• Title/Summary/Keyword: 선량변화

Search Result 1,215, Processing Time 0.026 seconds

Effects of hydrocolloids on wheat flour rheology (Hydrocolloid의 첨가가 밀가루 반죽의 특성에 미치는 영향)

  • 임경숙;황인경
    • Korean journal of food and cookery science
    • /
    • v.15 no.3
    • /
    • pp.203-209
    • /
    • 1999
  • The effect of several hydrocolloids on the rheological behavior of wheat flour was investigated. The influence of the selected hydrocolloids (alginate, carrageenan, CMC, guar, locustbean and xanthan) on wheat flour was tested by using two different techniques; amylograph and texture analyzer. In order to have a general overview of their effects hydrocolloids were chosen from different sources implying a broad diversity of chemical structures. The hydrocolloid addition decreased the brightness(L) but increased yellowness(b). The interaction between hydrocolloid and flour produces a slight modification of the amylogram parameters, being the most clearly affected parameter breakdown, which is increased by carrageenan, guar and xanthan. Hardness and cutting force were augmented by hydrocolloid addition, while springeness was decreased except guar and locustbean. In summary, when looking for the improvement of the noodle texture, guar, locustbean are the best candidate additives due to their effects on pasting and texture properties. These hydrocolloids increase the hardness, cutting force, gumness, chew-ness, so were thought to increase the eating quality. So, each tested hydrocolloid affected in a different way the rheological properties of wheat flour, the results obtained are important for the appropriate use of these hydrocolloid as ingredients in the noodle making process.

  • PDF

Comparative Analysis of Growth and Antioxidant Enzyme Activities from Two Chrysanthemum Varieties, 'ARTI-purple' and 'ARTI-queen' by Chronic Irradiation of Gamma-ray (감마선 완조사에 따른 국화 'ARTI-purple'과 'ARTI-queen'의 생육 및 항산화 효소 활성 비교 분석)

  • Sung, Sang Yeop;Lee, Yu-Mi;Kim, Sang Hoon;Ha, Bo-Geun;Kang, Si-Yong;Kim, Jin-Baek;Kim, Dong Sub
    • Horticultural Science & Technology
    • /
    • v.31 no.4
    • /
    • pp.490-495
    • /
    • 2013
  • Two chrysanthemum varieties, 'ARTI-purple' and 'ARTI-queen', were chronically irradiated with doses of 30, 50, 70, and 100 Gy for four weeks in gamma-phytotron, a long term irradiation facility. We investigated the growth, responses of antioxidant enzymes (ascorbate peroxidase, APX; catalase, CAT; peroxidase, POD; superoxidase dismutase, SOD) and malondialdehyde (MDA) contents under different doses of chronic-irradiation. The five plant growth measurements including plant height, number of leaves, internode length, stalk diameter and leaf thickness were investigated immediately after four week irradiation. The plant height (p<0.001), internode length (p<0.01), the number of leaves (p<0.001) and stalk diameter (p<0.05) were significantly decreased an increasing doses of gamma-ray. Among them, especially, the internode length was remarkably decreased showing the RD50 (Reduction Dose 50) at approximately 65 Gy. The antioxidant response after four weeks of recovery period, ascorbate peroxidase (APX) (p<0.01), superoxide dismutase (SOD) (p<0.01) and peroxidase (POD) (p<0.001) were significantly increased with an increasing dose of gamma-ray. And malondialdehyde (MDA) (p<0.01) contents showed the significant increase at the 70 and 100 Gy which means the oxidative stress was lasting for a considerable period. In this study, the 50 Gy irradiation as optimal dose showed higher growth than the $RD_{50}$, it also showed insignificant differences on the antioxidant responses and MDA contents. However, the 100 Gy dose showed lower growth than $RD_{50}$.

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Alteration of Phospholipase D Activity in the Rat Tissues by Irradiation (방사선 조사에 의한 쥐 조직의 포스포리파제 D의 활성 변화)

