Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

Dose Reduction Effect by using Compression Band during Chest CT Examination in Female Patients (여성의 흉부 CT 검사 시 압박밴드 사용에 따른 선량 감소효과)

  • Kim, In Soo;Cho, Yong In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.445-453
    • /
    • 2021
  • CT scan is reported to have a high risk of cancer due to a relatively high dose among medical radiological examinations. In particular, exposure to radiation to the breast, which is sensitive to radiation, is inevitable during a chest CT scan for female patient. In this study, the dose reduction effect of wearing a compression band during chest CT scans in women was evaluated, and the lifetime attributable risk due to the effective dose exposed during the CT scan was estimated. As a result, when the compression band was used, the effective tube current decreased as the outer perimeter of the chest became smaller, and it was analyzed that the CT dose index and effective dose were also reduced. In addition, the lifetime attributable risk by chest CT scan was found to reduce the cancer risk by 3.2 per 100,000 for all cancers, 0.2 per 100,000 for solid cancer, and 0.8 per 100,000 for breast cancer, based on women in their 30s when using a compression band. It is judged that the risk of cancer can be reduced through the use of appropriate scan parameters and dose optimization measures such as compression bands for future CT examinations.

Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention (관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가)

  • Kang, Yeong-Han;Kim, Bu-Sun;Park, Jong-Sam
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.213-221
    • /
    • 2010
  • The Purpose of this study was to determine the effective dose to an average patient from Coronary Angiography (CA) and Percutaneous Coronary Intervention (PCI). And to estimate the lifetime attributable risk (LAR) of cancer associated with radiation exposure from CA and PCI. The dose-area product (DAP) values to the patient were recorded from 60 CA and 58 PCI. A Monte Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Lifetime attributable risks were estimated with models developed in the National Academies' Biological Effects of Ionizing Radiation VII report. The mean DAP values was $53.76\;Gy{\cdot}cm^2$ for CA and $165.82\;Gy{\cdot}cm^2$ for PCI. Mean effective dose were 1.28 mSv in CA, 3.94 mSv in PCI. Results of Calculate organ dose, lung doses was 2.17 mSv in CA and 6.71 mSv in PCI. Female breast doses was 5.45 mSv in CA and 16.82 mSv in PCI. LAR estimates for CA varied from 1 in 1,508 for man to 1 in 1,357 for women. In PCI procedure varied from 1 in 553 for man to 1 in 482 for women. DAP can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. These dose estimates derived from our simulation models suggest that CA and PCI are associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, PCI than for man, CA.

Methodology on the Safety Goal Setting of Reactor Operation based on the Radiogenic Excess Cancer Risk in Korea (한국인의 초과 방사선 암 위험도 평가에 근거한 국내원전의 안전목표치 설정 방법론)

  • Chang, Si-Young;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.131-142
    • /
    • 1999
  • By using the Korean demographic data and the modified relative risk projection model given in the Committee on the Biological Effect of Ionizing Radiation (BEIR) report-V under the U.S. National Academy of Science, the radiogenic excess risk in Korean population has been evaluated. On the basis of this risk, a safety goal for the safe operation of domestic nuclear power plants has been further derived in terms of personal dose. The baseline risk of death due to all causes in Korea and the trivial risk level, which the society considers safe, were estimated to be $5.2{\times}10^{-3}$ and $5.2{\times}10^{-6}$, respectively. The radiogenic excess cancer risk in Korea has been estimated to be $5.2{\times}10^{-3}$ for tie case of acute exposure to 0.1 Gy and $3.7{\times}10^{-3}$ for the case of chronic lifetime exposure to 1.0 mGy/y. On the basis of these risks estimate, the resulting safety goal for one year opeation of a reactor was 0.05 mSv, which is quite identical with the ALARA guideline prescribed by the USNRC in the Appendix I, 10CFR50.

  • PDF

Healthy Korea 2010 : Role of the Health Educator (Healthy Korea 2010추진과 보건교육 인력 활용 전략)

  • Choi, Eun-Jin
    • Proceedings of The Korean Society of Health Promotion Conference
    • /
    • 2004.10a
    • /
    • pp.89-109
    • /
    • 2004
  • The Korean Government has produced the Health Plan 2010 aimed at setting up healthy Korea objectives, policies on preventing chronic diseases, reshaping the country's health and medical infrastructure. The policy goal targets the people's healthy life expectancy at 75 by 2010, and includes healthy life practice measures including health education, health improvement services, and disease management measures, in achieving the objectives. Also, the plan provides life cycle-based health improvement and disease prevention services, as well as pushes ahead with projects with greater ripple effects in each area. To this end, the government is simultaneously pushing to operate an experts-centered health promotion committee and establishing the infrastructure including the augmentation of national health improvement funds. Through its Health Plan 20 I 0, the Korean Government will exert efforts to achieve its policy objectives as addressed in the measures by enhancing the national potential health and providing systematic disease prevention services.

  • PDF

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.