• Title/Summary/Keyword: 생활 폐기물

Search Result 398, Processing Time 0.031 seconds

Field Application of Biocovers in Landfills for Methane Mitigation (매립지 메탄 저감을 위한 바이오커버의 현장 적용 평가)

  • Jung, Hyekyeng;Yun, Jeonghee;Oh, Kyung Cheol;Jeon, Jun-Min;Ryu, Hee-Wook;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.45 no.4
    • /
    • pp.322-329
    • /
    • 2017
  • Two pilot-scale biocovers (PBCs) were installed in a landfill, and the methane ($CH_4$) concentrations at their inlets and outlets were monitored for 240 days to evaluate the methane removability. Consequently, the packing materials were sampled from the PBCs, and their potential $CH_4$ oxidizing abilities were evaluated in serum vials. The $CH_4$ concentration at the inlet of the biocovers was observed to be in the range of 23.7-47.9% (average = 41.3%, median = 42.6%). In PBC1, where a mixture of soil, earthworm cast, and compost (7:2:1, v/v) was employed as the packing material, the $CH_4$ removal efficiency was evaluated to be between 60.7-85.5%. In PBC2, which was filled with a mixture of soil, earthworm cast, perlite, and compost (4:2:3:1, v/v), the removal efficiency was evaluated to be between 29.2-78.5%. Although the packing materials had an excellent $CH_4$ oxidizing potential (average oxidation rate for $CH_4=180-199{\mu}g\;CH_4{\cdot}g\;packing\;material^{-1}{\cdot}h^{-1}$), $CH_4$ removal efficiency in PBC1 and PBC2 decreased to the range of 0-30% once the packing materials in the PBCs were clogged and channeled. Furthermore, seasonal effects exhibited no significant differences in the $CH_4$ removal efficiency of the biocovers. The results of this study can be used to design and operate real-scale biocovers in landfills to mitigate $CH_4$ buildup.

광미/광폐석 처리를 위한 고형화 공정 실증 실험

  • Jeon Ji-Hye;Choi Ae-Jeong;Kim In-Su;Lee Min-Hui;Jang Yun-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.166-170
    • /
    • 2006
  • 본 연구에서는 폐광산 주변에 산재되어 있는 광미/광폐석을 처리하기 위하여 고형화 실증 실험을 수행하였다. 고형화 공정에서 흔히 사용하는 포틀랜드 시멘트와 MSG-E, MSG-N을 고화제로 사용하였으며 현장 광미 및 광폐석을 대상으로 고화체를 양생하고 고화체의 압축강도 및 중금속 용출 정도를 측정하였다. 고화체의 물리/화학적 특성을 비교하기 위해 광미/고화제 비율, 배합수/고화제 비율 그리고 고화체 양생기간을 실험인자로 설정하였다. 실험 결과 광미/고화제의 비율 1:1 만을 고려하더라도 중금속 용출의 급격한 감소가 이루어지는 것을 확인할 수 있었으며 광미/고화제의 비율을 3:1 이하로 유지시키는 경우, 고화체의 압축강도가 현행 폐기물 관리법(20조 관련)에서 규정하고 있는 차단형 매립시설 내부막의 압축강도 기준인 $0.21kgf/mm^2$ 보다 높은 것으로 나타났다. 다양한 pH를 갖는 수용액에 대하여 시간에 따른 고화체의 중금속 용출률을 측정한 결과, 수용액의 pH가 1과 13인 강산/강염기 용액에서 일부 중금속의 용출 농도가 지하수 생활용수 기준치를 초과하였으나, pH와 3 - 11인 경우에는 중금속 용출률이 급격히 감소하여 모두 기준치 이하를 나타내었다. 또한, pH가 1과 13인 수용액의 경우에도 고화체와 반응하는 시간이 증가할수록 고화체의 buffering 효과에 의해 수용액의 pH가 감소하였다. 이러한 결과는 현장에서 접촉수의 pH가 강산이나 강염기라 하여도, 고화체의 buffering 효과에 의해 시간이 지남에 따라 수용액의 pH가 낮아져 고화체로부터의 중금속 용출은 매우 감소할 것임을 의미한다.ss of an active application defined using the model. The technique is developed in a platform- and language-independent way, and it is algorithmic and can be automated by computer program. We give an example dealing with network auction to illustrate the use of the model and the verification technique.품으로 내부 온도분포를 측정하였으며, 유한차분법 프로그램으로 대류열전달계수를 결정하였다. 대류열전달계수는 792에서 2,107 W/m$^2$로 분석되었다. 대류열전달 계수는 액상식품과의 상대속도가 증가함에 따라서 증가하였고, 점도가 증가함에 따라서는 감소하였다.ce of precision/recall of 90.99%/92.52%, and 93.39%/93.41% respectively. 의한 변성에 부분적으로 보호 작용을 나타 낼 것으로 추정된다.경(製麴72時間頃)의 활성(活性)은 보리쌀국(麴), 밀가루국(麴), 찹쌀국(麴), 고구마국(麴)의 순이었다.험 결과 오전용 사료는 관행적인 산란계 배합사료에서 Ca공급제를 제외한 것을 급여하고, 오후용 사료는 Ca공급제를 3배 첨가한 T2처리로 15:00~16:00시에 교체급여를 하면 사료섭취량 감소와 사료비 절감면에서 바람직할 것으로 사료되며, 고에너지-고단백질-저Ca의 분말사료와 저에너지-저단백질-고Ca의 펠렛사료를 혼합급여하면 산란계의 사료

