• Title/Summary/Keyword: 석탄기

Search Result 378, Processing Time 0.024 seconds

3D Resistivity Survey at a Collapsed Tunnel Site (붕락 터널에서의 3차원 전기비저항 탐사)

  • Cho, In-Ky;Kim, Ki-Seog;Lee, Keun-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.1
    • /
    • pp.14-20
    • /
    • 2015
  • Three-dimensional (3D) resistivity method is an effective tool in the engineering site survey because it can provide a 3D resistivity distribution of the site. In this study, we tried to find out faults, fractures and coal seams that can cause the collapse of the tunnel. We carried out 2D resistivity survey along 5 parallel lines and 11 cross lines and merged all the apparent resistivity data for 3D inversion. Finally, from the 3D resistivity image and drilling data we presented the 3D distribution of faults, fractures and coal seams that are considered the main cause of the tunnel collapse.

Characterization of Unburned Carbon Particles from Fly Ash Using SEM (비산회로부터 회수한 미연탄소분의 전자현미경을 이용한 특성분석)

  • Ahn, Yang-Kyu;Kil, Dae-Sup
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.567-573
    • /
    • 2002
  • The most important and largest commercial outlet of fly ash in Korea is a replacement material of Portland cement in concrete industry. The high level of unburned carbon in ash brings about some malfunctions in concrete. Therefore, fly ash is refined to improve the quality as a concrete additive. In this process, a lot of the residual carbon is produced, and discarded now. In the present study, to find out a valuable outlet of the enriched carbon samples, the basic morphology of residual carbon in fly ash from Boryung power plant was investigated. The unburned carbon characterization included shape, size measurement, and chemical analysis was examined using scanning electron microscope (SEM) and energy dispersive X-ray spectrometer (EDX).

Finite Element Analysis for the Behavior of the Casing of a Pulverizer Mill Planetary Gear Reducer (석탄 분쇄기용 유성감속기 케이싱의 거동에 관한 유한요소해석)

  • Seo, Ji-Hwan;Kim, Seon-Jin;Jung, Min-Hwa;Kim, Byung-Tak
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.34-39
    • /
    • 2014
  • In this study, the structural analysis and the modal analysis are conducted to investigate the stress level, the deformation characteristics and the natural modes of the casing of a planetary gear reducer for a 800kW grade pulverizer mill. The casing is subjected to the load, 2800 kN, from the lump coals in the pulverizing process. Because of the symmetry, the half portion of the reducer casing is modeled for the stress analysis. But the full model is used to find out the eigenvalues and natural modes for the modal analysis. The contact conditions are applied between the thrust pad bearing and the adjacent contacting parts. The results shows that the casing structure has the sufficient strength and stiffness to support the load under consideration. ANSYS version 15 is employed to perform the numerical study.

Economic Analysis of Dry Bottom Ash Handling System in a Pulverized Coal Thermal Power Plant in Korea (國內 微分炭 火力發電所에서 바닥재 再活用을 위한 乾式 바닥재 處理시스템 導入의 經濟性 分析)

  • Oh, Se-Won
    • Resources Recycling
    • /
    • v.13 no.5
    • /
    • pp.51-56
    • /
    • 2004
  • Economic benefits of the dry bottom ash handling system over the wet bottom ash handling system in a new 500MW${\times}$2units pulverized coal thermal power plant in Korea were evaluated. The higher initial capital cost in the dry bottom ash handling system was estimated. However, this higher initial capital costs would be compensated with reductions of the operating cost mainly due to the recycling of bottom ash. Economic analysis showed that the payback period of 4.9 years and the internal rate of return at 21.1% were expected for the additional initial capital cost of the dry bottom ash handling system.

