• Title/Summary/Keyword: 생활하수

Search Result 330, Processing Time 0.03 seconds

Evaluation of Performance Index for Optimization of Food Waste Treatment and Recovery Facility (음식물류폐기물 자원화시설 최적화를 위한 이행지표 평가)

  • Kim, Jong-Hwan;Park, Joon-Seok;Phae, Chae-Gun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • This research was performed to evaluate the food waste recovery facility using optimization performance index. In 2014, the generated amount of food waste occupied approximately 27% in total municipal solid waste. The 97.2% of the food waste was recycled and the others were treated through landfill and incineration in the portion of 0.9% and 1.9%, respectively. In food waste recovery facilities of year 2014, the composting and feed facilities were 49.5% and 22.9%, respectively. The feed facility showed higher scores in all technological, environmental, and especially economical evaluations than those of composting facility. As results of overall optimization performance index, the feed facility has higher score of 61.5 than 52.7 of composting facility. It was demonstrated that the feed facility has the advantage, compared with the composting facility.

Design Parameters of Riverbed Filtration Estimated from Geochemical Data (지구화학적 해석을 이용한 하상여과 설계인자에 대한 연구)

  • Cho, Kang-Hee;Kim, Bong-Ju;Ahn, Joong-Hyuk;Rhim, Ki-Sung;Choi, Nag-Choul;Park, Cheon-Young
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.493-502
    • /
    • 2013
  • This study investigates the design parameters for riverbed filtration (RBF) based on the geochemistry of river water and groundwater. The study area consists of alluvium, and the area is readily affected by non-point sources of chemical contaminants in the surface environment; this is expected to affect the design parameters for RBF. River and groundwater samples were collected at three points along the river flow and at nine points along a transect normal to the river, respectively. The geochemical data indicate that the sources of individual chemical contaminants are industrial facilities and agricultural activity near the study area. In addition, The samples are mainly Ca-Na-$HCO_3$, Ca-Cl, and Ca-$HCO_3$-Cl type waters. The design parameters of RBF in the study area should consider K, $HCO_3$, $NO_3$, and Cl. We divided the study area into three regions based on the concentrations of stable nitrogen isotopes: Region A, the origin of the river and denitrification; Region B, denitrification in the flow direction of tributaries; and Region C, the origin of natural soil, sewage, and anthropogenic pollution.

Distribution of Phthalate Compounds in Gwangyang Bay and Seomjin River Estuary (광양만 및 섬진강 하구에서의 프탈레이트 화합물의 분포 특성)

  • 김민선;이동호;심원준;오재룡
    • Korean Journal of Environmental Biology
    • /
    • v.22
    • /
    • pp.47-53
    • /
    • 2004
  • Among the phthalic esters, di-butyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP), which are categorized endocrine disrupting chemicals, account toy up to 80% of the world production. Nine phthalic esters were quantitatively determined in water and in sediment samples from Gawngyang Bay and Seomjin River estuary. This might be the first report in contamination of phthalates in the marine environment of Korea. DBP and DEHP were detected with the high concentration and high frequency, while the other phthnlic compounds were below the detection limits. The aveyage concentyations of DBP and DEBP in sediment from Gawngyang Bay were 33.8 ng g$\^$-1/ and 67.4 ng g$\^$-1/ on a dry weight basis, respectively. The concentrations in surface watey from Seomjin River estuary were in the range of 62.7∼333.8 ng L$\^$-1/ for DBP and 25.6 ng L$\^$-/∼116.1 ng L$\^$-1/ for DBHP. In sediments from Seomjin River estuary, DBP ranged 9.1∼149.3 ng g$\^$-1/, and DEHP 46.3∼156.3 ng g$\^$-1/. Phthalic esters concentrations found in Seomjin River estuary were much less than those in other rivers in Korea. Distribution pattern of DBP and DEHP concentrations in Seonliin River estuary indicates that both compounds aye introduced to Gwangyang Bay through run-off.

Developing Evaluation Index and Item for Water Environment Improvement of Gyeongin ARA Waterway (경인 아라뱃길의 물환경 개선을 위한 오염원인 평가항목 및 지표 개발)

  • Lee, Kyung-Su;Kim, Tae-Hyeong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.469-482
    • /
    • 2018
  • This research has developed the criteria and index for systematically and objectively assessing the quality of river water by fixing the various factors that affect Gyeongin ARA waterway's water quality through analysis with the Delphi Technique and analytic hierarchy program (AHP) Method. Based on the results, the highest criteria are, in order of importance, physical and environmental factors 28%, administrative factors 26%, natural fixed factors 26% and finally, cultural and social factors 20%. The three dimensions of the criteria show that for the internal physical and environmental factors, the most important are the loss of self-purification capacity, and the external factors are Gulpocheon and the sludge deposit due to Gyulhweon-weir the bridge. The facility factor in management was affected by the coagulation and waste water disposal facilities. The problem for the policy and institutional factors was seen in the regulatory area. The aquatic ecology/ point pollution source for the natural fixed factors show that it is due to the polluted water of Gulpo-cheon and the living environment/ non-point pollution source is shown through the inflow water from other rivers. Cultural and social factors show that the economical causes were due to the cargo and passenger flight operations and the external factors of having a lack of sewage treatment equipment have an importance effect. In order to estimate the order of priority through logical evidence and objectivity, future research must be continued on the evaluation indexes to measure the specific methodology and technique needed to improve the Gyeongin ARA Waterway.

