• 제목/요약/키워드: 생체 임피던스

검색결과 122건 처리시간 0.021초

전이암 환자의 예후 판단 인자로서 생체전기 임피던스 분석을 이용한 위상각의 역할 (Phase Angle Using Bioelectrical Impedance Analysis for Predicting Survival in Patients with Metastatic Cancer)

  • 윤성수;윤성우;류한성;김은혜;이지영
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.463-470
    • /
    • 2018
  • Objectives: The aim of this study was to identify the validity of phase angle as a prognostic factor for survival in patients with metastatic cancer. Methods: Data of patients with metastatic cancer who visited the Korean medicine cancer center at Kyung Hee University Hospital in Gangdong from April 2016 to February 2018 were collected for this study. The values of phase angle (PhA) and blood hemoglobin (Hb), C-reactive protein (CRP), and serum albumin levels were also investigated by bioelectrical impedance analysis (BIA). Results: In total, 86 patients were analyzed. The cut-off value of the phase angle was determined as 5.0. Univariate and multivariate analysis revealed that phase angle (HR 3.15, 95% CI 1.79-5.54) and CRP (HR 2.15, 95% CI 1.24-3.73) predicted survival with statistical significance. The median overall survival of the low PhA group ($PhA{\leq}5.0$) was 1.8 months (95% CI 0.6-2.9 months) and 7.2 months (95% CI 5.2-9.2 months) in the high PhA group (PhA>5.0)(p<0.001). Conclusions: The phase angle could be an independent prognostic factor for patients with metastatic cancer. Further research is required to confirm these findings and their correlation with other indexes.

생체 전기 임피던스 분석의 한의학적 적용을 위한 연구동향 (Review on Bioelectrical Impedance Analysis in Traditional East Asian Medicine)

  • 배장한;김영민;김근호;김재욱
    • 동의생리병리학회지
    • /
    • 제27권6호
    • /
    • pp.717-729
    • /
    • 2013
  • Bioelectrical Impedance Analysis (BIA) is a non-invasive and low-cost technique that estimates body composition based on the distribution of water and electrolytes in the body by analyzing body's electrical responses to source voltages. In this work, we carried out a systematic literature review on BIA researches in traditional East Asian medicine (TEAM). For comparison, firstly we introduced the concept and principle of BIA, and offered a general overview of research trends in western medical perspectives. We searched through the databases of Oriental Medicine Advanced Searching Integrated System and DataBase Periodical Information Academic for the articles published between 1994 and 2013, with keywords such as 'BIA', 'bioelectrical impedance' and 'impedance'. Among the rough-searched 274 articles, we finally selected 21 articles appropriate to the intended research field. The selected articles were categorized into diagnosis in Sasang medicine, impedance analysis in meridian system, and change of body composition after taking herbal medicine. We found that most of BIA researches in TEAM were preliminary and remained in the peripheral levels which is far behind the western medical research activities. Therefore, more efforts are needed to study BIA in association with major subjects such as pattern identification or physiological/pathological phenomena. In addition, methodological breakthrough of BIA is possible by applying the diagnostic concepts of the TEAM in relation to the balance of Qi and Blood.

부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구 (Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition)

  • 차기철;손정민;김기진;최승훈
    • 대한지역사회영양학회지
    • /
    • 제2권2호
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

생체 임피던스 측정 방법을 한국인의 연령층별 체성분 분석에 관한 연구 (A Study of Age - related Patterns in Body Composition by Segmental Bioelectrical Impedance Analysis for Koreans)

  • 손정민;김정희;신선영;차기철
    • 대한영양사협회학술지
    • /
    • 제7권2호
    • /
    • pp.153-158
    • /
    • 2001
  • This study examined the age-related patterns in body composition cross-sectionally using Segmental bioelectrical impedance analysis(SBIA), specifically its two components, lean body mass(LBM) and body fat mass, in 1,452 men and 1,436 women with an age range of 19 to over 70 years . Mean height of male subjects was 174.1cm at peak in early 20's and was decreased continuously 0.2-0.3 cm every year. Mean weight was greatest between late 20's and 40's, and was decreased quickly in 70's. Body fat mass was increased steadily before 30's and remained thereafter. Because decreasing lean body mass (LBM), percentage of body fat(PBF) increased continuously with aging. Mean height of female subjects was 161.7 cm at peak in 20's and was decreased steadily around 0.2 cm every year and thus an individual's height was decreased approximately 10 cm in their life cycle. Body weight was increased steadily until 50's and then was decreased. Body fat mass was increased continuously and LBM remained constant and thus PBF was increased steadily with aging. SBIA can be used to compare body composition between genders and between ages. In future studies, SBIA could be applied widely to evaluate variations of body composition in subjects with different nutritional problems.