A Study of Regeneration Reaction for Desulfurization Sorbents using Natural Manganese Ore (천연 망간 광석 탈황제의 재생 반응 특성 연구)

  • 윤여일;윤용승;김성현
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.247-253
    • /
    • 2002
  • Natural manganese ore was selected as main active component for a non-zinc desulfurization sorbent used in the gas clean-up process of the integrated gasification combined cycle (IGCC) because of excellent H$_2$S removal efficiency and economical aspect . In this study, the regeneration characteristics of sorbent after desulfurization reaction were determined in a thermobalance reactor and a fixed bed reactor in the temperature range of 350~55$0^{\circ}C$. The mixed gases of oxygen and nitrogen are used as the regeneration reaction gases for manganese sorbent. According to Mn-S-O phase diagram, the manganese sorbent has a low regeneration efficiency in medium temperature due to formation of MnSO$_4$ and the regeneration temperature must be over 85$0^{\circ}C$. To improve that problem, ammonia and steam was added in regeneration mixed gases. Effect of new regeneration method was determined by XRD and difference of desulfurization through multicycle tests.

Performance Analysis of IGCC Gas Turbine Considering Turbine Operation Condition Change due to Modulation of Nitrogen Dilution (질소희석량 조절에 따른 터빈 운전조건 변화를 고려한 IGCC 용 가스터빈의 성능분석)

  • Kim, Chang Min;Kang, Do Won;Kim, Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1023-1029
    • /
    • 2013
  • The integration between a gas turbine and an air separation unit (ASU) is important in IGCC plants. The portion of ASU air extracted from the gas turbine and the degree of nitrogen supply from the ASU to the gas turbine side are important operating parameters. Their effect on the gas turbine performance and operability should be considered in a wide ambient temperature range. In this study, appropriate nitrogen dilution rate and turbine inlet temperature that satisfy the two limitations of turbine blade temperature and maximum allowable power output were predicted. The air integration was set at zero. The simulation showed that the power output increases and turbine blade temperature decreases as the nitrogen dilution increases. The maximum allowable power output can be obtained under medium and low ambient temperature ranges. Under a high ambient temperature range, the achievable power is less than the maximum power.

Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant (발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측)

  • Jin, Kyung-Yong;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • This study presents prediction of maximum fly ash conveying capacity of fly ash system in a power plant. The mixture ratio and pressure drop characteristics of air-fly ash flow in piping system are not well understood due to the complexity of particle motion mechanism. In this paper, the researcher investigated the optimum mixture ratio when the pressure drop of fly ash conveying system is equal to maximum static pressure of displacement fly ash transport blower and the capacity of fly ash transport according to the optimum mixture ratio by experimenting the fly ash conveying system of domestic D coal thermal power plants, which is currently in operation. The experiment results showed that the maximum fly ash conveying capacity of fly ash system were founded under the condition of maximum air volume 5,040 m3/h, static pressure of trip condition 1,163 mmH2O. In addition, it was predicted maximum mixture ratio of the air-fly ash was 8.66 and maximum capacity of fly ash conveying was 52,600 kg/h under these conditions.

  • PDF

Areal Distribution Ratios of the Constituent Rocks with the Geologic Ages and Rock Types in the Chungbug-Chungnam-Daejeon Areas (충북-충남-대전지역 구성암류의 지질시대별 및 암종별 분포율)

