low-salt squid Jeot-gal preparation were 10% and 10 kGy, respectively. Lactobacillus sp. 2, Micrococcus varians and Streptococcus sp. I were isolated from 5% salt containing squid Jeot-gal, and Micrococcus morrhuae was from 20% only while Lactobacillus plantarum and Lactobacillus brevis were widespread. Lactobacillus brevis, Pediococcus halophilus and Pseudomonas diminuta were sensitive and Lactobacillus plantarum, Micrococcus morrhuae and Pseudomonas sp. 3 were resistant to gamma irradiation. The diversity of microflora decreased as salt concentration decreased and gamma irradiation dose increased.

  • PDF

The Effect of Hyperthermia Combined with Radiation on Crypts of the Mouse Jejunum (마우스공장 소낭선의 방사선 효과에 온열요법의 병용이 미치는 영향에 관한 실험적 연구)

  • Bae, Hoon-Sik;Park, Charn-Il;Kim, Jung-Jin
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.13-21
    • /
    • 1987
  • The effect of local hyperthermia of 41 to $43^{\circ}C$ for 30 minutes on radiosensitivity of normal tissue was studied utilizing jejunal crypt microcolony assay. Hyperthermia of this range enhanced the radiation effect and the effect was mainly additive without significant effect on the slopes of cell survival curves. At the isoeffect level of 20 microcolony formation, the thermal enhancement ratio was 1.02, 1.10 and 1.39 for $41^{\circ},\;42^{\circ}\;and\;43^{\circ}C$, respectively. The distribution of microcolony formation along the circumference of jejunum was not uniform, having more colonies around the mesenteric border, and this suggests the effect of uneven cooling by blood circulation.

  • PDF

The Study of Normal Tissue Complication Probability(NTCP) for Radiation Pneumonitis by Effective Volume Method (유효체적 방법과 임상분석을 통한 방사선에 의한 정상 폐조직의 부작용 확률에 관한 연구)

  • Ahn Seung Do;Choi Eun Kyung;Yi Byong Yong;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.243-249
    • /
    • 1997
  • Purpose : In radiation therapy, NTCF is very importart indicator of selecting the optimal treatment plan. In our study, we tried to find out usefullness of NTCP in lung cancer by comparng the incidence of radiation pneumonitis with NTCP. Materials and Methods : From August 1993 to December 1994, thirty six patients with locally advanced non=small cell lung cancer were treated by concurrent chemoradiation therapy. Total dose of radiation therapy was 6480cGy (120cGy, bid) and chemotherapeutlc agents were mitomycin C. vinblastion, cisplatin (2 cycles, 4 weeks interval). We evaluated the development of raniation pneumonitis by CT scan, chest x-rar and clinical symptoms. We used grading system of South Western Oncology Group (SWOG) for radiation pneumanitis. Dose Volume Histograms (DVH) were analyzed for ipsilateral and whole lung, Non uniform DVH was translated to uniform DVH by effective volume method. With these data, we calculated NTCP for ipsilateral and whole lung. Finally we compared the clinical results to NTCP. Results : Eight of thrity six patients developed radiation pneumonitis. Of these 8 patients , 6 had grade I severity and 2 had grade II. The average NTCP value cf the patients who showed radiation pneumonitis was significantly higher than that uf the patients without pneumonitis $(66\%\;vs.\;26.4\%)$. But the results of pulmonary function test was not correlated with NTCP. Conclusion : NTCP of lung is very good indicator for selecting rival treatment planning in lung cancer. According to the results of NTCP, it may be possible to adjust target volume and optimize target dose. In the near future, we are going to anaiyze the effect of hyperfractionation and concurrent chemotherapy in addition to NTCP.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