  • Choi Myung Sun;Cho Yang Ja;Choi Myung-Un
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.197-206
    • /
    • 1997
  • Purpose : Phospholipase D (PLD) catalyzes the hydrolysis of phosphatidylcholine to phosphatidic acid (PA) and choline. Recently, PLD has been drawing much attentions and considered to be associated with cancer Process since it is involved in cellular signal transduction. In this experiment, oleate-PLD activities were measured in various tissues of the living rats after whole body irradiation. Materials and Methods : The reaction mixture for the PLD assay contained $0.1\;\muCi\;1,2-di[1-^{14}C]palmitoyl$ phosphatidylcholine 0.5mM phosphatidylcholine, 5mM sodium oleate, $0.2\%$ taurodeoxycholate, 50mM HEPES buffer(pH 6.5), 10mM $CaCl_2$, and 25mM KF. phosphatidic acid, the reaction product, was separated by TLC and its radioactivity was measured with a scintillation counter. The whole body irradiation was given to the female Wistar rats via Cobalt 60 Teletherapy with field size of 10cmx loom and an exposure of 2.7Gy per minute to the total doses of 10Gy and 25Gy. Results : Among the tissues examined, PLD activity in lung was the highest one and was followed by kidney, skeletal muscle, brain, spleen, bone marrow, thymus, and liver. Upon irradiation, alteration of PLD activity was observed in thymus, spleen, lung, and bone marrow. Especially PLD activities of the spleen and thymus revealed the highest sensitivity toward $\gamma-rar$ with more than two times amplification in their activities In contrast, the PLD activity of bone marrow appears to be reduced to nearly $30\%$. Irradiation effect was hardly detected in liver which showed the lowest PLD activity. Conclusion : The PLD activities affected most sensitively by the whole-body irradiation seem to be associated with organs involved in immunity and hematopoiesis. This observation s1ron91y indicates that the PLD is closely related to the physiological function of these organs, Furthermore, radiation stress could offer an important means to explore the phenomena covering from cell Proliferation to cell death on these organs.

  • PDF

Microbiological Contamination of Ice Cream Commercially Available in Korea and its Irradiation Effect (시판 아이스크림의 미생물 오염도 및 감마선 조사효과)

  • Kim, Hyun-Joo;Jo, Cheor-Un;Kim, Dong-Soo;Yook, Hong-Sun;Byun, Myung-Woo
    • Journal of Animal Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.867-876
    • /
    • 2005
  • The microbial contamination of ice cream product commercially available in Korea was determined using ice bar, ice cream, ice milk and non-milk fat ice cream. Irradiation effect on enhancement of microbiological safety was also investigated at doses of 1, 3, and 5 kGy. In all products, yeast and molds were not detected, however, total aerobic and coliform bacteria were detected at 1-2 and 1-1.5 Log CFU/g level, respectively. According to the different flavor used in ice cream, total aerobic bacteria were detected as 2.30, 2.90, and 3.32 Log CFU/g level in vanilla, chocolate, and strawberry ice cream, respectively. Yeast and mold was not detected in vanilla ice cream but 2.30 and 2.70 Log CFU/g in chocolate and strawberry ice cream, respectively. Coliforms were also detected 1-2 Log CFU/g in the ice cream with different flavors. Listeria inocua and Escherichia coli were detected from 3 commercial samples but Salmonella spp. was not detected using API kit. Gamma irradiation significantly reduced the level of the contaminated total aerobic bacteria, yeast and molds and coliform population in the ice creams. These results indicated that irradiation(5kGy or less) is effective to ensure safety of ice cream.

Expression of Growth Factors and Secretory Leukocyte Protease Inhibitor (SLPI) in RAW264.7 Cells after Lipopolysaccharide (LPS) Stimulation (대식세포주 (RAW264.7)에서 박테리아성 지질다당류 (LPS) 자극에 의한 분비백혈구단백분해효소억제제 (SLPI)와 성장인자들의 발현)

  • Son, Wook-Hee;Choi, Baik-Dong;Jeong, Soon-Jeong;Wang, Guan-Lin;Hwang, Ho-Keel;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Secretory leukocyte protease inhibitor (SLPI) was known as one of bacterial lipopolysaccharide (LPS)-induced products of macrophage. Macrophages play an important role in the development of inflammatory responses by secreting an array of cytokines and chemokines in a tissue microenvironment. To identify the function and relationship between potent growth factors and SLPI after LPS stimulation, we conducted reverse transcriptase polymerase chain reaction (RT-PCR) and Western blots for the detection of mRNA and protein expression of SLPI and growth factors such as VEGF, PDGF, bFGF after 100 ng LPS stimulation on the RAW264.7 cells. The result of RT-PCR was showed SLPI mRNA expression was increased from 60 min to 48h in RAW 264.7 cells after incubation with LPS. VEGF and PDGF mRNA was expressed highly at initial stage by LPS stimulation. The mRNA of bFGF and type I collagen was very weakly expressed after LPS stimulation. SLPI protein level was increased likely the mRNA levels in RAW 267.7 cells. Additionally, phase contrast and scanning electron microscopic observation demonstrated that the LPS induce the change of morphology of the RAW264.7 cells. From these results, it suggest that expression of SLPI by LPS treatment may associate with VEGF and PDGF expression in RAW264.7 cells.