  • PDF

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Hierarchical Analysis of the Application of U-Eco City Services in Urban Space -Focused on the Service Classification by Planning Factors and its Spatial Adaptability - (U-Eco City 서비스의 공간위계별 적용가능성 분석 -계획요소별 서비스 분류와 공간단위 적용성을 중심으로-)

  • Lee, Sangho;Leem, Yountaik;Kim, Heeyoung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.11
    • /
    • pp.458-468
    • /
    • 2012
  • The purpose of this study is to define U-Eco City services and to analyze the possibility and easiness of application in urban space. The most significant meaning of this study is that these results could be used as the design and planning guidelines for integrated U-Eco City. This study progress as follows; First, U-Eco City concept and their services were defined and the spatial units of U-Eco City were distinguished through literature review. Second, U-Eco City spaces are classified into four levels such as building, street, facility and district. Finally, the application of U-Eco city services was analyzed together by the statistical technique of cross-tabulation. 35.7% of U-city services was serviced in urban district and 38.8% of Eco City services was applied to Building. U-City and/or Eco city services were adapted differently according to the urban spatial hierarchy. Those services should be applied in terms of the characteristics of urban space in designing and planning U-Eco City.

A Study on Reduction of Nitrogen Oxide (NOx) and Stability of Incineration Facility by the Food Wastewater Incineration (음식물류 폐수 소각처리에 따른 질소산화물 저감 및 소각설비의 안정성 평가에 관한 연구)

  • Hwang, Seung-Min;Chung, Jin-Do;Song, Jang-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.901-908
    • /
    • 2009
  • We examine the processing method of the food wastewater to direct spray at living waste incinerator. The demoscale stoker system is used as a incineration facility. The results show that it brings effect on the reduction of nitrogen oxide ($NO_x$) concentration as well as the ammonia ($NH_3$) amount in SNCR (selective non-catalytic reduction) by the incineration of food wastewater which is containing a plentiful ammoniac nitrogen ($NH_3$-N). Furthermore, the stability of incineration facility and the extension of operation period is actualized as a improvement of clogging phenomenon on outer wall of water pipe as the 870~$950^{\circ}C$ maintain of exit temperature in a second combustor by spray of the food wastewater. The 26 items of air pollution matter of nitrogen oxide ($NO_x$), sulfur oxide ($SO_x$) and dioxin etc. are measured. The results show that it is under the value of allowable exhaust standard.

Study on Burnability and Reactivity of High Al2O3 Content OPC Clinker for the Use of Industrial Waste (산업부산물 활용을 위한 고Al2O3 함량 OPC 클링커의 소성성 및 반응성에 관한 연구)

  • Kang, Bong-Hee;Choi, Jaewon;Ki, Tae-Kyoung;Kwon, Sang-Jin;Kim, Gyu-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • This study evaluated the burnability and hydration reaction of clinker burned with high Al2O3 content OPC to apply large amounts of industrial by-products in the cement manufacturing process. Specifically, after preparing a clinker with a high C3A content by burning the OPC raw material with a high content of Al2O3 in a laboratory electric furnace, the burnability of the clinker was evaluated through XRD Rietveld analysis and polarization microscopy, and clinker hydration reactivity was reviewed through the Isothermal conduction calorimetry analysis and the cement compressive strength. As a result, the kiln burning temperature for the production of high Al2O3 content clinker lower, and the compressive strength was equal to or higher than OPC. Therefore it was confirmed the possibility to manufacturing energy-saving high Al2O3 content clinker using a large amount of industrial by-products.