  • PDF

슬관절 운동 평가를 위한 생체 임피던스 측정용 전도성 섬유 센서의 여기 주파수별 특성 평가 (Excitation Frequency Characteristics of a Conductive Fabric Sensor Using the Bio-impedance for Estimating Knee Joint Movements)

  • 이병우;이충근;김진권;정완진;이명호
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1427-1433
    • /
    • 2011
  • This study describes a conductive fabric sensor and determines an optimum excitation frequency of the sensor to evaluate knee joint movements. Subjects were composed of 15 males (age: $30.7{\pm}5.3$) with no known problems with their knee joints. The upper side of subjects' lower limbs was divided into two areas and the lower side of subjects' lower limbs was divided into three areas. The sensors were attached to 1 for 3 spot from a hip joint and to 3 for 4 spot from a knee joint which are the optimum conductive fabric sensor configuration to evaluate knee joint movements. As a result, the optimum excitation frequency for evaluating knee joint movements using conductive fabric sensors was 25 kHz. Average and standard deviation of bio-impedance changes from 15 subjects were $92.1{\pm}137.2{\Omega}$ at 25 kHz. The difference of bio-impedance changes between 25 kHz and 50 kHz was statistically significant (p<0.05) and the difference of bio-impedance changes between 25 kHz and 100 kHz was also statistically significant (p<0.001). These results showed that conductive fabric sensors are more sensitive to measure bio-impedance for evaluating knee joint movements as an excitation frequency decreases.

Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰 (Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results)

  • 김수병;이나라;이승욱;최준영;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

압전고분자 초음파 트랜스듀서와 생의학적 응용 (Piezoelectric Polymer Ultrasound Transducers and Its Biomedical Applications)

  • 하강렬;조영강
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.585-596
    • /
    • 2012
  • PVDF와 P(VDF-TrFE)로 대별되는 압전고분자는 종래의 대표적인 압전재료인 PZT에 비해 전기음향변환효율이 떨어지며 내부손실이 큰 단점은 있으나, 음향임피던스가 물 또는 생체와 비슷하고 수신효율이 우수하며 광대역 특성을 나타내는 등의 장점을 가진 재료이다. 또한 다른 압전재료에 비해 얇은 막으로의 제작이 쉽고, 그 막은 유연하므로 복잡한 곡면을 갖는 고주파 초음파 트랜스듀서 재료로 유용하다. 그러한 특성은 생의학적 응용에 적합한바, 다양한 형태의 초음파 트랜스듀서가 연구 개발되어져 왔다. 본 논문에서는 먼저, 압전고분자막을 이용하여 초음파 트랜스듀서를 설계 제작하는데 있어서 고려해야할 몇 가지 주요사항을 기술하고, KLM 모델을 사용한 해석을 통하여 그 고려사항들이 트랜스듀서의 동작에 미치는 영향을 파악하였다. 다음으로, 의학적 또는 생물학적 응용을 목적으로 초음파 영상을 얻고 있는 몇몇 주요 응용분야에서 사용되는 압전고분자 트랜스듀서의 구조와 그것을 이용하여 얻은 영상의 특징에 대하여 간략히 해설하였다.

전기화학 증착법을 이용한 그래핀 개질 Indium Tin Oxide 전극 제작 및 효소 전극에 응용 (Fabrication of Graphene-modified Indium Tin Oxide Electrode Using Electrochemical Deposition Method and Its Application to Enzyme Electrode)

