• Title/Summary/Keyword: 선량최적화

Search Result 194, Processing Time 0.031 seconds

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

강지진동 분석의 최적화를 위한 고려요소

  • 이석태;조봉곤;이정모;조영삼
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.17-17
    • /
    • 2003
  • 한반도에 있어서의 지진의 영향을 분석하기 위해서는 강지진동 연구가 필수적이다. 강지진동 자료가 부족한 한반도의 특성상 모사를 통해 연구하고 있다. 강지진동 분석을 하기 위해서는 되도록 노이즈가 포함되어 있지 않은 지진파자료를 선택하여 그 지진자료의 스펙트럼 분석을 통해 감쇠상수 k, Q 등을 구한다. 이러한 감쇠상수 값을 통해 한반도의 진동 특성을 이해할 수 있다. 그러나 감쇠상수를 구하는 과정에서 감쇠상수 분석에 사용된 지진자료에 노이즈가 더해졌을 경우, 어떤 형태로 스펙트럼 영역에 영향을 미치고, 감쇠상수에는 어떤 영향을 미치는 지를 연구하여 노이즈효과를 제거할 수 있는 최적화된 분석에 관한 연구가 선행되어야 한다고 본다. 따라서 이번 연구에서는 강지진동 모사프로그램을 가지고 노이즈효과를 적용하면서 감쇠상수에 노이즈가 어떤 영향을 미치는 지에 대한 수치 해석적 연구를 실시하였다. 합성지진파에 이 합성지진파와 전혀 다른 주파수 형태를 보이는 노이즈를 강도를 달리하면서 합성해 본 결과, 노이즈효과를 고려할 수 있는 몇 가지 요소가 있음을 알 수 있었다. 감쇠상수 k값을 강지진동 모사프로그램으로부터 값을 달리하며 합성해 본 결과 노이즈효과를 보이는 것을 알 수 있었으며, 감쇠상수 k를 선형회귀를 통해 $k_{s}$$k_{q}$를 구할 때의 적용 주파수 범위를 변화시켰을 때도 일정한 양상의 노이즈 효과를 보였다. 또 지진자료와 노이즈를 중첩시킨 지진파 시계열 자료의 정부분만을 감쇠상수 k를 구하는 선형회귀에 이용했을 경우에도 노이즈 효과를 보였다. 또한 계산되어 나온 감쇠상수 값으로부터 특정지역의 지반운동의 특성을 이해할 수 있는 스펙트럼 가속도, 최대 가속도, 및 최대속도 값에 따른 감쇠식을 구하였다. 이것을 한반도와 같은 판 내부 환경인 ENA 값과 비교하였으며 기존의 연구와도 비교하였다.심으로부터 지오이드까지의 거리, 지오이드로부터 지표까지의 거리를 정의해주었으며, 각 격자점의 수직구조를 정의하기 위해 깊이에 따른 각 매질의 밀도, P파의 속도, S파의 속도, P파에 대한 Q값, S파에 대한 Q값을 정의 해주었다. S파의 속도를 구하기 위해서 지구 내부 물질을 포아송 매질이라는 가정 하에, 관계식을 $Vp{\;}={\;}SQRT(3){\;}{\times}{\;}Vs$ 이용하였다. 획득한 모델치들을 이용해 동해와 동해 인근 지역에 대한 초기모델을 구축하였다. 약 1 × 10/sup 6/ e/sup -//sec·n㎡ 의 전자선량에 해당되며 이를 기준으로 각각의 illumination angle에 대한 임계전자선량을 평가할 수 있었다. 실질적으로 Cibbsite와 같은 무기수화물의 직접가열실험 시 전자빔 조사에 의해 야기되는 상전이 영향을 배제하고 실험을 수행하려면 illumination angle 0.2mrad (Dose rate : 8000 e/sup -//sec·n㎡)이하로 관찰하고 기록되어야 함을 본 자료로부터 알 수 있었다.운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)운동시키기 위한 육은 71.74±1.66%을 나타내었다. 각각의 운동조건에서 양식된 참돔은 사육초기에는 큰 변화가 없었으나, 사육 5일 이후에는 수분함량이 증가하여 15일에는 76.40±0.14, 75.62±0.98%의 수분함량을 2회와 1회 운동시킨 참돔의 육에서 각각 나타났다. 운동횟수에 따른 지

  • PDF

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

Implicit Distinction of the Race Underlying the Perception of Faces by Event-Related fMRI (Event-related 기능적 MRI 영상을 통한 얼굴인식과정에서 수반되는 무의식적인 인종구별)

