• Title/Summary/Keyword: 생물학적 고도 처리

Search Result 203, Processing Time 0.035 seconds

The Biological Degradation of High Concentration of Trichloroethylene (TCE) by Delftia acidovornas EK2 (Delftia acidovorans EK2에 의한 고농도 Trichloroethylene (TCE)의 생물학적 분해 특성)

  • Park, Woo-Jung;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.183-191
    • /
    • 2010
  • In this study, we isolated 179 bacterial strains using benzene, phenol, ethylbenzene, aniline, cumene, toluene as growth substrate from TCE contaminated soils and wastewaters. All the 179 strains were screened for TCE (30 mg/L) removal (growth substrate 0.2 g/L, $30^{\circ}C$, pH 7, cell biomass 1.0 g/L (w/v)) under aerobic condition for 21 days. EK2 strain using aniline showed the highest removal efficiency (74.4%) for TCE degradation. This strain was identified as Delftia acidovorans as the results of API kit, 16S rDNA sequence and fatty acid assay. In the batch culture, D. acidovorans EK2 showed the bio-degradation for TCE in the various TCE concentration (10 mg/L to 200 mg/L). However, D. acidovorans EK2 did not show the bio-degradation in the TCE 250 mg/L. D. acidovorans EK2 also show the removal efficiency (99.9%) for 12 days in the low concentration (1.0 mg/L). Optimal conditions to degrade TCE 200 mg/L were cell biomass 1.0 g/L (w/v), aniline 0.5 g/L, pH 7 and $30^{\circ}C$. Removal efficiency and removal rate by D. acidovorans EK2 strain was 71.0% and 94.7 nmol/h for 21 days under optimal conditions. Conclusion, we expect that D. acidovorans EK2 may contribute on the biological treatment in the contaminated soil or industrio us wastewater.

Practical Demonstration of YPNR Process to Elimination the Total Nitrogen Ingredient in Sewage (하수 내 총질소 성분 제거를 위한 YPNR 공정의 실증 연구)

  • Lim, Eun-Tae;Jeong, Gwi-Taek;Bhang, Sung-Hun;Kim, Yong-Un;Park, Jae-Hee;Park, Seok-Hwan;Park, Don-Hee
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.291-295
    • /
    • 2009
  • This study performed verification experiment for the removal of total nitrogen in sewage from a Town M village sewage treatment plant using YPNR processes. The total nitrogen discharged after the denitrification process was maintained at a level of 8-15 mg/L, which results in the total nitrogen removal efficiency above 68% on average. The total nitrogen components in discharged water consisted of 16% of ammonia nitrogen, 6% of nitrite nitrogen, and 77% of nitrate nitrogen, which reaches a 95% nitrification efficiency. Hence, the YPNR advanced treatment process used in this study can be successfully applied to sewage treatment.

Evaluation of Biological Organic and Nutrient Removal Performance in Intermittent MBR Systems by Computer Simulation (컴퓨터 시뮬레이션을 이용한 간헐폭기 MBR시스템에서의 유기물 및 영양염류 처리 성능 평가)

  • Yoo, Hosik;Rhee, Seung-Whee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.3
    • /
    • pp.82-92
    • /
    • 2013
  • The Intermittent Aeration MBR systems have the advantage of controlling reaction time by changing aeration period and are one of economic BNR systems since these processes do not require MLSS recirculation that demands capital and operation costs. In this study, two intermittent aeration MBR systems were studied by computer simulation: an intermittent aeration MBR system that had both 1hr/1hr and 4hr/4hr aeration/unaeration periods at intermittent reactor and NEW INTERMITTENT-process that was an energy saving process and certified as a new process by Korean government. Since DO concentration reached only at 0.23mg/L at intermittent reactor when it was aerated, the Intermittent aeration MBR system having 1hr/1hr aeration/unaeration period showed simultaneous nitrification/denitrification and had the highest nitrogen and phosphorus removal efficiencies that were 57% and 55%, respectively. Since this study was based on the constant influent flow and characteristics, more studies are needed to define the operational characteristics of intermittent aeration MBR systems under dynamic influent conditions.

