• Title/Summary/Keyword: 선량율

Search Result 773, Processing Time 0.029 seconds

The Results of Hvperfractionated Radiation Therapy Combined with Taxol for Paraaortic Node Recurrence in Cervix Cancer (대동맥주위 림프절에 재발된 자궁경부암에서 Taxol을 병행한 과분할 방사선치료의 결과)

  • Kim, Jun-Sang;Jang, Ji-Young;Kim, Jae-Sung;Kim, Sam-Yong;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • Purpose : The aim of this study was to investigate treatment results, toxicity and efficacy of hypefractionated radiation therapy combined with paclitaxel for paraaortic node recurrence in cervix cancer. Materials and Methods: Between September 1997 to March 1999, 12 patients with paraaortic node recurrence in cervix cancer who previously received radical or postoperative radiotherapy were treated with hypefractionated radiation therapy combined with paclitaxel. Of these, 2 patients who irradiated less than 30 Gy were excluded, 10 patients were eligible for this study. Median age was 51 years. Initial FIGO stage was 1 stage IBI, 2 stage IIA, 7 stage IIB. For initial treatment, 7 patients received radical radiotherapy and 3 received postoperative radiotherapy. The paraaortic field encompassed the gross recurrent disease with superior margin at T12, and inferior margin was between L5 and S1 with gap for previously pelvic radiation field. The radiation field was initially anterior and posterior opposed field followed by both lateral field. The daily dose was 1.2 Gy, twice daily fractions, and total radiotherapy dose was between 50.4 and 60 Gy(median, 58.8 Gy). Concurrent chemotherapy was done with paclitaxel as a radiosensitizer. Dose range was from 20 mg/m$^{3}$ to 30 mg/m$^{3}$ (median, 25 mg/m$^{3}$), and cycle of chemotherapy was from 3 to 6 (median, 4.5 cycle). Follow-up period ranged from 3 to 21 months. Results : Interval between initial diagnosis and paraaortic node recurrence was range from 2 to 63 months (median, 8 months). The 1 year overall survival rate and median survival were 75$\%$ and 9.5 months, respectively. The 1 year disease free survival rate and median disease free survival were 30$\%$ and 7 months, respectively. At 1 month after treatment, 4 (40$\%$) achieved a complete response and 6 (60$\%$) experienced a partial response and all patients showed response above the partial response. There was distant metastasis in 6 patients and pelvic node recurrence In 2 patients after paraaortic node irradiation. There was 2 patients with grade 3 to 4 leukopenla and 8 patients with grade 1 to 2 nausea/ vomiting which was usually tolerable with antlemetic drug. There was no chronic complication in abdomen and pelvis during follow up period. Conclusion : hypefractionated radiation therapy combined with paclitaxel chemotherapy diosensitizer showed high response rate and few complication rate in paraaortic node recurrence in cervix cancer Therefore, present results suggest that hypefractionated radiation therapy combined with paclitaxel chemotherapy can be used as optimal treatment modality in this patients.

  • PDF

Radiotherapy in Incompletely Resected Gastric Cancers (불완전 절제된 위암의 방사선 치료)

  • Kim Jong Hoon;Choi Eun Kyung;Cho Jung Gil;Kim Byung Sik;Oh Sung Tae;Kim Dong Kwan;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.17-25
    • /
    • 1998
  • Purpose : Although local recurrence rates of stomach cancer after radiocal surgery have been reported in the range of $30-70\%$, the role of postoperative adjuvant therapy has not been established. We report the result of radiotherapy in resected stomach cancer with positive surgical margin to elucidate the role of postoperative radiotherapy. Materials and Methods : From June 1991 to August 1996, twenty five patients with positive surgical margins after radical gastrectomy were treated with postoperative radiotherapy and chemotherapy. Median dose of radiation was 55.8Gy and the range was 44.6-59.4Gy. Second cycle of chemotherapy was delivered concurrently with radiation and total number of six cycles were delivered. Twenty three had adenocarcinoma and the other two had leiornyosarcoma. The numbers of patients with stage I B, II, III A, III B, and IV were 1, 2, 11, 10 and 1 respectively. Positive margins at distal end of the stomach were in 17 patients and proximal in 5. The other three patients had positive margin at the sites of adjacent organ invasion Minimum and median follow-up periods were 12 months and 18 months, respectively, Results : Twenty-four of 25 patients received prescribed radiation dose and RTOG grade 3 toxicity of UGI tract was observed in 3, all of which were weight loss more than $15\%$ of their pretreatment weight. But hematemesis. melena, intestinal obstruction or grade 4 toxicity were not found. Locoregional failure within the radiation field was observed in 7 patients, and distant metastasis in 10 patients. Sites of locoregional recurrences involve anastomosis/remnant stomach in 3, tumor bed/duodenal stump in 3, regional lymph node in 1 patient Peritoneal seeding occurred in 6, liver metastases months and median disease free survival time was 26 months. Stages andradiation dose were not significant prognostic factors for locoregional in 2, and distant nodes in 2 patients. Four year disease specificsurvival rate was $40\%$ and disease free survival was $48\%$. Median survival was 35 failures. Conculsion : Although all patients in this study had positive surgical margins, locoregional failure rate was $28\%$, and 4 year disease specific survival rate was $40\%$. Considering small number of patients and relatively short follow-up period, it is not certain that postoperative radiotherapy lowered locoregional recurrences. but we could find a Possibility of the role of postoperative radiotherapy in Patients with high risk factors.

