• Title/Summary/Keyword: 선량(船梁)

Search Result 4,656, Processing Time 0.039 seconds

Effects of γ-Irradiation from Cobalt-60 on pathogenicity of Eimeria tenella (Cobalt-60 감마선 조사가 Eimeria tenella 의 병원성에 미치는 영향)

  • Youn, Hee-jeong;Kang, Young-bai;Jang, Du-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.649-655
    • /
    • 1993
  • A series of experiments on the effects of ${\gamma}-irradiation$ was performed to reveal the pathogenicity of ${\gamma}-irradiated$ oocysts of E tenella from Cobalt-60 and its progeny. The SPF chickens were inoculated with differnt doses of radiation and inoculum. The level of 100 Gy ${\gamma}-irradiation$ from $^{60}Co$ and the level of inoculum with $1{\times}10^4$ oocysts were recognized more pathogenic than those of the other groups by comparison of body weight gains, blood in feces and lesion scores. The signs of blood in feces, lesion score and the number of excreted oocysts in the feces were revealed as the lowest in the group of the ${\gamma}-irradiated$ oocysts, the average in the group of the 1st and the 3rd progeny, and the highest in the group of non-irradiated oocysts of E $tenell\grave{a}$. The body weight gain of the group immunized with ${\gamma}-irradiated$ oocysts of E tenella was higher than those of the non-irradiated, the 1st and 3rd progeny groups. The body weight gain of the groups immunized with the 1st and the 3rd progeny of E tenella were higher than that of the non-irradiated group. The feed conversion ration of the group immunized with ${\gamma}-irradiated$ oocysts of E tenella was lower than those of the non-irradiated, the 1st and the 3rd progeny groups. The feed conversion ratios of the group immunized with the 1st and 3rd progeny of ${\gamma}-irradiated$ oocysts were lower than that of the group infected with non-irradiated E tenella. The anticoccidial index(ACI 190.6) in the chickens immunized with the ${\gamma}-irradiated$ oocysts of E tenella and those(ACI 142.8 and 107.4) of the 1st and the 3rd progeny groups were higher than that (ACT 87.4) of the group infected with non-irradiated E tenella. It was thought that the pathogenicity of ${\gamma}-irradiated$ E tenella would be recovered according to increase the number of generation passaged in chicken.

  • PDF

The Effect of Ginkgo Biloba Extract on Hypoxic Fraction of C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 저산소세포 분획에 미치는 영향)

  • Cho Chul Koo;Yi Chun Ja;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.205-214
    • /
    • 1995
  • Purpose : To investigate the effect of Ginkgo biloba extract (GBE) on hypoxic cell fraction and metabolic status in fibrosarcoma (FSa II) of C3H mouse. Materials and Methods : Fibrosarcoma (FSa II) 6 mm in diameter, growing in the right hindleg muscle of C3H mouse was used for estimation of hypoxic cell fraction using comparison of $TCD_{50}$. Radiation was given one hour after administration of GBE (100 mg/kg. i.p.) with or without priming dose of GBE (100 mg/kg, i.p.) given 24 hours earlier. Radiation was also given under air breathing condition or clamp hypoxia without GBE as controls. $^{31}p$ NMR spectroscopy was performed before and one hour after administration of GBE with or without priming dose of GBE. Results : $TCD_{50/120's}$ were 81.7 (77.7-86.0) Gy when irradiated under clamped hypoxia 69.6 (66.8-72.5) Gy under air breathing condition. 67.5 (64.1-71.1) Gy with a single dose of GBE (100 mg/kg) given one hour before irradiation, and 62.2 (59.1-65.5) Gy with two doses of GBE given at 25 hours and one hour before irradiation. The hypoxic cell fractions, estimated from $TCD_{50/120's}$, were $10.6{\%}$ under air breathing condition, $7.2{\%}$ after a single dose of GBE, and $2.7{\%}$ after two doses of GBE. The results of $^{31}P$ NMR spectroscopy were as follow. PCr/Pi ratio was $0.27{\pm}0.04$ and $0.40{\pm}0.04$ before and one hour after a single dose of GBE (p<0.05), respectively, without priming dose and $0.30{\pm}0.02$ and $0.71{\pm}0.04$, respectively, with priming dose (p<0.01). These findings indicate that the metabolic status is slightly improved after a single dose and markedly after repeated administrations. Conclusion : GBE decreases the hypoxic cell fraction and imprvoes the meta bolic status of tumor, probably by increasing the blood flow and delivery of oxygen and nutrients, resulting in increased radiosensitivity of tumor.

