• Title/Summary/Keyword: 샘플링 주기

Search Result 142, Processing Time 0.023 seconds

Data Acquisition of Time Series from Stationary Ergodic Random Process Spectrums (정상 에르고드성을 가지는 확률과정 스펙트럼에 대한 합리적 시계열 데이터 확보)

  • Park, Jun-Bum;Kim, Kyung-Su;Choung, Joon-Mo;Kim, Jae-Woo;Yoo, Chang-Hyuk;Ha, Yeong-Su
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.120-126
    • /
    • 2011
  • The fatigue damages in structural details of offshore plants can be accumulated due to various environmental loadings such as swell, wave, wind and current. It is known that load histories acting on mooring and riser systems show stationary and ergodic bimodal wide-banded process. This paper provides refined approach to obtain time signals representing stress range histories from wide-banded bimodal spectrum which consists of ideally narrow-banded and fully separated two spectrums. Variations of the probabilistic characteristics for time signals according to frequency and sampling time increments are compared with the reference data to be the probabilistic characteristics such as zero-crossing period, peak period, and irregularity factor obtained from an assumed ideal spectrum. It is proved that the sampling time increment more affects on the probabilistic characteristics than frequency increment. The fatigue damages according to the frequency and sampling time increments are also compared with the ones with minimum increment condition which are thought to be exact fatigue damage. It is concluded that the maximum sampling time increment to obtain reliable time signals should be determined that ratio of applied maximum sampling time increment and minimum period is less than approximately 0.08.

An Improved MPPT Converter with Current Compensation Method for Small Scaled PV-Applications (소규모 태양광 발전시스템을 위한 전류보상기법을 갖는 향상된 MPP 추적 컨버터)

  • 이동윤;노형주;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.143-150
    • /
    • 2003
  • An improved MPPT converter with current compensation method for small-scaled PV-applications is presented in this paper. The proposed method implements maximum power point tracking (MPPT) by variable reference current which is continuously changed during one sampling period. Therefore, the Power transferred to the load is increased above 9% by the proposed MPPT converter with current compensation method. As a result, the utilization efficiency of Photovoltaic (PV)-panel can be increased. In addition, as it doesn't use digital signal processor (DSP), this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV-applications. The concept and control principles of the proposed Un moth()d are explained in detail and its validity of the proposed method is verified through several simulated results.

A Study on Frequency Hopping Signal Detection Using a Polyphase DFT Filterbank (다상 DFT 필터뱅크를 이용한 도약신호 검출에 관한 연구)

  • Kwon, Jeong-A;Lee, Cho-Ho;Jeong, Eui-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.789-796
    • /
    • 2013
  • It is known that the detection of hopping signals without any information about hopping duration and hopping frequency is rather difficult. This paper considers the blind detection of hopping signal's information such as hopping duration and hopping frequency from the sampled wideband signals. In order to find hopping information from the wideband signals, multiple narrow-band filters are required in general, which leads to huge implementation complexity. Instead, this paper employs the polyphase DFT(discrete Fourier transform) filterbank to reduce the implementation complexity. This paper propose hopping signal detection algorithm from the polyphase DFT filterbank output. Specifically, based on the binary image processing, the proposed algorithm is developed to decrease the memory size and H/W complexity. The performance of the proposed algorithm is evaluated through the computer simulation and FPGA (field programmable gate array) implementation.

Performance Analysis of DMF Acquisition System in Frequency-Selective Rayleigh Fading Channel (주파수 선택적 레일리 페이딩 채널에서의 DMF 초기동기 장치의 성능분석)

  • 김성철;이연우;조춘근;박형근;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1351-1360
    • /
    • 1999
  • In frequency selective channels, conventional PN code acquisition schemes are not ideal candidates. This is because they are primarily designed for the AWGN channel. In this paper, a direct-sequence spread-spectrum(DSSS) PN code acquisition system based on digital matched filtering (DMF) with automatic threshold control(ATC) algorithm is presented and analyzed with regards to probability of detection and probability of false alarm. These two important probabilities, the probability of detection ($P_D$) and the probability of false alarm ($P_{FA}$) are derived and analyzed in considering Doppler shift, sampling rate, mean acquisition time, and PN chip rate in frequency selective Rayleigh fading channel when using serial-search method as detection technique. From computer simulation results of a DMF acquisition system model, it is shown that the performance of the acquisition system using ATC algorithm is better than that of constant threshold system.