A Definition of Korean Heat Waves and Their Spatio-temporal Patterns (우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.527-544
    • /
    • 2006
  • This study provides a definition of heat waves, which indicate the conditions of strong sultriness in summer, appropriate to Korea and intends to clarify long term(1973-2006) averaged spatial and temporal patterns of annual frequency of heat waves with respect to their intensity. Based on examination of the Korean mortality rate changes due to increase of apparent temperature under hot and humid summer conditions, three consecutive days with at least $32.5^{\circ}C,\;35.5^{\circ}C,\;38.5^{\circ}C,\;and\;41.5^{\circ}C$ of daily maximum Heat Index are defined as the Hot Spell(HS), the Heat Wave(HW), the Strong Heat Wave(SHW), and the Extreme Heat Wave(EHW), respectively. The annual frequency of all categories of heat waves is relatively low in high-elevated regions or on islands adjacent to seas. In contrast, the maximum annual frequency of heat waves during the study period as well as annual average frequency are highest in interior, low-elevated regions along major rivers in South Korea, particularly during the Changma Break period(between late July and mid-August). There is no obvious increasing or decreasing trend in the annual total frequency of all categories of heat waves for the study period However, the maximum annual frequencies of HS days at each weather station were recorded mainly in the 1970s, while most of maximum frequency records of both the HW and the SHW at individual weather stations were observed in the 1990s. It is also revealed that when heat waves occur in South Korea high humidity as well as high temperature contributes to increasing the heat wave intensity by $4.3-9.5^{\circ}C$. These results provide a useful basis to help develop a heat wave warning system appropriate to Korea.

The Measurement of Dose Distribution in the Presence of Air Cavity and Underdosing Effect Result from Lack of Electronic Equilibrium (조사면내 공동의 존재에 따른 선량분포의 변화측정)

  • Jo, Jeong-Hui;Bang, Dong-Wan;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.75-81
    • /
    • 1996
  • When high energy photon beam is incident upon an air cavity interface the effect of ionization build-up observed . This phenomenon is resulting from the surface layers of the lesions are significant deficiency of electrons reaching the layers because of the replacement, of solid scattering material by the air cavity, that is lack of electronic equilibrium. Measurement have been made in an acrylic phantom with a parallel plate chamber and high energy photon beams, CO-60, 4MV, 6MV and 10MV X-rays have been investigated. The result of our study show that a significant effect was measured and was determined to be very dependent on field size, air cavity dimension and photon energy. The reductions were much larger for 10MV beam, underdosage at the interface was 12, 12.2, 16.9 and $20.6\%$ for the CO-60, 4MV, 6MV and 10MV, respectively. It was found that this non-equilibrium effect at the interface is more severe for the higher energy beams than that of lower energy beams and the larger cavity dimensions the larger beam reductions occur. This problem is of clinical concern when lesions such as carcinoma beyond air cavities are irradiated, such as larynx, glottic and the patients with maxillectomy and ethmoidectomy and so forth.

  • PDF

Distribution of Antibiotic Resistant Microbes in Aquaculture Effluent and Disinfection by Electron Beam Irradiation (양식장 배출수중의 항생제 내성균 분포 및 전자빔 살균처리)

  • Jang, Eun-Hee;Lim, Seung-Joo;Kim, Tak-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.492-500
    • /
    • 2011
  • Antibiotic resistant microbes were isolated in catfish, trout, eel and loach aquaculture effluent. The distribution of antibiotic resistant microbes in aquaculture effluent and the disinfection efficiency of antibiotic resistant microbes by electron beam irradiation were investigated. It was shown that the multi-drug resistant bacteria were Aeromonas sp., Citrobacter sp., Bacillus sp., Marinobacter sp., Pantoea sp., Pseudomonas sp. and Enterobacter sp. in aquaculture effluent. 41.7% of total strains showed the resistance against one antibiotic agent, and 58.3% of total strains showed the resistance against more than two antibiotics. It was evidently shown that the toxicity and physicochemical properties of antibiotics can be estimated using Quantitative Structure Analysis Relationship (QSAR). Electron beam irradiation was very effective for the disinfection of antibiotic resistant bacteria from aquaculture effluent, in which the disinfection efficiency was approximately 99.9% with electron beam of 1 kGy.