• Title/Summary/Keyword: 생체정보학

Search Result 183, Processing Time 0.031 seconds

In vivo Imaging Flow Cytometer (세포 이미징 기능을 겸비한 생체 유세포 분석기)

  • Lee, Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.9-11
    • /
    • 2007
  • We introduce an in vivo imaging flow cytometer, which provides fluorescence images simultaneously with quantitative information on the cell population of interest in a live animal. As fluorescent cells pass through the slit of light focused across a blood vessel, the excited fluorescence is confocally detected. This cell signal triggers a strobe beam and a high sensitivity CCD camera that captures a snap-shot image of the cell as it moves down-stream from the slit. We demonstrate that the majority of signal peaks detected in the in vivo flow cytometer arise from individual cells. The instrument's capability to image circulating T cells and measure their speed in the blood vessel in real time in vivo is demonstrated. The cell signal irradiance variation, clustering percentage, and potential applications in biology and medicine are discussed.

Genome sequence of Prevotella intermedia strain originally isolated from cervicofacial actinomycosis (경부안면형 방선균증에서 분리된 Prevotella intermedia의 유전체 염기서열 해독)

  • Moon, Ji-Hoi;Jang, Eun-Young;Yang, Seok Bin;Shin, Seung-Yun;Ryu, Jae-In;Lee, Jin-Yong;Lee, Jae-Hyung
    • Korean Journal of Microbiology
    • /
    • v.55 no.1
    • /
    • pp.58-60
    • /
    • 2019
  • Anaerobic Gram-negative bacterium Prevotella intermedia is a part of normal flora of the oral cavity and associated with various types of oral and systemic diseases. We present here a draft genome sequence of P. intermedia ATCC 15032, originally isolated from cervicofacial actinomycosis. The genome is 2,848,426 bp in length and has a GC content of 43.45%. The genome includes 2,358 protein-coding genes, 5 rRNAs, and 43 tRNA. The sequence information will provide important clues in understanding the genome diversity within the bacterial species, and genetic basis for phenotypic differences among P. intermedia strains.

오디오 채널을 이용하는 인증 시스템의 동향

  • Jung, Changhun;Nyang, DaeHun
    • Review of KIISC
    • /
    • v.25 no.3
    • /
    • pp.29-35
    • /
    • 2015
  • 최근 스마트폰의 보급률이 급속도로 증가하면서 사용자가 언제 어디서나 인터넷에 쉽게 접근하여 정보를 얻을 수 있게 되었지만, 그만큼 해커들이 특정한 사용자의 중요한 정보를 훔칠 수 있는 환경이 되었다. 그로 인해 보안 전문가들은 이러한 중요한 정보를 보호하기 위하여 다양한 인증 시스템을 연구하고 있다. 이 논문에서는 키의 입력과 생체정보를 이용한 인증방법에 대한 보안위협과 취약점을 설명하고, 해당 위협을 회피하기 위하여 오디오 채널을 이용한 인증 시스템의 동향을 소개한다.

A Study on Verification of Acupuncture Therapy Effect by Bio-potential Analysis (생체전위 분석에 의한 침구치료 효과 규명에 관한 연구)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.670-678
    • /
    • 2004
  • In oriental medicine, meridian is pathway of bio-energy, and basic an object of diagnosis/therapy. But, in western medicine, meridian has been accepted as action pathway of nerve-endocrine-immune system. Acupuncture effect has been regarded as not effect by transmission of bio-energy but action or response by stimulation. In this paper, when an acupuncturist's bio-energy is passed on(non-insulation) and when is not(insulation), we analysed electric potential on meridian/non-meridian to verify effect of acupuncture therapy. In the results, when bio-energy isn't passed on, bio-potential is reacted to only the first of 4 times acupuncture operating. But when bio-energy is passed on, it is reacted to 4 times, and potential on meridian is higher than that of on non-meridian. Electric potential for same acupuncture operating is different on non/meridians, which implies that physiological construction and bio-energy transmission material is different respectively. When is extracting acupuncture method, potential is higher than that of injection one. It implies that extracting method is more effect than injecting one, in aspect of acupuncture therapy effect. Therefore, acupuncture therapy effect is verified as effect of response by acupuncturist's bio-energy transmission rather than that by only acupuncture stimulus.