  • PDF

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Wireless Electrocardiogram Monitoring System for Small Animals Based on IEEE 802.15.4 (IEEE 802.15.4에 기초한 작은 동물을 위한 무선 심전도 감시 시스템)

  • Kim, Dong-Sik;Jin, Ju-Youn;Jo, Mi-Young;Nam, Do-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.36-43
    • /
    • 2009
  • Electrocardiogram (ECG) is a graphical record of the voltages generated during the heart beats, and is very useful in observing the status of the heart of the human or animals. In this paper, an ECG monitoring system is developed for the small animals, such as the rat. This system is very useful in monitoring the side effect of drugs. Since small animals have faster heart rate than the human case, the monitoring system has a faster sampling frequency and processing speed. Furthermore, for a realtime monitoring of the small moving animals, the system is composed of a small wireless ECG module, which is based on the IEEE 802.121.4 wireless physical layer. The developed wireless ECG system can successfully monitor the ECG of small animals, such as the rat.

Experimental Study on Structure Characteristics of Particulate Matter emitted from Ship at Various Sampling Conditions (다양한 샘플링 조건에 따른 선박 배기가스 내 입자상물질의 구조 특성에 관한 실험 연구)

  • Lee, Won-Ju;Jang, Se-Hyun;Kim, Sung-Yoon;Kang, Mu-Kyoung;Chun, Kang-Woo;Cho, Kwon-Hae;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.547-553
    • /
    • 2016
  • Black carbon (BC) contained in particulate matter (PM) originating from the exhaust gases of ships' diesel engines has been receiving great attention as a cause of glacial melting and warming in the polar regions. In this study, we took samples from various locations of PM emitted from the training ship (T/S) HANBADA's main engine, in cooperation with the Korea Maritime and Ocean University. We analyzed the structure and characteristics of these samples using high-resolution transmission electron microscopy (HR-TEM) and applied our findings as fundamental research for developing PM reduction technology. We also employed our results to determine appropriate preemptive action to meet upcoming PM/BC regulations. In addition, we confirmed the emission trend of pollutants from exhaust gases under various engine operating conditions using an exhaust gas analyzer. Results obtained from the analysis of HR-TEM images showed that the structure of the PM is chain-like wispy agglomerates consisting of a number of individual spherical particles. As the sampling location was moved away from the turbo charger (T/C) towards the funnel, more condensates were observed at a low temperature and the molecular structure of the PM lost its characteristic BC structure as an amorphous structure gradually appeared. Furthermore, through the analysis of exhaust gases, we predicted a decrease in PM concentration in the exhaust stream as engine rpm increase.

Spectral Characteristics of Sea Surface Height in the East Sea from Topex/Poseidon Altimeter Data (Topex/Poseidon에서 관측된 동해 해수면의 주기특성 연구)