  • PDF

Long-term Follow-up after Radiation Therapy Alone for Esophageal Carcinoma (식도암의 방사선치료 성적 - 장기 추적관찰의 결과)

  • Wu Hong-Gyun;Park Suk-Won;Park Charn-Il
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.441-446
    • /
    • 1998
  • Purpose : The incidence of esophageal carcinoma is increasing. Radical surgery is the treatment of choice, but large proportion of the esophageal cancer patients are with unresectable disease at the time of initial diagnosis, so radiation therapy has been the major treatment modality. We carried out retrospective analysis to see the outcome and prognostic factors of radiation therapy alone for esophageal carcinoma. Methods and Materials : From June of 1979 through December 1992, 289 patients with esophageal carcinoma were treated with radiation therapy alone at Department of Therapeutic Radiology, Seoul National University Hospital. Of these patients, 84 patients were excluded as they were ineligible for the current analyses. Twenty-two patients had distant metastasis other than supraclavicular lymph node metastasis, 52 patients received less than 45 Gy, and 10 patient were lost from follow-up. Therefore 205 patients constituted the base population of this study. According to AJCC s1aging system, there were 2 patients with stage 1, 104 with stage IIA, 26 with stage IIB, 48 with stage III, and 25 with stage IV Radiation dose ranged from 4500 cGy to 6980 cGy with median dose of 5940 cGy. Follow-up period of the alive patients ranged from 77 to 180 months. Results : The Median survival period of all the patients was II months and the 2-, 5-, and 10-year overall survival rates were 22.4$\%$, 10.2$\%$ and 5.3$\%$, respectively. Most of the failures were local recurrences. Of 169 failures, 134 had local failure as a component and 111 had local recurrence only. The Lymph node was most common distant metastatic site and the next was the lung. The stage, T-stage, N-stage, functional status, tumor size, and aim of treatment were statistically significant prognostic factors for survival by univariate analyses. But only tumor size and N-stage were significant by multivariate analyses. Conclusion : We could get 10.2$\%$ of 5 year survival rate and 5.3$\%$ of 10 year survival rate with radiation therapy alone. The size of tumor and N-stage were statistically significant prognostic factors for survival on multivariate analyses.

  • PDF

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.

Surgical Outcome of Patients with Ischemic Cardiomyopathy Selected by the Results of Myocardial Viability by Preoperative F-18 FDG PET (F-18 FDG 양전자단층촬영을 이용한 생존심근 평가 후 수술한 허혈성 심근병증 환자의 수술 결과)

  • Kim, Jae-Sung;Lee, Dong-Soo;Hong, Suk-Keun;Lee, Young-Tak;Kim, Yu-Kyeong;Kim, Youn-Jung;Moon, Keon-Sik;Won, Tae-Kyoung;Hwang, Hweung-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • Purpose: We investigated the operative outcome after bypass surgery in patients selected using viability criteria on F-18 FDG PET. Materials and Methods: Rest-24hr delay redistribution imaging of Tl-201 SPECT and F-18 FDG PET were performed in 11 patients. Seven of these 11 patients (6 men, 1 woman) were evaluated to have viable myocardium by F-18 FDG PET. Changes in symptoms and left ventricular ejection fraction (LVEF) after operation were evaluated. Results: In seven of 11 patients, a significant amount of viable myocardium was found on F-18 FDG PET and Tl-201 SPECT. Severity of both chest pain and dyspnea improved markedly in all patients. Mean LVEF improved from 22% to 32%. Conclusion: F-18 FDG PET could be used to select the patients who will benefit from coronary artery bypass surgery.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF