• Title/Summary/Keyword: 서베이미터

Search Result 11, Processing Time 0.026 seconds

Report of Present Status of Calibration for Domestic Radiation Measurements Instruments (국내 방사선 측정장비 보유 현황 및 교정 현황 조사)

  • Lim, Sangwook;Choi, Jinho;An, Sohyun;Cho, Kwang Hwan;Lee, Sang Hoon;Lee, Rena;Cho, Sam Ju
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2016
  • Periodical calibrations of radiation detectors are important for accurate quality assurance of therapeutic linac. The measuring instruments such as ion-chamber, thermometer, barometer, and survey meter should be calibrated periodically. Period of calibration for these instruments is suggested 6 month to one year in Korea and two years in other countries nowadays. Therefore, the determination of reasonable period for calibration is needed. In this study, we plan to utilize the results of these survey; frequent in use, how to use and stability of instruments, to determine the optimized period of calibration for the instruments in the departments of radiation oncology in Korea based on the ILAC-G24. The SurveyMonkey web-based survey tool was used and the objects of survey were 18 department of radiation oncology in university hospitals, and 15 departments were answered. The 64 questionnaires which supposed to be answered in 50 minutes were classified as the information of candidates, the thermometer, the barometer, the surveymeter, and the ion-chamber. The thermometers and the barometers were not under periodical calibration for more than half of candidates. The periods of calibration of surveymeters were 6 month to 1 year. We expect that the calibration period can be determined based on these survey results.

Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument (방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Lee, Yun-Hee;Kim, Ho-Dong;Jung, Ki-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.246-254
    • /
    • 2006
  • A computation program has been developed for automatic data processing in the calibration process of gamma survey meter. The automatic processing program has been developed based on Visual Basic. The program has been coded according to steps of calibration procedure. The OLE(object linking an embedding) Excel automation method fur automatic data processing is used in this program, which is a kind of programming technique for the Excel control. The performance test on the basis of reference data has been carried out by using the developed program. In the results of performance test, the values of calibration factors and uncertainties by the developed program were equal to those obtained from the reference data. In addition, It was revealed that the efficiency and precision of working are significantly increased by using the developed program.

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Evaluation for Performance of a Military Radiation Detecter PDR-1K : Focused on Dependence of Angular and Energy (군사용 방사선 계측기 PDR-1K 반응도 평가 : 방향 및 에너지 의존성을 중심으로)

  • Park, Wonseok;Choi, Junhyuk;Jung, Doyoung;Kim, Jango;Min, Byungin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.300-305
    • /
    • 2017
  • In this paper, we performed a evaluation for angular and energy dependence of military radiation detector PDR-1K. Its measuring range is divided into two section, low and high, and each range has a GM tube separately owing to broad scale. We observed a change in relative angular reactivity within 0.928 ~ 1.188 in low range and within 0.743 ~ 1.000 in high range from $-90^{\circ}$ to $+90^{\circ}$. The evaluation for energy dependence appeared a relative reactivity within 0.892 ~ 1.000 above 83 keV. This means PDR-1K isn't possible to use below 83 keV of radiation energy. It is possible to provide response information to user and to increase reliability of radiation measurement through this paper.

Development of shielding device for bremsstrahlung radiation from Y-90 microspheres (Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구)

  • Park, Jun Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2019
  • Purpose Yttrium-90 (Y-90) is high-energy beta emitters ($E{\beta}$, max = 2.28 MeV) with the mean penetration depth of 2.5 mm in tissue. Radioactive microspheres containing Y-90 is widely used for the transarterial radioembolization of hepatocellular carcinoma. However, bremsstrahlung radiation from Y-90 can cause the external radiation exposure to medical staff who handle the Y-90 microspheres. In this study, shielding device for Y-90 microspheres was developed to minimize the external radiation exposure. Materials and Methods Y-90 microsphere shielding device was made from 6 mm thicknesses of tungsten including the lead glass window. Radiation shielding ability of Y-90 microsphere shielding device was evaluated using 4 GBq of $SIR-Spheres^{(R)}$ Y-90 microspheres. The bremsstrahlung radiation was measured using radiation survey meter. Results The mean radiation dose of Y-90 microspheres in acrylic shield was $261.7{\pm}2.3{\mu}Sv/h$ (n=5) at 10 cm away from the shield. With the additional tungsten shielding device, it was $23.7{\pm}1.3{\mu}Sv/h$ (n=5). Thus, the bremsstrahlung radiation dose was decreased by 90.9%. At 50 cm away from the shield, bremsstrahlung radiation was reduced by 89.2% after using tungsten shielding device. Conclusion During the preparation and radioembolization of Y-90 microsphere, medical staff are exposed to external radiation. In this study, we demonstrated that the use of tungsten shielding device devices significantly reduced the amount of bremsstrahlung radiation. Y-90 microsphere tungsten shielding device can be highly effective in reducing the bremsstrahlung radiation.