Comparison of energy efficiency by electrode materials and structure in bench scale bioelectrochemical anaerobic digestion (Bench scale 생물전기화학적 혐기성소화에서 전극재질 및 구조에 따른 에너지효율 비교)

  • Yang, Hyeon Myeong;Cheon, A In;Kim, Min Ji;Cha, Ji Hwan;Jun, Hang Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.396-396
    • /
    • 2022
  • 생물전기화학적 혐기성소화(Bioelectrochemical anaerobic digestion; BEAD)는 소량의 전압공급을 통해 고농도 하·폐수의 효과적인 처리 및 에너지 회수가 가능한 처리방법으로, 기존 하·폐수처리공정(활성슬러지 및 그 변법)에서 벗어나기 위한 방법 중 하나로 연구되고 있지만, 내부저항 및 전극구조에 따른 물질전달저해로 인해 소규모 연구 위주로 진행되었다. 하지만 stainless steel(SS) 등 내부저항을 완화할 수 있는 전극재료 및 전극구조 개선 연구가 진행됨에 따라 BEAD 적용규모가 증가하는 추세이며, 본 연구에서는 100 L의 용량에서 전극재질 및 구조에 따른 적용적합성을 에너지효율 비교를 통해 평가하였다. 반응조는 비교를 위한 AD, 반응조 내부에 전극을 설치한 BEAD, 반응조 외부에 전극이 포함된 반응조를 추가한 ABEAD로 구성하였으며, AD 및 BEAD는 기계적 교반, ABEAD는 기계적 교반 및 펌프를 통한 bulk 용액 순환으로 물질전달이 이뤄졌다. 또한 BEAD는 탄소계 전극, ABEAD는 SS계 전극을 사용하였으며 두 반응조 모두 0.4 V의 전압을 공급하였다. 실험조건은 유효용량 100 L, 유기물부하율 3 kg/m3/d, HRT 20 days 및 중온소화(35℃)으로 운전하였다. 실험결과 AD, BEAD 및 ABEAD의 유기물제거율은 각각 평균 68.1 %, 68.9 %, 74.9 %로 전극 및 반응조의 분리를 통해 물질전달을 개선한 ABEAD에서 증가하였다. 에너지 생성량의 경우 AD에 비해 BEAD는 평균 229 kJ/d, ABEAD는 309 kJ/d가 추가 생성되었으며 유기물제거율이 높은 ABEAD에서 더 높은 에너지생산이 이뤄졌다. 마지막으로 전압공급으로 인한 에너지소비량은 BEAD는 평균 3.4 kJ/d, ABEAD는 평균 0.9 kJ/d로 전극의 낮은 생물적합성으로 인해 전극에서의 생화학반응이 적은 ABEAD가 에너지소비량이 낮았다. 따라서 본 연구에서는 SS 전극의 사용가능성 및 전극구조 개선에 따른 에너지효율성 향상을 확인할 수 있었으며, 추후 연구에 활용할 수 있을 것으로 기대된다.

  • PDF

Biological Nitrification and Denitrification for Landfill Leachate Containing High Concentration of Ammonium-Nitrogen by using MLE Process (MLE 공정을 이용한 고농도 NH4+-N 함유 침출수의 생물학적 질산화/탈질)

  • Won, Jong-Choul;Namkoong, Wan;Bae, Young-Shin;Lee, Kyung-Shin;Park, Ki-Hyuk;Song, Su-Sung;Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1027-1035
    • /
    • 2000
  • This study was carried out to investigate the treatability of landfill leachate having high concentration of ammonium nitrogen with/without the circulation of media in pilot-scale($48m^3basis$) process. Total nitrogen removal efficiency was relatively increased in the media added process (influent ; $1.230{\sim}2,000mg{\cdot}l^{-1}$, effluent ; $120{\sim}250mg{\cdot}l^{-1}$) compared with the control process. The difference of nitrogen removal efficiency between these processes may be due to that stable growth of nitrifiers attached to the media could be achieved 99.3% of ammonium-nitrogen removal efficiency(without ; 98.2%) and 88.5% of total nitrogen removal efficiency(without ; 85.8%) were shown in media added process, respectively. Also, optimum BOD/ $NH_4{^+}$-N ratio was relatively decreased in the media process compared with the control process. Sludge settleability, on the other hand. was shown better in media added process than in control process. This outstanding sludge settleability in the media added process indicates the compatibility of media(zeolite) to the microorganism and the possibility of using media of biofilm process.