  • 왕설;시키;김창준
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.62-69
    • /
    • 2022
  • 그래핀은 부피에 비해 표면적이 넓고 뛰어난 기계적 물성과 전기전도성을 가지며 생체적합성이 우수하다. 본 연구에서는 전기화학적 방법을 이용하여 indium tin oxide (ITO) 글래스 슬라이드 표면에 산화그래핀을 증착·환원시킨 전극을 제작하였고 그래핀으로 표면 개질된 ITO의 전기화학적 특성을 조사하였다. 산화그래핀의 증착과 환원에 순환전압전류법을 사용하였다. 주사전자현미경과 에너지 분산형 X-선 분광법을 사용하여 그래핀이 코팅된 ITO 표면을 관찰하였다. 순환전압전류법과 전기화학 임피던스 분광법을 사용하여 제작된 전극들의 전기화학 특성을 평가하였다. 사이클 수와 주사 속도는 산화그래핀 증착과 환원도에 상당한 영향을 미쳤으며 제작된 전극의 전기화학 특성도 달랐다. ITO 전극에 비하여 그래핀으로 표면 개질된 ITO는 전극 계면에서의 전하 전달 저항이 낮았고 더 많은 전류를 생산하였다. 그래핀으로 표면 개질된 ITO 표면에 고정화된 포도당 산화효소는 포도당을 산화시키며 성공적으로 전자들을 생성하였다.

다주파수 생체임피던스 저항을 이용한 당뇨병 환자의 허증 변증 예측 (Prediction of Deficiency Pattern in Diabetic Patients Using Multi-frequency Bioimpedance Resistance)

  • 김가혜;김슬기;차지윤;유호룡;김재욱
    • 동의생리병리학회지
    • /
    • 제36권3호
    • /
    • pp.94-99
    • /
    • 2022
  • The discovery of biomarkers related to pattern identification (PI), the core diagnostic theory of Korean medicine (KM), is one of the methods that can provide objective and reliable evidence by applying PI to clinical practice. In this study, 40 diabetic patients and 41 healthy control subjects recruited from the Korean medicine clinic were examined to determine the human electrical response related to the deficiency pattern, a representative pattern of diabetes. Qi-Blood-Yin-Yang deficiency pattern scores, which are representative deficiency patterns for diabetes mellitus, were obtained through a questionnaire with verified reliability and validity, and the human electrical response was measured non-invasively using a bioimpedance meter. In ANCOVA analysis using gender as a covariate, the 5 kHz frequency resistance and 5-250 kHz frequency reactance were significantly lower in the diabetic group than in non-diabetic control group. In addition, the multiple regression analysis showed a positive correlation (R2=0.11~0.19) between the Yang deficiency pattern score and resistance value for the diabetic group; the correlation was higher at higher frequencies of 50kHz (R2=0.18) and 250kHz (R2=0.19) compared to 5kHz(R2=0.11). In contrast, there was no such significant association in the control group. It implies that bioimpedance resistance measured at finite frequencies may be useful in predicting Yang deficiency, which is closely related to diabetic complications by reflecting the decrease in body water content and metabolism. In the future, large-scale planned clinical studies will be needed to identify biomarkers associated with different types of PI in diabetes.

제주 해녀의 한증과 인체측량, 생체전기임피던스 지표 및 삶의 질과의 연관성 분석 (An analysis of the relationship between the Cold pattern and Anthropometry, Bio Impedance Analysis (BIA) and Quality of Life in Jeju Haenyeo)

  • 이은영;김수정;이시우;차성원;이영섭;문수정
    • 대한예방한의학회지
    • /
    • 제20권3호
    • /
    • pp.67-74
    • /
    • 2016
  • Objectives : The purpose of this study was to analyze the relationship between the Cold-pattern and the quantitative index through the results of an anthropometric method and Bio Impedance Analysis (BIA) of the Haenyeo living in Jeju island. Furthermore, we will examine the effect of Cold-pattern on the quality of life. Methods : BIA indices were acquired directly from Inbody770 and questionnaires were collected by Gallup Korea professional surveyor through face to face interviews. Binary regression analysis and linear regression analysis were used to examine the association between collected data. Results : Total of 175 of people were participated in this study. First, we examined the difference of the indicators in the Cold-pattern group and the non-Cold pattern group by the average comparison of the anthropometry and BIA indices. Most of the non-Cold pattern group showed high quality of life, BIA and anthropometry. In the relationship between Cold-pattern and anthropometry and BIA indices, BMI and PA indices were found to affect the Cold-pattern on a group basis. As the BMI increased by $1kg/m^2$, probability of not being non-Cold pattern was 1.13 times. and as the PA increased by $1^{\circ}$, probability of not being non-Cold pattern was 2.4 times. In the case of EQ5D value, the quality of life of ${\beta}$ was increased by 0.08 in non-Cold pattern (p <.05), EQ5D VAS of ${\beta}$ was also increased by 10.05 (p <.05). Conclusions : This study showed that BMI and PA could be used as a clinical index to evaluate the Cold-pattern as a clinical indicator, and there is a difference in quality of life according to Cold-pattern.