• Title/Summary/Keyword: 생리적 동요도

Search Result 10, Processing Time 0.025 seconds

Comparison of the fatigue limit of fiber-reinforced composites and stainless steel wires when attached to the tooth surface for anchorage reinforcement (고정원 강화를 위해 치면에 부착한 fiber-reinforced composite과 스테인리스강 와이어의 피로한도 비교)

  • Kim, Moon-Jung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.302-311
    • /
    • 2005
  • This study was performed to compare the fatigue limit of stainless steel wires and Fiber-reinforced composites (FRC) under conditions of permitting physiologic tooth movement. and to evaluate the clinical value of FRCs which was used to reinforce the anchorage unit. The stainless steel wire groups were divided into round and rectangular wire groups. The FRC groups were divided into uni-directional and woven groups, with resin coating and without resin coating in the Proximal area After the number of cycles to failure of each of the 6 groups were measured within the $5{\times}10^5\;cycle$ fatigue limit simulating the orthodontic treatment period. the fatigue limit of each group was compared with each other The findings of this study were as follows. In stainless steel wires, the fatigue limit of rectangular wires were higher than that of round wires. But there was no statistically significant difference (p>0.05). In FRCs with resin coating and without resin coating in the interproximal area, the fatigue limit of uni-directional type was higher than that of the woven type (p<0.05). In uni-directional and woven type FRCs, the fatigue limit of FRC with resin coating in the interproximal area was higher thar that of FRC without resin coating (P<0.05) As the FRCs and stainless steel wires did not fracture until the $5{\times}10^5\;cycle$ fatigue limit which clinically is useful. it is sufficient to use FRC and stainless steel wire for reinforcing anchorage. When esthetics is important and the attachment of additional devices are necessary. it seems sufficient to use FRC as anchorage reinforcement.

Maxillary full-arch fixed dental prosthesis of the elderly patient with worn dentition (마모된 치열을 지닌 고령 환자의 상악 전악 고정성 수복 증례)

  • Lee, Jae hyun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.154-162
    • /
    • 2017
  • Tooth wear, one of the physiological changes in the elderly patient's mouth, generally does not require treatment, but requires prosthodontic restoration when occlusal disharmony, poor masticatory function, pulp exposure occurs. One of the primary considerations in prosthodontic restoration for tooth wear is vertical dimension. It is necessary to make an accurate diagnosis and analysis, correct judgement of the interdental relationship for predictive treatment plan. A step-by-step approach considering dental care for aged is also required. In this case, a 93-year-old male patient presented with worn dentition and mobility of existing fixed dental prosthesis. After diagnosis and evaluation, maxillary rehabilitation without any change in the occlusal vertical dimension was performed and this shows satisfactory results both functionally and morphologically.

Flexibility of resin splint systems for traumatized teeth (외상성 치아모형에서의 레진 스플린트 시스템의 유연성 비교연구)

  • Park, Jin-Hong;Shin, Joo-Hee;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.389-393
    • /
    • 2017
  • Purpose: The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system. Materials and methods: Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated 'injured teeth' with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (${\alpha}=.05$). Results: Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05). Conclusion: Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

The efficacy of biofeedback in reducing cybersickness in virtual navigation (생체신호 피드백을 적용한 가상주행 환경에서 사이버 멀미 감소 효과)

  • 김영윤;정찬용;김은남;윤정민;서동오;고희동;김현택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.90-94
    • /
    • 2002
  • 이전연구에서 가상현실에 몰입하는 동안 넓은 시야 (Field of view: 150$^{\circ}$)와 빠른 운행속도 (70 km/sec)가 사이버멀미를 심화시킨다는 결과를 얻었다: 피험자의 90%가 좁은 시야 (50$^{\circ}$)와 느린 운행속도 (30 km/sec)에서 사이버멀미 증상이 적었다. 본 실험에서는 피험자가 생리적인 동요를 경험할 때마다 바이오피드백 방법을 사용해서 사이버멀미 감소 가상환경 (cybersickness alleviating virtual environment, CAVE)을 제시한 후, 그 효과를 관찰하였다. 피부전도도, 말초체온, 말초혈류량, 심박률, 눈 깜박임, 뇌전위의 변수들을 입력으로 하는 인공신경망으로 구성된 실시간 멀미 탐지 시스템과 CAVE-제시 피드백 시스템을 구축하였다. 이 시스템은 생리적 측정치들이 사이버멀미의 출현을 신호할 때마다 피드백 출력으로 좁은 화면과 감소된 운행속도를 일시적으로 제공했다. 36명의 피험자를 대상으로 SSQ (simulator sickness questionnaires)와 자기보고를 이용하여 사이버멀미의 빈도와 심각도를 조사하였다. 모든 피험자는 한달 간격으로 CAVE 조건과 non-CAVE 조건에서 두 번 가상현실을 경험하였다. 사이버멀미의 빈도와 심각도는 non-CAVE 조건보다 CAVE 조건에서 유의미하게 감소하였다. 즉, 전기생리학적 특징들에 기반한 인공신경망에 의해 제공된 좁은 시야와 느린 운행의 가상환경은 사이버멀미 증상들을 의미있게 감소시켰다. 이러한 결과들은 생체신호 피드백 시스템을 이용하여 인간 친화적 가상환경을 구축할 수 있는 가능성을 보인 것이다.