Water Quality Improvement Plans based on the Analysis of Pollutant Discharge Characteristics and Water Quality Modelling of Seokmun Reservoir Watershed (석문호 유역 오염물질 배출특성 분석 및 수질모델링에 기초한 수질개선방안 연구)

  • Choi, Moojin;Jung, Woohyeuk;Choi, Jaehun;Kim, Youngil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.581-590
    • /
    • 2017
  • For effective improvement of water quality in Seokmun reservoir, this study implemented various analyses including the tributary water quality and flowrate monitoring, contamination of sediment, investigation of pollution source, selection of priority management target tributary by stream grouping method. The COD concentration of the majority of tributaries in Seokmun reservoir watershed was relatively higher than BOD concentration. The concentration of water pollutants regardless of water quality parameters in Yeokcheon, Dangjincheon, Sigokcheon, Baekseokcheon, small stream in Jinkwanri and Janghangri were higher than the other tributaries. The pollution sources in the Seokmun reservoir watershed were mostly distributed in the population, livestock, and industry. The pollutants, which located in Yeokcheon, Dangjincheon, Baekseokcheon, and small stream in Janghangri selected as priority management target tributary, should be preferentially reduced for improving the water quality in Seokmun reservoir. As the evaluation results of water quality in Seokmun reservoir for the effect of water quality improvement according to various scenarios using water quality model, it was found that the water quality in Seokmun reservoir due to the construction of a wastewater treatment plant for management of pollutants in the watershed would be satisfied the class V of water environment standard in reservoir.

A Study on the Efficient Management Plan of Water Distribution Reservoirs Facility Using 3D Geospatial Information (3D 공간정보를 이용한 배수지시설물의 효율적인 관리방안에 관한 연구)

  • Jung, In Hun;Ro, Young Suk;Choi, Yun Soo;Woo, Sang Yoon;Kim, Chong Mun
    • Spatial Information Research
    • /
    • v.20 no.6
    • /
    • pp.109-118
    • /
    • 2012
  • Recent increasement of metropolitan infrastructure due to rapid expansion and development of urban areas which caused complexity and diversification of management system demands higher cost and effort to manage and maintain the facilities. The reason why it requires continuous and systematic management by national government is that the infrastructure facilities takes important role as it is directly related to public's living. Thus this study suggests an efficient management plan for increasement of work efficiency, cost reduction, and time saving by introducing 3D geospatial information system for water distribution reservoirs which is managed by the Office of Waterworks Seoul Metropolitan Government. This study evaluates and quantifies the range of work improvement using the 3D GIS technology through carrying out a survey targeting people in charge of the Office of Waterworks Seoul Metropolitan Government and other 8 offices. From the result of the research, applying the 3D-GIS improves by 90.32%, 93.55%, and 91.61% in the area of work efficiency, cost reduction, and time saving respectively. Consequently, using 3D GIS in future management of infrastructure could be used as a way of producing base data which supports administrative decision making through statistical and case analysis based on continuous data management. Also it would contribute to improving work efficiency by improving management system through preventing data omission.

Impact of the Pollution on the Benthic Community Environmental impact of the pollution on the benthic coralligenous community in the Gulf of Fos, northwestern Mediterranean (북서 지중해 Fos해역의 해양오염이 해양저서생물군집 Coralligenous Community에 미치는 영향)

  • HONG Jae-Sang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.273-290
    • /
    • 1983
  • A bionomic study of the coralligenous concretionary hard bottom in the northwestern Mediterranean was carried out at four stations : three stations(Arnette, Laurons, Auguette) under the influence of intense multisource pollution(gradient decreasing from north to south) in the Gulf of Fos, west of Marseille, France, and one control station(Moyade islet) in an unpolluted area near Riou island, east of Marseille. Along the increasing pollution gradient from the outer to the inner part of the Gulf of Fos, there is a qualitative and quantitative impoverishment of the fauna. On the whole, the species richness, the numerical abundance. and the species diversity index are all on the decrease. Accordingly, the innermost station in the Gulf of Fos(Auguette) is most heavily affected by the industrial, and to a lesser extent by the domestic wastes, from the nearby industrial complex and urban areas. The impact on the benthic coralligenous community of this serious alteration has been analysed in view of community composition, functional aspect, and ecological stocks. The faunal affinity between stations has been studied by means of the two coefficients : fourfold point correlation coefficient and Jaccard's community coefficient. The upper layer and inferior face communities of the coralligenous concretionary structures are also compared.