  • Yun, Hyun-Soo;Lee, Jin-Young;Yang, Dong-Yoon;Hong, Sei-Sun
    • The Journal of the Petrological Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.191-205
    • /
    • 2008
  • In order to use the geologic information data such as industrialization of rock resources, site enlargement and development planning, distributive ratios of rock types and geologic ages were obtained by the ArcGIS 9.2 program, and digital geologic and geographic maps of 1:250,000 scale, in the Chungbug, Chungnam and Daejeon areas, respectively. In the Chungbug area, 64 rock kinds are developed and their geologic ages can be classified into 8 large groups. In the geologic ages, the ratios are decreasing in the order of Jurassic, Precambrian, Age-unknown, Cretaceous, Quaternary, Cambro-Ordovician and Carboniferous-Triassic ages, all of which comprise most ratios of 98.48% in the area. In the rock types, the ratios show the decreasing order of Jurassic Daebo granite, Precambrian banded gneiss of Gyeonggi metamorphic complex, Cretaceous biotite granite, Quaternary alluvium, Great limestone group, Lower phyllite zone and Meta-sandy rock zone of age-unknown Ogcheon group, Triassic Cheongsan granite, Precambrian granitic gneiss of Gyeonggi gneiss complex, Pebble bearing phyllite zone of age-unknown Ogcheon group and biotite gneiss of Sobaegsan metamorphic complex, all of which comprise the prevailing ratio of 84.27% in the area. In the Chungnam area, 35 rock types are developed and their geologic ages can be classified into 6 large groups. In the geologic ages, the ratios are decreasing in the order of Precambrian, Jurassic and Quaternary ages, which occupy the prevailing ratio of 87.55% in the area. In the rock types, the ratios show the decreasing order of Jurassic Daebo granite, Precambrian banded gneiss of Gyeonggi metamorphic complex, Quaternary alluvium, Precambrian granite and granitic gneiss of Gyeonggi gneiss complex, Cretaceous acidic dykes, Lower phyllite zone and Pebble bearing phyllite zone of age-unknown Ogcheon group and Quaternary reclaimed land, which occupy the ratios of 74.28% in the area. In the Daejeon area, 11 rock types are developed and their geologic ages can be classified into 5 large groups. In the ages, the ratios are decreasing in the order of Jurassic, Age-unknown and Quaternary, which occupy most ratios of 93.40% in the area. In the rock types, the ratios show the decreasing order of Jurassic Daebo granite, Quaternary alluvium and Lower phyllite zone and Pebble bearing phyllite zone of age-unknown Ogcheon group, which occupy the prevailing ratios of 91.09% in the area.

백동지역 변성염기성암과 그 주변암에서의 고생대 후기 변성작용과 그에 대한 지구조적 의미 해석

  • 오창환;전은영;최선규;송석환
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2001.06a
    • /
    • pp.143-144
    • /
    • 2001
  • 경기육괴의 남서부에 해당하며 옥천구조대의 북쪽에 위치한 백동-홍성 일대의 충청남도 일원에는 선캠브리아기의 편마암복합체내에 초염기성암체들이 소규모 렌즈상의 암체로 이 지역에 우세한 구조선 방향인 북북동 방향으로 배열되어 산출된다. 이들 초염기성암채들이 조산대에 형성되는 알파인형이며 전형적인 상부 맨틀기원의 암석이 부분용융된 맨틀 잔여물로서 지표로의 이동과정에서 변성작용을 받아 대부분은 사문석화 혹은 활석화된 것으로 보고되어 있다. 본 연구의 주대상인 변성염기성암을 포함하는 백동지역의 초염기성암은 홍성도폭내 덕정리 편암암체 내에 주변 편마암체와 단층으로 접하면서 나타난다. 덕정리 편마암체는 주로 각섬석 화강편마암으로 구성되어있다. 백동지역의 초염기성암내에는 변성염기성암이 층상으로 협재되어 나타난다. 이들 변성염기성암은 석류석, 단사휘석, 각섬석, 사장석으로 주로 이루어진 석류석 각섬암이며 금홍석도 포함하고 있다. 많은 석류석 주변에는 사장석과 각섬석으로 이루어진 심플렉타이트가 발달되어있다. 석류석 각섬암내 심플렉타이트가 형성되지 않은 석류석 가장자리로부터 계산된 변성 온도-압력 조건은 590-72$0^{\circ}C$, 9-l0kb이며 심플렉타이트가 잘 형성된 석류석 주변부로부터는 490-$600^{\circ}C$, 4-6.3kb의 변성 온도-압력 조건이 계산되었다. 이에 반해 변성염기성암을 포함한 초염기성암체 주변에 나타나는 석류석-각섬석 화강편마암으로 부터는 570-78$0^{\circ}C$, 11.6-l6kb의 변성 온도-압력 조건을 얻었다. 석류석 각섬암에서 석류석내에 포획물로 나타나는 휘석(Xjd, 4-11)이 기질에 나타나는 휘석(Xid, 1-6)보다 높은 제이다이트 성분을 갖는다. 이는 석류석 중심부가 석류석 주변부보다 변성압력 조건이 높았을 가능성을 지시한다. 즉 연구지역의 석류석 각섬암은 주변의 각섬석 화강편마암과 같이 에콜로자이트상-상부각섬암상-고압백립암상의 점이대에 해당하는 변성작용을 받은후 초염기성암의 사문암화 작용시기에 1차 후퇴변성작용을 그리고 그후의 활석화 시기에 심플렉타이트를 형성하는 2차 후퇴변성작용을 받았다. 이러한 후퇴변성작용시기에 많은 유체가 침입하였고 그 결과 초염기성암내의 변성염기성암이 주변 화강편마암보다 후퇴변성작용을 강하게 받았을 것으로 예상된다. 변성염기성암의 변성연대를 구하기 위해 두 석류석 각석암 시료에 대해 석류석-전암 Sm-Nd 등시선 연령을 구하였다. 두 개의 석류석 각섬암으로부터 계산된 전암-석류석 연령은 297.9$\pm$5.7(2$\sigma$)Ma 그리고 268.7$\pm$3.3(2$\sigma$)Ma를 나타낸다. 석류석의 Sm-Nd 폐쇄온도가 700-75$0^{\circ}C$임을 고려할 때 두 석류석 각섬암으로부터 계산된 연대는 최고 변성작용 혹은 초기 냉각 시기를 지시할 가능성이 높다. 한편 전암의 두 동위원소 자료로부터 계산된 전암의 연령은 408Ma이다. 이러한 연구 결과는 연구지역의 석류석 각섬암이 시루리아기 후기 혹은 데본기 초기에 관입 후 석탄기 후기에서 페름기 중기에 주변 화강편마암과 함께 섭입작용을 받았을 가능성을 지시한다.