Genome sequence of Veillonella atypica KHUD-V1 isolated from a human subgingival dental plaque of periodontitis lesion (사람 치주염 병소의 치은 연하 치태에서 분리된 Veillonella atypica KHUD-V1의 유전체 염기서열 해독)

  • Lee, Jae-Hyung;Shin, Seung-Yun;Lee, Han;Yang, Seok Bin;Jang, Eun-Young;Ryu, Jae-In;Lee, Jin-Yong;Moon, Ji-Hoi
    • Korean Journal of Microbiology
    • /
    • v.55 no.1
    • /
    • pp.77-79
    • /
    • 2019
  • Here we report the genome sequence of Veillonella atypica strain KHUD-V1 isolated from subgingival dental plaque of Korean chronic periodontitis patients. Unlike other V. atypica strains, KHUD-V1 carries two prophage regions and prophage remnants, as well as several genes homologous to prophage-associated virulence factors, such as virulence-associated protein E, a Clp protease, and a toxin-antitoxin system. The isolate and its genome sequence obtained here will aid to understand the diversity of the genome architecture of Veillonella within an evolutionary framework and the role of prophages that contribute to the genetic diversity as well as the virulence of V. atypica.

Research trends of biomimetic covert underwater acoustic communication (생체모방 은밀 수중 음향 통신 연구 동향)

  • Seol, Seunghwan;Lee, Hojun;Kim, Yongcheol;Kim, Wanjin;Chung, Jaehak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.227-234
    • /
    • 2022
  • Covert Underwater Communication (CUC) signals should not be detected by other unintended users. Similar to the method used in Radio Frequency (RF), covert communication technique sending information underwater is designed in consideration of the characteristics of Low Probability of Detection (LPD) and Low Probability of Intercept (LPI). These conventional methods, however, are difficult to be used in the underwater communications because of the narrow frequency bandwidth. Unlike the conventional methods of reducing transmission power or increasing the modulation bandwidth, a method of mimicking the acoustic signal of an underwater mammal is being studied. The biomimetic underwater acoustic communication mainly mimics the click or whistle sound produced by dolphin or whale. This paper investigates biomimetic communication method and introduces research trends to understand the potential for the development of such biomimetic covert underwater acoustic communication and future research areas.

이동통신 주파수 대역 전자파에 대한 생체 반응

  • 박웅양;서정선
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.62-70
    • /
    • 2001
  • 우리 나라 인구의 절반 정도에 해당하는 수의 이동통신 전화가 사용되고 있다. 이동 전화 사용자의 수는 앞으로 더욱 증가할 것이며, 또한 이를 이용한 각종 정보의 교환이 늘어남으로써 개인당 사용량도 늘어날 것으로 생각된다. 사용빈도의 증가와 더불어 이동전화에 의한 뇌종양, 유방암 및 기형 등 각종 인체 질환 발생 가능성에 대한 우려가 늘어나고 있다. 이러한 이동통신 주파수 대역 전자파는 크게 이미 잘 알려진 전자기장이나 자외선, 방사선 등과 인체에 대한 효과가 비슷할 것이라고 생각할 수 있다. 물론 이들은 주파수 대역이 전혀 다르며 이에 따라 서로 다른 물리적 성질을 가지고 있다. 단순히 보유하고 있는 에너지의 크기만으로 비교할 수 있는 것이 아닌 것이다. 그럼에도 불구하고 자외선이나 방사선처럼 전자파도 인체 질환을 유도할 것으로 생각하고 있다. 전자통신제품 사용의 증가에 따라 전자파에 대한 생체 영향에 대한 연구결과들이 발표되고 있다. 특히 이동통신 사용에 따라 암발생이 증가하고 기형이 발생할 수 있다는 역학 및 생물학 연구 결과들이 있었다. 하지만 이 보다 더 많은 수의 논문들이 전자파와 종양 발생이 관련 없다고 얘기하고 있다. 이에 대한 논란은 더 많은 연구와 토론이 필요할 것이다. 정확한 이동전화 주파수대역 전자파가 생체에서 어떻게 작용하는지 알기 위해서는 전자파 자체의 생물리학적 작용기전에 대한 이해가 필요하다. 전자파에 대한 인체 영향을 정확히 분석하기 위해서는 DNA나 단백질 같은 분자수준에서 세포나 실험동물에서 어떤 변화가 발생하는지 분석하는 것이 필요하다. 세포 수준의 연구는 전자파와 한 종류의 세포의 관계를 직접 분석할 수 있다. 세포내에서 DNA나 단백질의 변화는 바로 조직 및 장기내에서의 변화를 의미한다. 하지만 생체내에서는 하나의 세포가 외부 자극에 반응하는 것보다 면역계, 신경계 및 순환계 등 타 장기나 세포의 영향이 존재하는 상황이다. 따라서 세포 수준에서 전자파만의 효과를 장기나 개체내에서 분석하는 전자파에 의한 종양발생 관계를 더 정확히 알 수 있을 것이다. 전자파 중에서 이동전화 주파수 대역에 대한 생체 연구는 많지 않으나 이들로부터 이 주파수 대역의 전자파에 대한 생체 영향 평가 자료를 많이 모을 수 있다. 이러한 자료를 이용하면 핸드폰과 전자파에 대한 위해성 평가를 할 수 있다. 앞으로 다양한 수준에서 생체 영향을 분석함으로써 전자파 노출에 대한 효과를 알 수 있을 것이다.