  • PDF

Fabrication of Combined Probes for Interstitial hyperthermia and Brachyradiotherapy (고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성)

  • Chu, Sung-Sil;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.85-87
    • /
    • 2004
  • We fabricated flexible thermoradiotherapy probes to alternated combination with Interstitial hyperthermia and Brachyradiotherapy thermoradiotherapy probe was coated by gold plate on polyethylene brachytherapy probe. When Agar phantom was heated 15 minute with 30 W radiofrequency power, temperature increased as 5oC for polyethylene probe and 20oC for gold coated polyethylene probe. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures (90% relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature (90% relative SAR using Tm). The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50 min to generate tissue temperatures of 43${\circ}$C. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from 7${\sim}$30 days. The acute stage was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (days30)canine brain.

  • PDF

Microbiological and Physiological Qualities of Electron-beam and Gamma-ray Irradiated Sprout Seeds(Radish, Red cabbage) during Germination (전자빔과 감마선 조사된 무순 및 적양배추 종자의 발아 중 미생물학적 및 생리적 품질특성)

  • Park, Ju-Hwan;Kim, Gui-Ran;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.186-191
    • /
    • 2009
  • An electron beam or gamma-rays(0-5 kGy) were applied to two popular commercial sprout seeds, those of radish and red cabbage, and both physiological and microbiological qualities during germination were examined. Total bacterial counts of radish and red cabbage seeds were 5.02 and 2.86 log CFU/g, respectively, and were reduced by 2-3 logs after irradiation, but nonirradiated and irradiated samples showed similar microbial populations on day 5 after germination, although day 3 levels of irradiated samples were $23{\pm}2%$ lower. Coliforms were absent in both seed types. However, they were detected from the first day of germination, and rose to 4-5 log CFU/g on the fifth day. Coliforms were reduced by about 1-2 log CFU/g in 1 kGy-irradiated samples and were absent in the samples irradiated at 3 kGy. Irradiation at 1 and 3 kGy decreased germination by about 7% and 18%, respectively. Sprout yield and length were also significantly affected by irradiation, with no apparent difference between samples treated with the electron beam and gamma-rays.

Measurement of neutron spectra in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector (LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용한 MC50 사이클로트론의 중성자스펙트럼 측정)

  • Ha, Wi-Ho;Park, Seyoung;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jungho;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.143-148
    • /
    • 2013
  • Operational nuclear facilities such as nuclear power plants and particle accelerators show various neutron spectra according to the type of facilities and specific position. Necessities of neutron dose management and neutron monitoring for radiation protection of radiation workers in such a kind of facilities have continuously increased in recent years. Bonner sphere spectrometers are widely used for measurement of neutron spectra. Data on response function of neutron detector, default neutron spectra and count rates of Bonner sphere spectrometer are required to obtain unfolded neutron spectra in specific workplaces. In this study, we carried out measurement of neutron spectra produced in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector. Additionally, we estimated quantitative data on neutron flux, mean neutron energy and ambient dose equivalent rate according to the incident proton energies and positions in MC50 cyclotron.