  • PDF

A study on the engineering optimization for the commercial scale coal gasification plant (상용급 석탄가스화플랜트 최적설계에 관한 연구)

  • Kim, Byeong-Hyeon;Min, Jong-Sun;Kim, Jae-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.131.1-131.1
    • /
    • 2010
  • This study was conducted for engineering optimization for the gasification process which is the key factor for success of Taean IGCC gasification plant which has been driven forward under the government support in order to expand to supply new and renewable energy and diminish the burden of the responsibility for the reduction of the green house gas emission. The gasification process consists of coal milling and drying, pressurization and feeding, gasification, quenching and HP syngas cooling, slag removal system, dry flyash removal system, wet scrubbing system, and primary water treatment system. The configuration optimization is essential for the high efficiency and the cost saving. For this purpose, it was designed to have syngas cooler to recover the sensible heat as much as possible from the hot syngas produced from the gasifier which is the dry-feeding and entrained bed slagging type and also applied with the oxygen combustion and the first stage cylindrical upward gas flow. The pressure condition inside of the gasifier is around 40~45Mpg and the temperature condition is up to $1500{\sim}1700^{\circ}C$. It was designed for about 70% out of fly ash to be drained out throughout the quenching water in the bottom part of the gasifier as a type of molten slag flowing down on the membrane wall and finally become a byproduct over the slag removal system. The flyash removal system to capture solid particulates is applied with HPHT ceramic candle filter to stand up against the high pressure and temperature. When it comes to the residual tiny particles after the flyash removal system, wet scurbbing system is applied to finally clean up the solids. The washed-up syngas through the wet scrubber will keep around $130{\sim}135^{\circ}C$, 40~42Mpg and 250 ppmv of hydrochloric acid(HCl) and hydrofluoric acid(HF) at maximum and it is turned over to the gas treatment system for removing toxic gases out of the syngas to comply with the conditions requested from the gas turbine. The result of this study will be utilized to the detailed engineering, procurement and manufacturing of equipments, and construction for the Taean IGCC plant and furthermore it is the baseline technology applicable for the poly-generation such as coal gasification(SNG) and liquefaction(CTL) to reinforce national energy security and create new business models.

  • PDF