  • PDF

무자각 사용자 인증을 위한 실용적 뇌파인증 기술 - EEG 기반 인증기술 동향 및 요구사항 분석 -

  • CHO, JIN-MAN;Ko, Han-Gyu;Choi, Daeseon
    • Review of KIISC
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2017
  • 본 논문에서는 생체인식 인증의 한 가지 방법인 뇌파 기반 사용자 인증기술의 최신 기술동향에 대해 고찰하고 해당기술의 실용화를 위해 해결해야 할 기술적 문제점과 요구사항에 대해 분석한다. 뇌파 기반 사용자 인증기술은 최근에 스마트폰, 금융 등 다양한 분야에서 사용되고 있는 기존의 생체인식 인증기술과 비교해볼 때 가변성, 유출 저항성 등의 장점이 있지만, 사용자들로부터 뇌파를 수집하기 위해 필요한 장비의 경제성, 뇌파 수집 행위의 사용자 편의성, 현재까지 발표된 뇌파 기반 사용자 식별 기법들의 안정성 등이 개선되어야 하는 것으로 파악된다. 이와 관련하여 뇌파 측정 장비들의 발전 동향을 살펴보고 해당 장비들의 간소화와 인증정확도 간 트레이드오프(trade-off)와 최신 기계학습 및 인공지능 기술들을 활용한 뇌파 기반 사용자 식별 기법들의 안정성을 위해 해결되어야 할 뇌파의 시간차 문제 및 이에 따른 인증정확도 저하 문제를 규명하고 분석한다.

A Study of Portability and Mobility for Infantry Weapon System (보병용 무기체계의 휴대성 및 이동성에 관한 연구)

  • Chung, SungHak;Son, SungHan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.141-143
    • /
    • 2013
  • 본 연구에서는 인력물자취급시 역사적 관점에서 생리학적 연구방법, 생체역학적 연구방법, 인체심리학적 연구방법들을 검토하여 보병용 무기체계의 휴대성 및 이동성을 분석하였다. 본 연구에서는 휴대성과 이동성 간의 관계를 도식하였다. 단거리의 짧은 기동거리에서는 생체역학적 기준치를, 1-2시간의 중간인 이동에서는 인체심리학적 기준치를, 4시간 혹은 그 이상의 장거리에서는 생리학적 기준치를 적용하여 각각의 가이드라인들을 상호 절충하는 것이 필요한 것으로 판단된다. 본 연구에서는 보병의 물자취급시 4가지 연구방법을 제안하였다.

  • PDF

A Study on Biomechanical Noise Reduction Technique Using Length Information (길이 정보를 이용한 생체 잡음 제거 기술에 관한 연구)

  • Gang, Sin-Gil;Yun, Yong-San;Park, Jae-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1643-1649
    • /
    • 2000
  • When markers attached to body segment are captured by camera, they generally have many noises due to intrinsic biomechanical characteristics. In this study, one technique to reduce these noises is suggested, which constructs a local coordinates of the markers using time-mean lengths of the measured markers and calculates a linear transformation matrix of the interesting body using least square error technique. This matrix is decomposed into two matrices of rotation and flexibility. Suggested method does well for 3 markers or more, and shows consistent results without regard to choice of reference axis.