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

Effect of Radiation Therapy on Atelectasis from Lung Cancer (무기폐를 동반한 폐암의 방사선 치료)

  • Hong, Seong-Eon;Hong, Young-Ki
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.73-77
    • /
    • 1990
  • From January 1981 to December 1989, total 42 patients with atelectasis from lung cancer were treated with radiation therapy at the Department of Therapeutic Radiology in Kyung Hee University Hospital. The reexpansion of atelectasis after radiotherapy of the lung was evaluated retrospectively, utillzing treatment records and follow-up chest radiographs. Of the patients with non-small cell carcinoma of the lung, the response rate was $62\%$ (21/34). Patient with small cell carcinoma showed a $75\%$ (6/8) response rate. There appears to be some evidence of a relationship of total tumor dose versus response of atelectasis; radiation dose over 40 Gy (1337 ret), had a favorable effect on the rate of response compared with that below 40 Gy (1297 ret), $70\%$(21/30) and $50\%$ (6/12), respectively (p<0.01). Total response rate (partial and complete responses) of all patients was $64\%$ (27/42). Franction size was not contributed to the difference of response rates between small fraction ($180\~200$ cGy) and large fraction (300 cGy), $53\%$ (14/22) and $65\%$ (13/20), respectively. The results of this study suggest that radiation therapy has a definite positive role in management of atelectasis caused by lung cancer, especially in inoperable non-small cell carcinoma.

  • PDF

Monte Carlo Calculation of the Dose Profiles for a 6 MeV Electron Beam with Longitudinal Magnetic Fields (세로 자기장에서 6 MeV 전자선의 선량분포에 관한 몬데칼로 계산)

  • 오영기;정동혁;신교철;김기환;김정기;김진기;김부길;이정옥;문성록
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.195-201
    • /
    • 2002
  • Several investigators have presented the effects of external magnetic fields on the dose distributions for clinical electron and photon beams. We focus the low energy electron beam with more lateral scatter In this study we calculated the beam profiles for an clinical electron beam of 6 MeV with longitudinal magnetic fields of 0.5 T-3.0 T using a Monte Carlo code. The principle of dose enhancements in the penumbra region is to deflect the laterally scattered electrons from its initial direction by the skewness of the laterally scattered electrons along the direction of magnetic field lines due to Lorentz force under longitudinal magnetic field. To discuss the dose enhancement effect on the penumbra area from the calculated results, we introduced the simple term of penumbra reduction ratio (PRR), which is defined as the percentage difference between the penumbra with and without magnetic field at the same depth. We found that the average PRR are 33%, and 49% over the depths of 1.5 cm, 2.0 cm, and 2.4 cm for the magnetic fields of 2.0 T and 3.0 T respectively. For the case of 0.5 T and 1.0 T the effects of magnetic filed were not observed significantly. In order to obtain the dose enhancement effects by the external magnetic field, we think that its strength should be more than 2 T approximately. We expect that the PRR would be saturated to 50-60% with magnetic fields of 3 T-5 T As a result of these calculations we found that the penumbra widths can be reduced with increased magnetic fields. This Penumbra reduction is explained as a result of electron lateral spread outside the geometrical edges of the beam in a longitudinal magnetic field. This means that the electron therapy benefits from the external magnetic fields.

  • PDF

Thermal Behavior and Abrasion Properties of Glass Fiber Reinforced Nylon 12 Crosslinked by Electron Beam Irradiation (전자선 가교된 유리섬유 강화 나일론 12의 열적 거동 및 내마모 특성)

  • Shin, Bum-Sik;Jeun, Joon-Pyo;Kim, Hyun-Bin;Kang, Phil-Hyun
    • Polymer(Korea)
    • /
    • v.35 no.1
    • /
    • pp.30-34
    • /
    • 2011
  • In this study, the effects of the electron beam irradiation on the thermal behavior and the abrasion properties of the glass fiber reinforced nylon 12 was investigated. The electron beam irradiation was carried out over a range of irradiation dose from 100 to 600 kGy with additive crosslinking agents such as triallyl cyanurate (TAC), triallyl isocyanurate (TAIC) and trimethylolpropane trimethacrylate (TMPTMA) for enhancing the crosslinking effects. The gel contents were increased dramatically above 200 kGy. It was verified that the degree of crosslinking depends on the radiation dose. The decreases of the melting temperature and the area of endothermic peak were observed as increasing the absorbed dose in the results of DSC analysis. The enhanced thermal stability was confirmed by the increases of decomposition temperature by electron beam irradiation. Furthermore, the negative deviations of the abrasion loss and the abrasion coefficients confirmed the improvement of the abrasion properties of irradiated nylon 12, as evidenced by SEM observation on the abrasion surfaces. The addition of the crosslinking agents to nylon 12 during effectively improved the thermal behavior and the abrasion properties of nylon 12 by the electron beam irradiation.