Radiation Analysis by Chemical Treatment of Agricultural Products in Environmental Samples (환경시료 중 농산물에서 화학적 처리 방법에 의한 방사능 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.531-538
    • /
    • 2017
  • Agricultural products produced in the agricultural area around the nuclear power plant are radioactive contamination, which can cause radioactive contamination to the human body. The purpose of this study was to investigate the limit of the radioactivity concentration $^{90}Sr$ for the internal exposure dose evaluation by ingesting the agricultural products collected around the nuclear power plant. The results of the gamma-isotope element analysis were freshly <0.0166-0.0336 Bq / kg for all samples and for artificial radionuclides not detected, and fresh <0.00586-0.0421 Bq / kg for Chinese cabbage, The freshness was 0.106 Bq / kg, and the freshness was 0.0114-0.0901 Bq / kg. 0.0177%, 0.0222%, 0.0376% and 0.00243%, respectively, for Chinese cabbages and large roots, which is lower than the legal standard value of $1mSv/yr{\cdot}man%$. It is considered that the formulas need to be broadly evaluated for the foods consumed by children and adults, taking into consideration the age of the food and the diet

Determination of Derived Release Limits for a CANDU Nuclear Power Plant (CANDU형 원전에서의 유도방출한도 결정)

  • Kim, Kyo-Youn;Hwang, Hae-Ryong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.23-35
    • /
    • 1994
  • A computer code DRL was developed to calculate the derived release limits at CANDU type nuclear power plants. The derived release limits resulting from DRL code is to set guidelines for the release of radionuclides in airborne and water-borne effuents during normal operations of a CANDU type nuclear power plant. The DRL code generally follows the methodology Prescribed in the CSA standard N288.1-M87 and uses the Parameter values recommended in the same standards. The DRL code was used to calculate a set of preliminary derived release limits for the Wolsong NPP.

  • PDF

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program (진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가)

  • Jeong, Hee-Cheol;Lee, SamYol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.807-812
    • /
    • 2018
  • In this study, we investigated the conditions used in setting the recommendation level of general radiography diagnostic reference and tried to evaluate the effective dose and biological evaluation using PCXMC v2.0 program. As a result based on the effective dose of male in ICRP 60, the highest Pelvis AP was 0.794 mSv. The lowest Chest PA was 0.050 mSv. In the case of ICRP 103, the highest T-Spine AP was 0.906 mSv The lowest Chest PA was 0.052 mSv. For 40 years old male and female adults, effective doses of general radiography were evaluated and even if the medical exposures are not subject to the limit of dose, efforts should be made to reduce the medical exposures of the people by keeping the dose below the recommended amount in order to minimize the probable effect of radiation hazard.

A Measurement of Exposure Dose for Patient Transporter (환자 이송원의 피폭선량 측정)

  • Song, Chaerim;Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.433-438
    • /
    • 2019
  • The medical institutions use radiation generating devices and radioactive isotopes to diagnose and treat patients. The patient transporter performs work in an environment that is more likely to be exposed to radiation when compared with the general public, such as inevitably entering the radiation management area for patient transfer, or transferring the isotope-administered patient at a short distance. For this reason, we conducted a study to determine the degree of exposure of the patient transporter. The 12 patient transporters working at Incheon A General Hospital are eligible. From April 1, 2019 to April 30, 2019, the dosimeter was used in the chest for one month and the accumulated dose was measured. The dosimeter used was a Optically Stimulated Luminescence Dosimetry (OSLD) and the dose reading was OSLD Microstar Reading System. As a result of cumulative dose measurement for one month, the average of the deep dose was 0.13 mSv and the surface dose was 0.13 mSv, and the cumulative dose for one month was multiplied by 12 to estimate the cumulative dose expectation As a result, the average of the deep dose and the surface dose were 1.52 mSv and 1.51 mSv, respectively. It is necessary to classify the patient transporter as a frequent visitor in order to measure and manage the exposure dose, increase the knowledge of protection against radiation through education and training, and prevent radiation trouble through medical examination.

