수평편판에서의 착상인자를 고려한 서리 물성치의 상관식 (Correlations of Frost Properties Considering the Environmental Parameters over a Cold Flat Plate)

  • 이관수;김용철;지성
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1046-1052
    • /
    • 2001
  • This study has been performed experimentally to measure the frost properties over a cold flat plate in order to obtain the correlations of the frost properties with various environmental parameters. Correlations of the frost surface temperature, thickness, density, and thermal conductivity are presented along with the experimental results as a function of environmental parameters, distance from the leading edge of test plate, and time. These correlations can be used to predict the frost properties with a maximum error of 8% in the following ranges : air temperature 15∼25$\^{C}$, relative humidity 60∼80%, air velocity 1∼3m/s and cooling plate temperature -15∼-25$\^{C}$.

휜의 열전도를 고려한 평판 휜에서의 착상 거동 (Behaviors of Frost Formation on a Plate Fin Considering Fin Heat Conduction)

  • 김정수
    • 대한설비공학회지:설비저널
    • /
    • 제38권12호
    • /
    • pp.51-60
    • /
    • 2009
  • 본 연구에서는 착상 조건 하에서 열교환기 휜의 열전도를 고려하여 휜 표면에서의 착상 거동을 예측하기 위하여 수학적 모델을 제시한다. 이 때, 공기측은 착상 현상에 대한 3차원 유동 변화의 영향을 고려한다. 서리층 두께에 대한 해석 결과는 실험 결과를 최대 10% 오차 내에서 잘 예측한다. 유동에 수직한 방향(z-dir.)의 서리층 두께 성장은 휜의 열전도에 의해 휜 바탕 근처에서 활발하고, 휜 끝으로 갈수록 지수함수적으로 둔화된다. 휜의 열전도를 고려한 경우에 비해 휜의 표면온도가 일정한 조건에서 서리층 두께는 최대 2배, 열전달량은 평군 10% 정도 과대 예측한다. 따라서, 열교환기 휜에서의 착상 거동을 정확하게 예측하기 위해 착상 모델 해석 시 휜의 열전도를 고려해야 한다. 휜의 열전도 고려 유무에 따른 착상 거동의 차이를 보완하기 위해 열전달량에 대한 등가온도를 산출하며, 이를 근거로 무차원 등가 온도 상관식을 도출한다.

  • PDF

냉각평판에 형성된 서리층의 물성치 (Properties of the Frost Layer Formed on a Cold Flat Surface)

  • 김성곤;양동근;이관수
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.374-380
    • /
    • 2003
  • This paper proposes dimensionless correlations predicting properties of the frost layer formed on a cold flat surface. Experiments are carried out to obtain the correlations with various environmental parameters such as air temperature, air velocity, absolute humidity, and cooling plate temperature. As a result, the frost properties (frost layer thickness, density, surface temperature, thermal conductivity) are correlated as a function of Reynolds number, Fourier number, absolute humidity and non-dimensional temperature by using a dimensional analysis. The correlations agree well with the previous and our experimental data within a maximum error of 10%, and are used to predict the frost properties in the following ranges: Reynolds number of 20216 to 53763, Fourier number of 0.1962 to 2.5128, absolute humidity of 3.22 to 8.47, and non-dimensional temperature of 0.125 to 0.5.

저온 평판에서의 서리층 성장 예측 (Prediction of Frost Layer Growth on a Cold Plate)

  • 지성;이관수;여문수
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1325-1331
    • /
    • 2002
  • This study presents a numerical model to predict the behavior of frost layer growth. The characteristics of the heat and mass transfer inside the frost layer are analyzed by coupling the air flow with the frost layer. The present model is validated by comparing with the several other analytical models. It has been known that most of the previous models cause considerable errors depending on the working conditions or correlations used in predicting the frost thickness growth, whereas the model in this work estimates the thickness of the frost layer more accurately within an error of 10% in comparison with the experimental data. Simulation results are presented for variations of heat and mass transfer during the frost formation and for the behavior of frost layer growth along the direction of air flow.

서리층 성장 예측을 위한 수치적 모델 (The numerical model for predicting frost layer growth)

  • 이관수;지성;이태희
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.249-258
    • /
    • 1997
  • In this study, a numerical model for analyzing frost formation phenomena on a cold flat plate has been developed. Both regions of air flow and frost layer have been coupled to calculate the amount of the heat and mass transfer between air flow and frost layer. Experiments have been also conducted to validate the numerical model. The present numerical results show a good agreement with the experimental data. The present numerical model also provides some useful data such as the temperature distribution inside the frost layer which could not be obtained through the experiments.

  • PDF

열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식 (Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin)

  • 김경민;김정수;김장현;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구 (An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System)

  • 박상균;오철
    • 한국항해항만학회지
    • /
    • 제30권1호
    • /
    • pp.113-117
    • /
    • 2006
  • 이 실험의 목적은 튜브형 증발관에서 입구 공기 속도, 온도와 상대 습도에 따른 서리층 생성의 비교 검토에 있다. 입구 공기 속도와 온도는 각각 $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,\;15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$로 하였고, 상대 습도는 $70\%\~90\%$로 하였다. 그리고 일반적인 공조기용 열교환기에서의 서리발생 현상을 파악하기 위하여 냉각튜브의 온도를 $-15^{\circ}C$로 일정하게 유지하였다. 그 결과 공급공기의 상대습도, 유속 및 온도가 증가할수록 서리 생성량이 증가함을 알 수 있었다.

열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향 (Effects of fin pitch and array of the frost laver growth on extended surface of a heat exchanger)

  • 양동근;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1461-1466
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The characteristics of the frost formation on staggered fin array are somewhat different from those of in-line array. The frost layer at the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 mm, the frost layer growth of second fin in the staggered array is affected by that of first fin. The frost layer growth and heat transfer of single fin deteriorate with decreasing fin pitch regardless of fin array, however, the thermal performance of a heat exchanger, considering increase of heat surface area, becomes better.

  • PDF

열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향 (Effects of Fin Pitch and Array on the Frost Layer Growth on the Extended Surface of a Heat Exchanger)

  • 양동근;이관수
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.711-717
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The frost behaviors of the staggered fin array are somewhat different from those of in-line array. The frost layer formed on the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 m, the frost layer growth of second fin in the staggered array is affected by that of first fin. The thickness of the frost layer and heat transfer of single fin are reduced with decreasing fin pitch regardless of fin array. However, the thermal performance of a heat exchanger is enhanced due to the increase of heat transfer surface area.

찬공기 호수지형에서 서리발생시 하층대기 특성 - 경상남도 하동을 중심으로 (Characteristics of the Lower Boundary Layer during Frost Nights)

  • 황규홍;이정택;허승오;심교문
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2001년도 춘계 학술발표논문집
    • /
    • pp.65-67
    • /
    • 2001
  • 경계층(boundary layer)은 대류권(troposhpere)의 일부분으로써 지구 표면에 직접적인 영향을 주고, 두께는 지표에서 100∼3000m이다. 고기압의 영향을 받는 지역에서 수직 경계층은 일출후부터 일몰 전까지인 낮 시간에 난류 혼합층(turbulent mixed layer), 낮 시간에 형성된 혼합층이 야간에 잔류하는 층, 야간 안정 경계층(Stable Boundary Layer:SBL)으로 나눌 수 있다(Stull, 1988).(중략)

  • PDF