  • PDF

Considerations for increasing denture stability: a case report (의치의 안정성을 증대시키기 위한 고려 요소: 증례보고)

  • Kim, Jiyeon;Kim, Hyeong-Seob;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.311-317
    • /
    • 2012
  • When wearing complete dentures, patients want to function naturally within a physiologically stable range. To do this, recovery of esthetics, biologically stable arrangement and contour, and occlusal contacts with denture stability are necessary. In this case report, a complete denture patient of adverse conditions was presented. To increase stability of the dentures, functional impression was made by border molding using the neutral zone. The dentures were checked for physiological centric relations and stable occlusion. The clinical results showed satisfactory results on function and esthetics.

A Study on the Ship's Performance of T.S. HANBADA(II) - The Evaluation of Boarding Comfort with Vertical Acceleration - (실습선 한바다호의 운항성능에 관한 연구(II) - 상하가속도를 이용한 승선감 평가 -)

  • Jung, Chang-Hyun;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.32 no.5
    • /
    • pp.333-339
    • /
    • 2008
  • When a vessel is underway in a heavy weather, passengers and crew suffer from seasickness caused by ship motions such as pitch, heave or roll, or all combined Sickness induces drowsiness, dizziness, headache, stomachache etc, in extreme conditions, they are met with a serious trouble which is physiologically unrecoverable. It results in weakening of spiritual activities or making errors from decrease of motivation, dropping off skills, poor recognition and poor judgement. In this paper, it was examined the international standards concerning the occurrence of sickness and the execution of works, also evaluated the boarding comfort by conducting several times of questionnaire on cadets boarding on the training ship HANBADA As a result, it was confirmed that the main factor of occurring the sickness was the vertical acceleration and the level was more than 0.2g. Also, it was presented the way how to reduce the sickness by changing the speed and/or course in relation to the encounter period.

A Study on the Use of an Application of Polygraph (거짓말 탐지기 어플리케이션의 활용방안에 관한 연구)

  • Kang, Ye-Seul;Kim, Kwang-Hoon;Kim, Se-Rom;Min, Cho-Rong;Choi, Jae-Sung
    • Annual Conference of KIPS
    • /
    • 2016.10a
    • /
    • pp.878-879
    • /
    • 2016
  • 본 논문에서는 기존의 고비용-고정형 거짓말탐지기의 단점을 극복하기 위하여 거짓말 시 발생되는 인체의 생리적 변화를 측정하기 위한 GSR (Galvanic Skin Response) 센서와 스트레스수치 알고리즘을 활용하여 스마트폰 기반 어플리케이션을 개발 및 그 활용방안을 제안한다. 사용자에게 부착하여 사용자의 생체 피부를 통해 외적자극 또는 심적 흥분/동요 상태에 의한 활동전위 발생 정도를 측정하고 이를 스트레스 지수로 변환할 수 있는 방법을 제시한다. 또한, 사용성 및 저비용성을 보장하기 위하여, 제안하는 거짓말 탐기기능을 스마트폰 어플리케이션화 하였다.

The Efficacy of Biofeedback in Reducing Cybersickness in Virtual Navigation (생체신호 피드백을 적용한 가상 주행환경에서 사이버멀미 감소 효과)

  • 김영윤;김은남;정찬용;고희동;김현택
    • Science of Emotion and Sensibility
    • /
    • v.5 no.2
    • /
    • pp.29-34
    • /
    • 2002
  • Our previous studies investigated that narrow field of view (FOV : 50˚) and slow navigation speed decreased the frequency of occurrence and severity of cybersickness during immersion in the virtual reality (VR). It would cause a significant reduction of cybersickness if it were provided cybersickness alleviating virtual environment (CAVE) using biofeedback method whenever subject underwent physiological agitation. For verifying the hypothesis, we constructed a real-time cybersickness detection and feedback system with artificial neural network whose inputs are electrophysiological parameters of blood pulse volume, skin conductance, eye blink, skin temperature, heart period, and EEG. The system temporary provided narrow FOV and decreased speed of navigation as feedback outputs whenever physiological measures signal the occurrence of cybersickness. We examined the frequency and severity of cybersickness from simulator sickness questionnaires and self-report in 36 subjects. All subjects experienced VR two times in CAVE and non-CAVE condition at one-month intervals. The frequency and severity of cybersickness were significantly reduced in CAVE than non-CAVE condition. Virtual environment of narrow FOV and slow navigation provided by electrophysiological features based artificial neural network caused a significant reduction of cybersickness symptoms. These results showed that efficiency of a cybersickness detection system we developed was relatively high and subjects expressed more comfortable in the virtual navigation environment.