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

Measurement of the Skin Dose of Patient Using the Optically Stimulated Luminescent Dosimeter at Diagnostic Radiography (진단방사선촬영에서 광자극발광선량계를 이용한 환자 피부선량의 측정)

  • Kim, Jong-Eon;Im, In-Chul;Min, Byung-In
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.437-442
    • /
    • 2011
  • The purpose of this study is an measurement of the skin dose of a patient by using the OSLD(optically stimulated luminescent dosimeter) under several irradiation conditions of the X-ray beam for diagnostic radiography. The measurements of skin dose were performed for head, chest, and pelvis. And test of reproducibility was carried out at the chest. As a result, we obtained the skin dose at forehead of head to be 1.30 mSv. The skin doses at xiphoid process, breast and apex of the lung of the chest were acquired 0.92, 0.52 and 0.70 mSv, respectively. And we obtained the skin doses at the left pelvis and the right pelvis to be 2.78 and 3.08 mSv, respectively. As for reproducibility, a coefficient of variation was 0.033. The skin doses were exhibited the values corresponding from 1/100 to 1/17 of the dose limit of the public(50 mSv) at the deterministic effect. In order to make accurate measurements of the skin doses for each tube voltage, the measured values have to multiply by the displayed values of reader by a correction factor. The energy response of the OSLD with the tube voltage will be studied in the near future.

Caregiver or Family Doses due to Discharged $^{131}I$ Administrated Patient from the Hospital (고용량 $^{131}I$ 투여환자 퇴원이후 환자 간병인과 환자 가옥의 피폭선량 측정)

  • Jeong, Gyu-Hwan;Lee, Hyun-Kook;Cho, Woon-Kap;Lee, Jai-Ki
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.149-154
    • /
    • 2010
  • Exposed doses to the patient's caregiver and their house due to the 131I from patients discharged from the hospital were measured using OSL dosimeters. Usually, 3.37-5.55 GBq (100-150 mCi) of $^{131}I$ administrated patients are discharged from the hospital after 3 or 4 days of hospitalization in Korea. In addition, after 5 to 8 days, the accumulated doses of the patient's caregiver and house after hospitalization of the patient were measured using OSL dosimeters. The results of the measured average accumulated doses were 0.1 mSv, which is 10% of 1 mSv, the public dose limit in the Korean Atomic Energy Law. And it's standard deviation was 0.087 mSv. Based on the results of this study, we anticipate that we could assure the compliance of the regulation requirement 5 mSv of MEST (Ministry of Education, Science and Technology) Notice No. 2008-45 for the patient's caregiver or family, even if we reduce the 3-4 days of hospitalization to 1-2 days or less.

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.

Calculation of Route Doses for Korean-based International Airline Routes using CARI-6 and Estimation of Aircrew Exposure (CARI-6를 이용한 국제선 노선별 선량 및 항공승무원의 피폭선량 평가)

  • Hong, J.H.;Kwon, J.W.;Jung, J.H.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • Dose rate characteristics of cosmic radiation field at flight altitudes were analyzed and the route doses to the personnels on board due to cosmic-ray were calculated for Korean-based commercial international airline routes using CARI-6. Annual individual doses to aircrew and the collective effective dose of passengers were estimated by applying the calculated route doses to the flight schedules of aircrew and the air travel statistics of Korea. The result shows that the annual doses to aircrew, around 2.62 mSv, exceed the annual dose limit of public and are comparable to doses of the group of workers occupationally exposed. Therefore it is necessary to consider the frequent flyers as well as the aircrew as the occupational exposure group. The annual collective dose to 11 million Korean passengers in 2001 appeared to be 136 man-Sv. The results should be modified when the dose rates of cosmic radiation at high altitude are revised by taking into account the changes in the radiation weighting factors for protons and neutrons as given in ICRP 92.