  • Kim Jeong-Seok;Kim Bum-Soo;Jeun Sin-Soo;Jung So-Lyung;Choe Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • A few studies have shown that the function of fusiform face area is selectively involved in the perception of faces including a race difference. We investigated the neural substrates of the face-selective region called fusiform face area in the ventral occipital-temporal cortex and same-race memory superiority in the fusiform face area by the event-related fMRI. In our fMRI study, subjects (Oriental-Korean) performed the implicit distinction of the race while they consciously made familiar-judgments, regardless of whether they considered a face as Oriental-Korean or European-American. For race distinction as an implicit task, the fusiform face areas (FFA) and the right parahippocampal gyrus had a greater response to the presentation of Oriental-Korean faces than for the European-American faces, but in the conscious race distinction between Oriental-Korean and European-American faces, there was no significant difference observed in the FFA. These results suggest that different activation in the fusiform regions and right parahippocampal gyrus resulting from superiority of same-race memory could have implicitly taken place by the physiological processes of face recognition.

  • PDF

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

Awareness and Consciousness Survey of Worker's for Radiation Exposure Dose Reduction from Pediatric Brain CT Examination (소아두부 컴퓨터단층촬영검사에서 방사선피폭선량 저감화를 위한 근무자의 인식도와 의식도 조사)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • In this study, it was an investigation of the degree of awareness and consciousness of the radiology technicians about radiation protection working in the computed tomography room in Busan when the pediatric underwent brain CT scan. It was sorted by university hospital, general hospital and hospital and compared the scores of awareness and consciousness. As a result of awareness, university hospital had the highest point of 42.29 followed by general hospital and hospital of 38.43 and 34.06 respectively. On the other hand, the average score of consciousness was the highest in hospital of 29.19 followed by general hospital and university hospital of 24.68 and 21.37 respectively. It is considered to need assistance to cultivate an awareness of the radiation through refresher training and conferences, etc in order to increase the awareness of the general hospitals and hospitals for CT workers. In addition, it is also expected to pay for efforts to increase the consciousness of CT workers in university hospitals seeking the optimization of radiation protection and dose reduction of radiation exposure for the pediatric.

The Optimization of NDT Method for Real Time X-ray Imaging (X선 실시간 영상장치를 이용한 비파괴시험 조건 최적화 연구)

  • Na, Sung-Youb;Choi, Yong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • This study has investigated the optimization of NDT method and the minimum detectable defect size for complex structures such as the solid propellant rocket motor using real time X-ray imaging system. Test specimens were made of steel plates with various defect size, and installed with proper thickness for which solid propellant, rubber, and case converted to the steel equivalent thickness according to the radiographic equivalent theory. As the results, this examination obtained optimum magnification and X-ray energy, dose rate according to steel equivalent thickness, also, obtained the relationship between minimum detectable defect size and the ratio(defect depot/object thickness). Thus, this simulated test is the preliminary procedure before performing NDT for real objects, and is possibly applied for NDT of other complex structures.

  • PDF

Derivation of Intervention levels for Protection of the Public in a Radiological Emergency in Korea (주민보호조치를 위한 국내 방사선비상 개입준위 산출)

  • Lee, Jong-Tai;Lee, Goan-Yup;Khang, Byung-Oui;Oh, Ki-Hoon;Kim, Chang-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.357-365
    • /
    • 2001
  • Intervention levels for protection of the public in a radiological emergency are theoretically derived by the cost-benefit approach with the concept of justification and optimization. Intervention levels on the sheltering, evacuation, temporary relocation and permanent resettlement for protection of the public are estimated with the cost to protective countermeasures and the value from dose averted which are the site specific parameters. As a result, it is confirmed that IAEA guidelines for intervention levels are applicable to the radiological emergency in Korea. Optimum ranges of 5 - 10 mSv/2days for sheltering, 25 - 130 mSv/week for evacuation, 15 - 90 mSv/month lot temporary relocation and 600 - 3,500 mSv/lifetime for permanent resettlement for intervention levels are also provided. The result can be applied as useful data to update intervention levels under the theoretical background in Korea.

  • PDF

Application for Limitation of Food Stuffs in a Radiological Emergency (방사선비상시 식품섭취제한 기준 및 적용성)

  • Lee, Jong-Tai;Lee, Goan-Yup;Khang, Byung-Oui;Oh, Ki-Hoon;Kim, Chang-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.89-94
    • /
    • 2002
  • Intervention levels for foodstuff restriction in a radiological emergency in Korea are suggested based on the justification and the optimization through the cost-benefit approach method from IAEA Safty Series 109 recommendation. Intervention levels are specified for three broad groups of radionuclides with similar values of committed effective dose per unit intake and specified for two broad categories of foodstuff grouped according to value per kg. It is also discussed on the applicability of revised intervention levels for foodstuff restriction.