• Title/Summary/Keyword: 생체임상의학

Search Result 66, Processing Time 0.027 seconds

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Analysis of $^1H$ Magnetic Resonance Spectroscopy Pattern in Invasive Ductal Carcinoma of Breast (유방 침윤성 관상피암에서 수소핵 자기공명분광상의 특성 분석)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.22-28
    • /
    • 2010
  • To evaluate the potential value of $^1H$ Magnetic resonance spectroscopy (MRS) for detecting and characterizing invasive ductal carcinoma of breast. We conducted $^1H$ Magnetic resonance spectroscopy (MRS), using a 3.0T MR scanner, on 40 patients who were histologically diagnosed to have invasive ductal carcinoma (IDC); tumor areas of the patients were designated as experimental samples, and non-tumor areas as control samples. The peak at 3.2 ppm is characteristically intense and observed in 34 cases of the total 40 invasive ductal carcinoma (sensitivity 86.2%; specificity 100%; positive predictive value 100%; negative predictive value 60%). In constrast peak at 1.3 ppm is characteristically intense and observed in normal breast (sensitivity 86.2%; specificity 100%; positive predictive value 100%; negative predictive value 60%). The study shows that $^1H$ MRS can effectively discriminate invasive ductal carcinoma from normal breast in most cases. It also demonstrates the feasibility of localized in vivo $^1H$ MRS technique as a new diagnostic modality in the detection of breast tumor.

The Variation of Tagging Contrast-to-Noise Radio (CNR) of SPAMM Image by Modulation of Tagline Spacing (Tagline 간격의 조절을 통한 SPAMM 영상에서의 Tagging 대조도 대 잡음비의 변화)

  • 강원석;최병욱;최규옥;이상호;홍순일;정해조;김희중
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.224-228
    • /
    • 2002
  • Myocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. However, the accuracy of the estimation of tag intersection can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) in in-vivo study. Two healthy volunteers were undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner. Horizontally modulated stripe patterns were imposed with a range from 3.6 to 9.6 mm of tagline spacing. Images of the left ventricle(LV) wall were acquired at the mid-ventricle level during cardiac cycle with FE-EPI (TR/TE = 5.8/2.2 msec, FA= 10$^{\circ}$. Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of narrow tagline spacing than in case of wide tagline spacing. In the same heart phase, CNR was increased corresponding with tagline spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing. The results indicated that the optimization of tagline spacing provides better tagging CNR in order to analyze the myocardial motion more accurately.

  • PDF

Naturopathy Theory and Mechanism of Breathing Massage for Life Care (라이프 케어를 위한 호흡마사지법의 자연치유 이론기전)

  • Kim, Meong-Ju;Kim, Hye-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1104-1111
    • /
    • 2017
  • In this study, the authors aimed to give careful consideration to the circulation of bioenergy (Qi) by using cardiorespiratory massage technique. Finding enlightenment in harmony with nature thousands of years ago, our ancestors created Qi using natural breathing and tried to achieve good health and long life by controling the up and down movement. Experiencing the importance of the abdomen during the hungry times, also, grandmothers cured diseases by rubbing the abdomen, which is the ocean of life with their soft, soothing touch of hand. Naval breathing therapy was formed, based on natural breathing, emotional recognition of grandmothers' soft, soothing touch, and the Theory of Unified Reason and Energy that is the key of Oriental medicine. Natural breathing and Yakson massage are kinds of naturopathy to change body and mind, cure diseases naturally, and maintain the improvement in physical functions by taking care of the abdomen through the creation of Qi and the up and down movement and keeping dynamic balance between the natural world and the inside and outside of human body. It is anticipated that this study could contribute to the practical spread for an active application of naval breathing therapy and be broadly used in scientific clinical researches.

