• Title/Summary/Keyword: 색견본

Search Result 6, Processing Time 0.03 seconds

Evaluation of color matching ability according to the color temperature and the experience of practitioner (색 온도 및 술자의 숙련도에 따른 비색 능력 평가 원저)

  • Kim, Ji-Hyun;Kim, Sun-Jai;Lee, Keun-Woo;Shim, June-Sung;Yoon, Joonho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.299-304
    • /
    • 2012
  • Purpose: The aim of this study is to investigate the effect of different experience level and different light source on shade selection ability comparing prosthodontist group and dental student group under 4,000 K and 5,500 K light. Materials and methods: After color difference of Vitapan 3D-master shade guides was measured, 3 sets of 5 shade tabs were selected with similar value but have different chroma (set a, b, c). Also 3 sets of 5 shade tabs were selected with similar chroma but have different values (set d, e, f). Under 4,000 K and 5,500 K light sources, ten prosthodontists and ten dental students were allowed to match in one set of 5 tabs the same shade tab with the tab which was originally selected in the other set of 5 tabs. Color differences of original tab and matched tab were measured by spectrophotometer and the shade selection ability was evaluated with those data. Evaluation of color difference value was performed in regard to different light conditions and different level of experience, followed by t-test with 95% confidence interval. Results: Color difference values under 4,000 K and 5,500 K light source were $1.62{\pm}2.0$, and $1.33{\pm}1.7$ respectively. In addition, color difference values of prosthodontist group and dental student group were $1.34{\pm}1.7$, and $1.61{\pm}2.0$ respectively. Difference of shade selection ability was not found under either different light sources (P=.398), or different experience level (P=.221). Conclusion: Level of experience did not affect on the shade selection ability when prosthodontists and dental students matched the shades with the same shade tab under the same light source.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

Effect of Application of ZirLiner® and Blasting Treatments on Shear Bond Strength of Zirconia-Veneered Porcelain Interface (지르코니아-전장도재 계면의 전단결합강도에 대한 ZirLiner® 적용과 분사처리의 영향에 관한 연구)

  • Shin, Young-Ho;Lee, Yu-Na;Lee, Hae-Hyoung;Dong, Jin-Keun;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.113-127
    • /
    • 2008
  • The purpose of this study was to evaluate effect of application of $ZirLiner^{(R)}$ and blasting treatments on shear bond strength of zirconia-veneered porcelain interface. 60 uncolored zirconia plates and 30 colored zirconia plates were fabricated and divided into nine groups of 10 according to blasting treatment such as as-ground, glass blasting and alumina blasting and zirliner application. Veneering porcelains were built up over the center of the treated zirconia ceramic surface using jig and fired according to the manufacturers' instructions. Each specimen was completely embedded in acrylic resin. The specimens were placed in a mounting jig and subjected to shear force by a universal testing machine. Load was applied at a crosshead speed of 0.5㎜/min until failure. Average shear strengths were analyzed with two-way analysis of variance and one-way analysis of variance and the Duncan's post-hoc test. The fracture surfaces of the failed specimens were examined by SEM. The obtained results were as follows: 1. Depending on surface treatment by blasting, the degree of roughness is revealed in the order of Glass-blasted, As-ground, and Alumnia-blasted. The roughness average of uncolored and colored zirconia ceramic were not significantly different from blasting treatments. 2. In uncolored zirconia ceramic, the shear bond strength were not significantly different from blasting treatments. However, the shear bond strength were significantly different from Zirliner application. 3. Used ZirLiner, mean shear bond strength of colored zirconia was lower than uncolored zirconia. Especially, mean shear bond strength of colored zirconia was quite low with alumina-blasting treatment. 4. SEM analysis showed that veneered porcelain failed in zirconia ceramic interface and there was no cohesive failure.

Features of the Costumes of Officials in the King Jeongjo Period Seojangdaeyajodo (정조대 <서장대야조도(西將臺夜操圖)>의 관직자 복식 고증)

  • LEE, Eunjoo;KIM, Youngsun;LEE, Kyunghee
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.78-97
    • /
    • 2021
  • Seojangdaeyajodo is a drawing of military night training on February 12th (lunar leap month), 1795. Focusing on the Seojangdaeyajodo, the characteristics and of the costumes worn by various types of officials were examined. There were 34 officials located near King Jeongjo in and around Seojangdae, with 27 Dangsanggwan and 7 Danghagwan. They wore three types of costumes, including armor, yungbok, and military uniforms. All of the twelve armor wearers and the five officials wearing yungbok were dangsanggwan, and the military uniform wearers included eleven dangsanggwan and six danghagwan. For the shape of the armor, the armor relics of General Yeoban, suitable for riding horses, and the armor painting of Muyedobotongji were referenced, and the composition of the armor was based on practicality. The armor consists of a helmet, a suit of armor, a neck guard, armpit guards, arm guards, and a crotch guard. The color of the armor was red and green, which are the most frequently used colors in Seojangdaeyajodo. The composition of yungbok was jurip, navy cheollik, red gwangdahoe, socks made of leather, and suhwaja. The composition of the military uniform was a lined jeolrip, dongdari, jeonbok, yodae, jeondae, and suhwaja. There were differences in the fabrics used in dangsanggwan and danghagwan military uniforms. Dangsanggwan used fabric with depictions of clouds and jewels, and danghagwan used unpatterned fabric. Moreover, jade, gold, and silver were used for detailed ornamental materials in dangsanggwan. The weapons included bows and a bow case, a sword, a rattan stick, wrist straps, and a ggakji. In the records of the King Jeongjo period, various colored heopsu were mentioned; the colors of the dongdari and jeonbok of dangsanggwan and danghagwan were referenced in various colors. It was presented as an illustration of costumes that could be used to produce objects accurately reflecting the above historical results. The basic principle of the illustration was to present the modeling standards for 3D content production. Samples of form, color, and material of the corresponding times and statuses were presented. The front, the side, and the back of each costume and its accessories were presented, and the colors were presented in RGB and CMYK.