  • 황종선;민경덕;이준우;원중선;김정우
    • Economic and Environmental Geology
    • /
    • v.34 no.4
    • /
    • pp.375-383
    • /
    • 2001
  • We extracted sea surface heights(SSH) from the TopexJPoseidon(T/P) radar altimeter data to compare with fhe SSH estimated from in-situ lide gauges(T/G) at Ulleungdo, Pohang, and SockcholMucko sites. Selection criteria such as wet/dry troposphere, ionosphere, and ocean tide were used to estimate accurate SSH. For time series analysis, the one-hour interval tide gauge SSHs were resampled al lO-day interval of the satellite SSHs. The ocean tide model applied in the altimeter data processing showed periodic aliasings of 175.5 day, 87.8 day, 62J day, 58.5 day, 49.5 day and 46.0 day, and, hence, the ZOO-day filtering was applied to reduce these spectral noises. Wavenumber correlation analysis was also applied to extract common components between the two SSHs, resulting in enhancing the correlation coefficient(CC) dramatically. The original CCs between the satenite and tide gauge SSHs are 0.46. 0.26, and 0.]5, respectively. Ulleungdo shows the largest cc bec;luase the site is far from the coast resulting in the minimun error in the satellite observations. The CCs were then increased to 0.59, 030, and 0.30, respectively, after 200.day filtering, and to 0.69, 0.63. and 0.59 after removing inversely correlative components using wavenumber correlation analysis. The CCs were greatly increased by 87, 227, and 460% when the wavenumber correlation analysis was followed by 2oo-day filtering, resulting in the final CCs of 0.86, 0.85, 0.84, respectively. It was found that the best SSHs were estimated when the two methods were applied to the original data. The low-pass filtered TIP SSHs were found to be well correlated with the TIG SSHs from tide gauges, and the best correlation results were found when we applied both low-pass filtering and spectral correlation analysis to the original SSHs.

  • PDF

A small ocean bottom electromagnetometer and ocean bottom electrometer system with an arm-folding mechanism (Technical Report) (팔-접힘 구조를 가지는 소규모 OBEM과 OBE시스템 (기술보고서))

  • Kasaya, Takafumi;Goto, Tada-nori
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Natural magnetic fields are attenuated by electrically conductive water. For that reason, marine magnetotelluric surveys have collected data at long periods (1000-100 000 s). The mantle structure has been the main target of seafloor magnetotelluric measurements. To ascertain crustal structure, however, electromagnetic data at shorter periods are important, e.g. in investigations of megathrust earthquake zones, or in natural resource surveys. To investigate of the former, for example, electromagnetic data for periods of less than 1000 s are necessary. Because no suitable ocean bottom electromagnetometer (OBEM) has been available, we have developed a small OBEM and ocean bottom electrometer (OBE) system with a high sample rate, which has an arm-folding mechanism to facilitate assembly and recovering operations. For magnetic observation, we used a fluxgate sensor. Field observations were undertaken to evaluate the field performance of our instruments. All instruments were recovered and their electromagnetic data were obtained. Results of the first experiment show that our system functioned well throughout operations and observations. Results of other field experiments off Tottori support the claim that the electromagnetic data obtained using the new OBEM and OBE system are of sufficient quality for the survey target. These results suggest that this device removes all instrumental obstacles to measurement of electromagnetic fields on the seafloor.

A Robust Recovery Method of Reference Clock against Random Delay Jitter for Satellite Multimedia System (위성 멀티미디어 시스템을 위한 랜덤 지연지터에 강인한 기준 클럭 복원)

  • Kim Won-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.2
    • /
    • pp.95-99
    • /
    • 2005
  • This paper presents an accurate recovery method of the reference clock which is needed for network synchronization in two-way satellite multimedia systems compliant with DVB-RCS specification and which use closed loop method for burst synchronization. In these systems, the remote station transmits TDMA burst via return link. For burst synchronization, it obtains reference clock from program clock reference (PCR) defined by MPEG-2 system specification. The PCR is generated periodically at the hub system by sampling system clock which runs at 27MHz $\pm$ 30ppm. Since the reference clock is recovered by means of digital PLL(DPLL) using imprecise PCR values due to variable random jitter, the recovered clock frequency of remote station doesn't exactly match reference clock of hub station. We propose a robust recovery method of reference clock against random delay jitter The simulation results show that the recovery error is remarkably decreased from 5 clocks to 1 clock of 27MHz relative to the general DPLL recovery method.

  • PDF