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Radiation Therapy for Pituitary Adenoma -Changes in Endocrine Function after Treatment- (뇌하수체선종의 방사선치료후 혈중 호르몬치의 변화)

  • Yoon Sei Chul;Jang Hong Suck;Kim Song Hwan;Shinn Kyung Sub;Bahk Yong Whee;Son Ho Young;Kang Joon Ki
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.185-195
    • /
    • 1991
  • Seventy four patients with pituitary adenoma received radiation therapy (RT) on the pituitary area using 6 MV linear accelerator during the past 7 years at the Division of Radiation Therapy, Kangnam St. Mary's Hospital, Catholic University Medical College. Thirty nine were men and 35 were women. The age ranged from 7 to 65 years with the mean being 37 years. Sixty five ($88\%$) patients were treated postoperatively and 9 ($12\%$) primary RT, To evaluate the effects of RT, we analyzed the series of endocrinologic studies with prolactin (PRL), growth hormone (GH), adrenocorticotrophic hormone (ACTH), leuteinizing hormone (LH), follicular stimulating hormone (FSH) and thyroid stimulating hormone (TSH) etc after RT. All but one with Nelson's syndrome showed abnormal neuroradiologic changes in the sella turcica with invasive tumor mass around supra- and/or parasella area. The patients were classified as 23 ($29\%$) prolactinomas and 20 ($26\%$) growth hormone (GH) secreting tumors, and 6 ($8\%$ ACTH secreting ones consisting of 4 Cushing's disease and 2 Nelson's syndrome. Twentynine ($37\%$) had nonfunctioning tumor and four ($5\%$) of those secreting pituitary tumors were mixed PRL-GH secreting tumors. The hormonal level in 15 ($65\%$) of 23 PRL and 3 ($15\%$) of 20 GH secreting tumors returned to normal by 2 to 3 years after RT, but five PRL and five GH secreting tumors showed high hormonal level requiring bromocriptine medication. Endocrinologic insufficiency developed by 3 years after RT in 5 of 7 panhypopituitarisms, 4 of seven hypothyroidisms and one of two hypogonadisms, respectively. Fifteen ($20\%$) patients were lost to follow up after RT.

  • PDF

Significance of Apoptotic Cell Death after $\gamma-Irradiation$ (방사선 조사에 의한 세포사에 있어서 세포고사의 의미)

  • Wu H.G.;Kim I.H.
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.252-258
    • /
    • 2001
  • Purpose : The objectives of this study are to investigate the significance of apoptotic death compared to total cell death after $\gamma-ray$ irradiation in human H&N cancer cell lines and to find out correlation between apoptosis and radiation sensitivity. Materials and method : Head and neck cancer cell lines (PCI-1, PCI-13, and SNU-1066), leukemia cell line (CCRF-CEM), and fibroblast cell line (LM217) as a normal control were used for this study. Cells were irradiated using Cs-137 animal experiment irradiator. Total cell death was measured by clonogenic assay. Annexin-V staining was used to detect the fraction of apoptotic death. Results : Surviving fraction at 2 Gy (SF2) were 0.741, 0.544, 0.313, 0.302, and 0.100 for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217 cell lines, respectively. Apoptosis was detected in all cell lines. Apoptotic index reached peak value at 72 hours after irradiation in head and neck cancer cell lines, and that was at 24 hours in CCRF-CEM and LM217. Total cell death increased exponentially with increasing radiation dose from 0 Gy to 8 Gy, but the change was minimal in apoptotic index. Apoptotic fractions at 2 Gy were $46\%,\;48\%,\;46\%,\;24\%,\;and\;19\%$ and at 6 Gy were $20\%,\;33\%,\;35\%,\;17\%,\;and\;20\%$ for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217, respectively. The radioresistant cell lines showed more higher apoptotic fraction at 2 Gy, but there was not such correlation at 6 Gy. Conclusion : All cell lines used in this study showed apoptosis after irradiation, but time course of apoptosis was different from that of leukemia cell line and normal fibroblast cell line. Reproductive cell death was more important mode of cell death than apoptotic death in all cell lines used in this study. But there was correlation between apoptotic fraction and radiation sensitivity at 2 Gy.

  • PDF