  • PDF

Soybean Wastewater Treatment by Activated Sludge Process (고농도 대두가공폐수의 처리를 위한 개선 활성슬러지법)

  • Cho, Kwon-Ik;Lee, Jeoung-Su;Lee, Tae-Kyoo;Kim, Jong-Hwa
    • Applied Biological Chemistry
    • /
    • v.45 no.1
    • /
    • pp.25-29
    • /
    • 2002
  • The kernel of wastewater treatment by activated sludge is elimination of organic substances and maintenance of well-flocculated sludge sedimentation. By the conventional activated sludge treatment, the optimum F/M ratio of soybean wastewater treatment was 0.24 (kg-BOD/kg-MLVSS day) and sludge bulking was generated at 0.48 (kg-BOD/kg-MLVSS day). To improve the treatment capacity and operation quality in higher loading of soybean wastewater, influent pH was constantly controlled by 9.0 using NaOH as a coagulant agent. In this process, higher loading up to 2.88 (kg-BOD/kg-MLVSS day) was possible and SVI was maintained under 150 without bulking. This was equivalent to 7.2 times higher than maximum permissible load of the conventional activated sludge process.

Standard Research for an Anti-Bacterial Effectivity in Conservational Environment of Organic Cultural Properties (유기물 문화재 보존환경의 효율적 미생물 제거를 위한 표준화 연구)

  • Seo Min-Seok;Chung Yong-Jae;Hong Jung-Ki;Song Ji-Ae
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.252-254
    • /
    • 2005
  • 박물관 수장고와 전시실 내의 유기물 문화재는 실내공기에 부유하고 있는 먼지와 곰팡이로 인해 생물적 피해를 받는다. 미생물로 인한 피해를 줄이기 위하여 박물관에서는 환경 조절법을 시행하거나 수장고와 전시실 내에 보존약제를 놓거나 또는 훈증 처리를 통한 방균 방제처리를 시행하고 있다. 미생물의 발생은 문화재 표면의 착색, 재질 분해, 변질 등을 야기한다. 본 연구는 위에 제시된 방법 외에 공기청정기를 이용하여 실내 부유 미생물 수를 줄여 유기물 문화재의 피해를 줄일 수 있는지를 알아보았다. 국립문화재연구소 내 생물과학실의 실험실 한 곳을 임의로 지정하여 공기청정기를 설치하기 전 곰팡이의 수를 측정하고, 공기청정기를 설치한 후의 곰팡이 변화를 4일 간격으로 측정하였다. 또한, 공기 중의 ???r성분 분석을 위하여 가스크로마토그래피(Gas Chromatography)를 이용하였다. 측정결과 곰팡이의 수는 대체적으로 감소하였으며, 채취한 곰팡이를 배양하여 동정을 실시하였다. 곰팡이 동정은 현미경을 통한 형태학적 분류와 ITS(Internal Transcribed Sequence)를 이용한 rDNA(Ribosomal DNA) PCR(Polymerase Chain Reaction)분석 두 가지 방법을 이용하여 동정하였다.

  • PDF

Advanced Treatment of Sewage Using Waste Plastic Vessel Media (폐플라스틱용기 미디어를 활용한 오수고도처리)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-61
    • /
    • 2006
  • The object of this study was to develop an advanced method for fluid flow and oxygen transmission and increase adhesive property of microorganism to waste plastic vessel that was made of microorganism media. Through lab scale experiments, we found the optimum packed media volume rate and method, and when the optimum condition was applied to pilot plant, we confirmed possibility of advanced treatment. The sewage that was used in the test was the sewage disposal facility established in C and K elementary schools, which utilized waste plastic media oxidation engineering method. Analysis showed that removal efficiency of organic matter, SS, T-N and T-P was very high, that the sewage disposal facility maintained stability of treatment when changeable load of raw sewage flowed in.