  • PDF

Development of an Application System for Efficient Management of Underground Water Supply Facility - Pilot Study in Chonju City - (상수도 지하시설물의 효율적 관리를 위한 응용시스템 개발 -전주시를 대상으로-)

  • 오권호;진철하;이근상;정승현;조기성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.111-120
    • /
    • 2000
  • Water, waste, electric and gas facilities are urban based facilities that needed in our life and are often located in underground. Therefore, underground facilities are more difficult to manage efficiently than ground facilities. It is needed to carry out survey/probe into underground facilities and to build database in order to prevent city-misfortunes being occurred because of negligent management and in order to minimize budget-waste and a traffic jam according to repetition of road excavation constructions. Also, the development of application system is required to manage efficiently underground facility. Chonju city has launched underground water supply facility computerizing project as a part of National Geographic Information System project until December 1998 and executed survey/probe into 402.89 km water supply that is 80 mm up inside central town area 39.6 $km^2$. Also, chonju city built database into 537 km water supply that is 80 mm below based on water supply card without other survey/probe works. Also, existing work process each department is changed into GIS applied work process and underground water supply facility management system is developed by its work process basis. Water supply underground facility management system that is developed is composed of sub-system like base-map management, water supply inspect, water supply management and water supply inquiry, construction work management, administration management and map management. This research presents the procedure and method of underground water supply facility survey/probe and problem being occurred during survey/probe procedure and also show the functions of each sub-systems composing underground water supply facility management system.

  • PDF

The investigation of adsorption properties of filter media for removal efficiency of nitrogen, phosphorus using experimental and density functional theory (실험 및 밀도범함수이론을 이용한 질소, 인 저감 효과 분석을 위한 여재의 흡착 특성 연구)

  • Kim, Taeyoon;Kwon, Yongju;Kang, Choonghyun;Kim, Jongyoung;Shin, Hyun Suk;Kwon, Soonchul;Cha, Sung Min
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.263-271
    • /
    • 2018
  • In this study, we analyzed the removal efficiency of ammonia nitrogen and phosphate dependant on the column depths using various absorbents such as zeolite silica sand, and activated carbon through the column test. In addition, we analyzed electrochemical adsorption behaviors of ammonia nitrogen and phosphate through the quantum mechanical calculation based on density functional theory calculation. Experimental results represent the removal efficiency of ammonia nitrogen and phosphate are zeolite > activated carbon > silica sand, and activated carbon > zeolite > silica sand, respectively. Zeolite shows high adsorption property for ammonia nitrogen over 90%, regardless of the column depth, while activated carbon exhibits high adsorption property for both ammonia nitrogen and phosphate as the column depth for filter media increases. Theoretical findings using DFT calculation for the adsorption behaviors of adsorbents (activated carbon and silica sand) and nutrients ($PO_4{^{3-}}$, $NH_4{^{+}}$) show that activated carbon represented narrower HOMO-LUMO band gap with high adsorption energy, and even more favorable environment for electron adsorption than silica sand, which leads to the effective removal of nutrients.

Discharge Standards of Kitchen-Disposer Wastewater by Treatment Types (디스포저(부엌용 오물분쇄기)-배수 전처리 방식 별 수질기준)

  • Chang, Ho Nam;Jeong, Chang Moon;Kang, Jong Won;Choi, Jin-dal-rae;Park, Young Sook;Ku, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.55-69
    • /
    • 2011
  • Use of disposer at the kitchens of Korean apartments is inevitable in treating their foodwaste having a water content of more than 80%. Also we have to ensure that this extra disposer-foodwaste BOD loadings be treated properly by installing/operating a pre-treatment system before this wastewater enters public sewer system. However, the degree of BOD removal should not be excessive since a BOD/N ratio higher than 5 is required for removing N/P at a municipal wastewater treatment plant. The removal of BOD/N in the pretreatment system rather than BOD alone can be an alternative solution in solving this problem. The particles separated by sedimentation, screen or packed-bed can be anaerobically digested at apartment sites to generate biogas that can be used for simple digester heating and to generate volatile fatty acids (VFAs) for nitrogen removal. We suggest that Korean government grants a temporary license (say for 5 years) to foodwaste treatment companies in collaboration with apartment construction companies which may do business and develop various kinds of disposer-foodwaste treatment systems in diverse wastewater discharge systems of Korean apartments.