A Study on Development of ECS for Severly Handicaped (중증 장애인을 위한 생활환경 제어장치개발에 관한 연구)

  • 임동철;이행세;홍석교;이일영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.427-434
    • /
    • 2003
  • In this paper, we present a speech-based Environmental Control System(ECS) and its application. In the concrete, an ECS using the speech recognition and an portable wheelchair lift control system with the speech synthesis are developed through the simulation and the embodiment. The developed system apply to quadriplegic man and we evaluate the result of physical effect and of mental effect. Speech recognition system is constructed by real time modules using HMM model. For the clinical application of the device, we investigate the result applied to 54-years old quadriplegic man during a week through the questionnaires of Beck Depression Inventory and of Activity Pattern Indicator. Also the motor drive control system of potable wheelchair lift is implemented and the mechanical durability is tested by structural analysis. Speech recognition rate results in over 95% through the experiment. The result of the questionnaires shows higher satisfaction and lower nursing loads. In addition, the depression tendency of the subject were decreased. The potable wheelchair lift shows good fatigue life-cycle as the material supporting the upper wheelchair and shows the centroid mobility of safety. In this paper we present an example of ECS which consists of real-time speech recognition system and potable wheelchair lift. Also the experiments shows needs of the ECS for korean environments. This study will be the base of a commercial use.

Trends in the Use of Artificial Intelligence in Medical Image Analysis (의료영상 분석에서 인공지능 이용 동향)

  • Lee, Gil-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.453-462
    • /
    • 2022
  • In this paper, the artificial intelligence (AI) technology used in the medical image analysis field was analyzed through a literature review. Literature searches were conducted on PubMed, ResearchGate, Google and Cochrane Review using the key word. Through literature search, 114 abstracts were searched, and 98 abstracts were reviewed, excluding 16 duplicates. In the reviewed literature, AI is applied in classification, localization, disease detection, disease segmentation, and fit degree of registration images. In machine learning (ML), prior feature extraction and inputting the extracted feature values into the neural network have disappeared. Instead, it appears that the neural network is changing to a deep learning (DL) method with multiple hidden layers. The reason is thought to be that feature extraction is processed in the DL process due to the increase in the amount of memory of the computer, the improvement of the calculation speed, and the construction of big data. In order to apply the analysis of medical images using AI to medical care, the role of physicians is important. Physicians must be able to interpret and analyze the predictions of AI algorithms. Additional medical education and professional development for existing physicians is needed to understand AI. Also, it seems that a revised curriculum for learners in medical school is needed.

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Morphometric Analysis of Distances between Sacral Hiatus and Conus Medullaris Using Magnetic Resonance Image in Korean Adult (자기공명영상을 이용한 한국 성인의 엉치뼈틈새와 척수원뿔 사이 거리 연구)

  • Park, Tai Soo;Hwang, Byeong-Wook;Park, Sang-Joon;Baek, Sun-Yong;Yoon, Sik
    • Anatomy & Biological Anthropology
    • /
    • v.29 no.4
    • /
    • pp.145-154
    • /
    • 2016
  • The purpose of this study was to provide basic biometric data on Korean adults through magnetic resonance imaging (MRI)-based measurements of the distances between the apex of sacral hiatus (SH) and the termination of dural sac (DS), and between SH and conus medullaris (CM) because they are critical to the performance of epidural neuroplasty. A total of 200 patients(88 males and 112 females) with back pain, who had no spine fracture, significant spinal deformity, and spondyloisthesis were selected for this study. The subjects were of mean age 54.3 (20~84) years and mean height 161.3 cm (135~187). T2-weighted MRI images were used for correlation analysis to evaluate the relationships between the distances, and variables such as sex and height. In all patients, the mean distance between SH and DS was $62.8{\pm}9.4mm$ and the mean distance between SH and CM was $232.2{\pm}21.8mm$. The minimum distance and the maximum distance between SH and DS were 34.8 mm and 93.9 mm respectively, and the minimum distance and the maximum distance between SH and CM were 155.0 mm and 284.0 mm respectively. In female patients, both the distances between the SH and DS, and between SH and CM were shorter when compared to those of the male patients(p<0.05). Both the distances between SH and DS and between SH and CM showed a significant correlation with height(p<0.01). The results of this study will provide a useful biometric data on the distances between SH and DS and between SH and CM in Korean in ensuring clinical safety and in the development of more effective catheterization techniques for epidural neuroplasty in Korean.