  • PDF

CONSERVATIVE APPROACH ON THE SEVERELY DISPLACED ROOT FRACTURE OF PRIMARY INCISORS : CASE REPORT (심하게 변위된 유전치 치근파절의 보존적 접근)

  • Kim, Jee-Young;Lee, Kwang-Hee;Kim, Dae-Eop;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.571-577
    • /
    • 2008
  • Root fracture of primary teeth is relatively uncommon because the more pliable alveolar bone allows displacement of the tooth. Root fracture of primary teeth is occupied $2{\sim}7%$ in trauma pattern of primary teeth. A horizontal root fracture is classified based on the location of the fracture in relation to the root tip : the apical third, middle third, or cervical third of the root. The prognosis worsens the further cervically the fracture has occurrer. Root fracture of primary teeth should be treated by splinting the incisor to the adjacent normal teeth with a resin-wire splint for $8{\sim}12$ weeks. However, if a portion of the root is abscessed or extremely mobile, it can be extracted, and the remaining root fragment will resorb normally. For coronal third fracture in primary teeth, the coronal third is extracted, leaving the apical portion of the root to resorb normally. These root fracture cases of primary teeth were treated by resin-wire splinting despite extremely mobile coronal fragment. Even though they seems like healing well, They need to be monitored regularly until their successors erupt.

  • PDF

EXPERIMENTAL STUDIES ON THE EFFECT OF RLN ANASTOMOSIS REMOVAL ON PHONATION (반회신경 문합과 후윤상피열근 절제가 발성기능에 미치는 영향에 대한 실험적 연구)

  • 김영모;이영구;이정식;이준열;김광문;김기령;홍원표;최홍식
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.11-12
    • /
    • 1991
  • 편측 성대마비의 음성개선을 위하여 현재까지 알려진 치료방법은 teflon 또는 silicone 주입술, 외과적 성대 내전술, 갑상연골 성형술, 신경재식술, 등이 있으며, 근래까지는 Teflon 또는 Gelform 주입술이 제일 효과적인 방법이라 알려져 있으나, 이는 음의 높낮이 조절능력의 한계가 있고, 신경재식술의 결과 역시 만족스럽지 못한 경우가 많다. 따라서 저자는 발성기능의 생리학적인 측면에서, 보다 효과적인 음성개선의 방법을 찾기 위하여, 사람의 후두와 비교적 유사한 특성을 가진 개를 사용하여 실험을 하였다. 반회신경을 절단하여 편측 성대 마비를 유발한 뒤, 동측의 유일한 외전근인 후윤상피열근을 절제후 절단된 신경을 문합하여, 성대의 외전근 작용의 소실과, 발성시에 주로 작용하는 내전근만의 작용을 유도하여, 공동운동의 차단과, 내전운동의 향상을 기대하였다. 본 실험에 앞서, 임의적으로 신경을 자극시킬 수 있는 신경자극기와, 주위조직으로부터 신경만을 분리하여 자극할 수 있는 전극을 개발하여 사용하였으며, 또한 성대의 발성음을 임의대로 유발시킬 수 있는 생체 내 후두발성 모형(in vivo laryngeal phonation model)을 Moore(1987, 1988)등이 발표한 모형을 토대로 자체 개발하여 사용하였다. 실험은 13마리의 개를, 반회신경 절단군(3 마리), 반회신경 절단 및 후윤상피 열근 절제군(3 마리), 후윤상피열근 절제군(3 마리), 반회신경 문합 및 후윤상피 열근 절제군(4 마리)등으로 나누어 실험하였으며, 3 개월 후, 현수후두경, 후두 내시경, videolaryngoscopy, 신경자극 검사 등으로 성대의 내전운동 및 위치 변화의 관찰, 발성음의 음향분석 및 갑상피열근의 형태학적 변화를 관찰하여 다음과 같은 결과를 얻었다. 1. 반회신경 절단군과 반회 신경 절단 및 후윤상피열근 절제군은, 수술후 3 개월에 성대의 움직임이나 각도의 변화가 없었으며, 음향분석 결과 발성음이 아닌 잡음만이 포착되었다. 즉, 절단된 신경의 문합 없이 후윤상피열근 절제 만으로는 음성개선은 기대할 수 없었다. 2. 후윤상피열근 절제군에서는 수술 후 3 개월에 정상적인 성대의 내전운동이 관찰되었으며, 음향분석상 기본주파수 동요율 및 발성음의 강도는 약간의 증가를 보였다. 즉, 반회신경이 절단되지 않은 상태에서 후윤상피 열근 만을 절제하면, 발성음의 변화는 거의 없었다. 3. 반회신경을 절단후 문합하고 후윤상피열근을 절제한군 에서는 수술후 3 개월에, 성대의 정상적인 내전운동을 보였고, 음향분석상 수술직후에는 잡음만이 포착되었으나, 3 개월 후에는 잡음이 아닌 발성음을 들을 수 있었으며, 이 발성음의 기본주파수 및 강도는 수술전보다 감소되어 있었으나, 기본주파수 동요율은 증가되어 있었다. 즉 이 술식으로 인한 뚜렷한 발성음의 향상이 있었다. 이상의 결과로 미루어, 편측 신경 절단으로 인한 성대마비시, 절단된 신경을 봉합하고 성대의 유일한 외전근인 후윤상피열근을 절제하면, 공동운동의 차단과, 내향운동의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다.

  • PDF