Development of customized and energy-saving process for wastewater reuse utilizing UF/NF membrane (UF/NF 분리막을 활용한 수요자 맞춤형 / 에너지 절약형 재이용수 공정기술 개발)

  • Hong, Min;Hwang, Hyun-Seob;Park, Ock-Kwon;Kim, Yong-Lim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.712-712
    • /
    • 2012
  • 하 폐수 처리방류수를 물리적, 화학적 그리고 생물학적 기술을 이용하여 처리한 후 재활용수로 이용하고자 하는 새로운 노력들이 진행되고 있지만 국내의 경우 방류수 재활용 기술과 처리수의 재이용에 대한 평가기술이 선진국에 비해 초기 단계에 있어 이 분야에 대한 적극적인 기술개발이 요구된다. 막 분리 기술을 이용한 처리 수는 소독 등의 추가적인 처리 없이 살수용수나 수경용수로 이용이 가능하며, 잔류염소를 유지시킬 경우 화장실 세정용수로의 이용도 가능하며, 또한 후처리 기술을 조합하면 고급 공업용수 등으로 사용가능하므로 선진기술로서 수요조건에 맞게 전 후 처리를 조합한 수요자 맞춤형 재이용수 공정기술을 개발할 필요가 있다. 이에 효율적인 하 폐수 재이용을 이용하여 농업용수(축산 음용수, 첨단 수출원예용수, 첨단 농업용수, 농산업 클러스터 복합 곡물 용수), 원예용수(원예단지), 공업용수 등의 다양한 용도에 활용 가능한 수요자 맞춤형 모듈 및 공정 개발을 수행하였다. 개발된 공정은 AOP 및 막 세정 시스템을 이용한 새로운 공정으로, AOP 시스템은 전기 이온 모듈을 통해 OH 라디칼을 생성 및 염분 제거 효율을 극대화 하여 오염 물질을 산화시키는 공정이며, FDA 시스템은 탁도가 높은 원수가 과다 유입 될 경우 후단 여과 막의 부하를 줄이는 역할을 하며, 부유 물질을 여과 시킨다. 막 세정 시스템은 미세 입자를 구성된 기포를 이용하여 눈에 보이지 않는 곳 까지 세척하며, 살균 작용을 하며, 분리 막의 성능을 증대 시킨다. 이어 UF 분리 막 시스템은 원수의 미세불순물, 박테리아, 스케일 물질 등을 제거하며, NF 시스템을 통하여 미립자, 박테리아 유기 화합물 및 2가 염 제거를 하여 재이용수를 생산하는 공정을 개발하였다. 개발된 수요자 맞춤형 공정은 하수 재이용 기술의 이용 목적 및 수요자별로 맞춤형으로 운영이 가능하며, 개발된 세척 기술은 분리 막 세정 유지관리비 및 에너지를 저감 할 수 있으며, 현장 적용의 실증화 과정을 거쳐 공정 기술을 신뢰도를 향상하고, 보유 기술을 수요자 맞춤형으로 업그레이드함으로써 기술의 경쟁력 및 고품질의 하수 재이용 기술의 새로운 방향을 제시 할 수 있을 것으로 판단된다.

  • PDF

A Study on the Application of Manganese Oxidizing Bacteria for Manganese Treatment in Acid Mine Drainage (산성광산배수의 망간처리를 위한 MOB 적용에 관한 연구)

  • Lee, Kang Yu;Jang, Min;Park, In Gun;Um, Tae Young;Lim, Kyeong Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.8
    • /
    • pp.564-570
    • /
    • 2013
  • Domestic treatment facilities for acid mine drainage (AMD) mostly used a passive treatment process. But some passive treatment facility discharged high manganese concentrations because it is required high pH (>9) for abiotic oxidation of Mn(II) to Mn(IV). This study was focused on the feasibility of biological manganese treatment using the manganese-oxidizing bacteria (Pseudomonas sp. MN5) from AMD and economical application method of it. To investigate the various conditions of water quality the most part of the experiments were based on batch test. And result of it showed that maximum manganese oxidation rate were $10.4mg/L{\cdot}h$ at the pH7. We also performed small column tests in which MOB were attached to the functional polyurethane (FPU) media containing alkaline chemicals. Manganese concentration decreased 42 mg/L to below 6 mg/L. But anaerobic condition formed by excessive bacterial respiration in column resulted in increasing effluent manganese concentration.