Analysis of Volatile Organic Compounds Produced from Incineration of Papers at 600°C (600°C에서 제지류 소각시 발생하는 휘발성 유기화합물 농도분석 연구)

  • 이병규;조정범
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1109-1116
    • /
    • 2002
  • This study analyzed concentrations of volatile organic compounds (VOCs) produced from incineration of papers at $600^{\circ}C$. The papers used in this study included A4 papers (new, printed with ink-jet, printed with carbon), newspapers (printed with bean oil, printed with a general newspaper ink), packaging box, document envelope, single-use paper cup, and cosmetic tissue. Papers were heated from room temperature upto $600^{\circ}C$ providing air inside of the electric furnace and then they were oxidized for 80 minutes at $600^{\circ}C$ maintaining the same air supply. VOCs emitted from the incineration process were sampled using an air sampling pump and bags for 160 minutes and then the components and concentrations of the VOCs were analyzed by a CC-MS. The most prominent chemical structure of the Vous identified from incineration of the papers was furans and then furans were followed by aromatics and aliphatic alkenes. About 40% of the identified VOCs contained double bonds, which have relatively a high ozone (ground level) formation potential, within their molecular structure. Also, some cancer suspecting compounds like benzene, dichlorormethane and chloroform were identified.

Biological Nitrification and Denitrification for Landfill Leachate Containing High Concentration of Ammonium-Nitrogen by using MLE Process (MLE 공정을 이용한 고농도 NH4+-N 함유 침출수의 생물학적 질산화/탈질)

  • Won, Jong-Choul;Namkoong, Wan;Bae, Young-Shin;Lee, Kyung-Shin;Park, Ki-Hyuk;Song, Su-Sung;Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1027-1035
    • /
    • 2000
  • This study was carried out to investigate the treatability of landfill leachate having high concentration of ammonium nitrogen with/without the circulation of media in pilot-scale($48m^3basis$) process. Total nitrogen removal efficiency was relatively increased in the media added process (influent ; $1.230{\sim}2,000mg{\cdot}l^{-1}$, effluent ; $120{\sim}250mg{\cdot}l^{-1}$) compared with the control process. The difference of nitrogen removal efficiency between these processes may be due to that stable growth of nitrifiers attached to the media could be achieved 99.3% of ammonium-nitrogen removal efficiency(without ; 98.2%) and 88.5% of total nitrogen removal efficiency(without ; 85.8%) were shown in media added process, respectively. Also, optimum BOD/ $NH_4{^+}$-N ratio was relatively decreased in the media process compared with the control process. Sludge settleability, on the other hand. was shown better in media added process than in control process. This outstanding sludge settleability in the media added process indicates the compatibility of media(zeolite) to the microorganism and the possibility of using media of biofilm process.

  • PDF

Experimental Study for Establishment of Long-term Monitoring System using Fiber Optical Sensor for Pipeline System for Waste Transportation (광섬유센서를 이용한 쓰레기 이송관로의 장기 계측시스템 구축을 위한 실험적 연구)

  • Kim, Haeng-Bae;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.35-43
    • /
    • 2016
  • Recently, the pipeline system for waste transportation has been increasingly constructed as new solution for the waste collection and disposal system by constantly increasing domestic waste which issued as social problem. The pipeline system is constructed through long distance, so proper long-term monitoring system is necessary which available to detect the damage location for the effective maintenance. In this paper, the experimental study is carried out to evaluate the applicability of optical strain gauge sensor based on FBG for the long-term monitoring system. Three test parameters such as pressure leaking, blockage and deformation are considered as typical damages for real-scale pipeline test specimen. In order to measure flexural and volumetric strain and temperature, three FBG sensors are installed at each monitoring sections. From the test results, this study suggested effective methods of sensor installation and arrangement. Also the sensor spacing for the design of monitoring system using FBG sensor is derived by the correlation of distances from deformation between sensor responses.

Evaluation of Biological Activities on the Extractives of Pinaceae (소나무과 일부 수종의 에탄을 추출물에 대한 생물학적 평가)

  • Ahn, Jeung-Youb;Bae, Jong-Hwan
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.1 s.49
    • /
    • pp.121-125
    • /
    • 2005
  • Most of the cells, specially in the skin, free radicals and reactive oxygen species induced aging, accompanying with diseases. The pinaceae family is very familiar plant with Korean spirit. However, those plants were not estimated for natural products in manufactural process. We employed 4 different plants, Pinus koraienis S et Z. Pinus banksiana LAMBERT. Pinus rigida MILL. Pinus densiflora S. et Z. in pinceae family. The ethanol extracts were prepared for three different parts of plant, wood, bark and leaf, respectively. In this study, we carried out free radical and superoxide radical scavenging assay to investigate the anti-oxidative activity The bark and leaf part of plants showed similar anti-oxidant effect. L-ascorbic acid and $\alpha$-tocopherol at $10{\mu}g/mL$. Also we tried to investigate inhibitory effects of elastase activity in in vitro experiments on pinaceae plant extract as a matters for functional cosmetics. Among those plants, the bark of Pinus rigida MILL. and Pinus densiflora S. et Z. showed inhibitory effect. The cell viability was evaluated with MTT assay. The potential relationship was shown between the cell viability and anti-oxidant effect because the anti-oxidant effects were positively correlated wvith the cell growth in MTT assay. As the results in our experiments, we expect the potential activities of pinaceae as a material of functional cosmetics.