• Title/Summary/Keyword: 상악 대구치의 원심이동

Search Result 25, Processing Time 0.044 seconds

The frog appliance for upper molar distalization: a case report (Frog appliance를 이용한 상악 대구치의 원심 이동: 증례 보고)

  • Bayram, Mehmet;Nor, Metin;Kilkis, Dogan
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.50-60
    • /
    • 2010
  • The purpose of this article was to evaluate the effects of a new upper molar distalization system, the Frog Appliance, on dentofacial structures in a Class II, division 1 patient. An 11-year-old girl was referred to our clinic for orthodontic treatment. She had a mild skeletal Class II malocclusion with Class II molar and canine relationship on both sides. The treatment plan included distalization of the upper first molars bilaterally followed by full fixed appliance therapy. For the upper molar distalization, a new system, the Frog Appliance, was constructed and applied. Lateral cephalometric radiographs were used to evaluate the treatment results. Distalization of the upper first molars was achieved in four months successfully, and Class I molar relationship was obtained. Total treatment time was 16 months. According to the results of the cephalometric evaluation, a nearly bodily distal molar movement with a slight anchorage loss was attained. In conclusion, the Frog Appliance was found to be a simple, ef ective, non-invasive, and compliance-free intraoral distalization appliance for achieving bilateral molar distalization.

MAXILLARY MOLAR DISTALIZATION WITH A PENDULUM APPLIANCE (Pendulum 장치를 이용한 상악 대구치의 원심이동 증례)

  • Lee, H.J.;Kim, Y.J.;Kim, J.W.;Jang, K.T.;Lee, S.H.;Kim, C.C.;Hahn, S.H.
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.523-531
    • /
    • 2008
  • Maxillary molar distalization is a treatment approach for patients with Class II malocclusions who do not require extractions and mesial movements of mandibular molars. The pendulum appliance is effective for distalization of the maxillary molars and independent of patient cooperation. This appliance can stabilize the maxillary premolars and use the palatal rugae area as an additional anchorage. However, caution is needed to control collateral effects, including increase of lower facial height, incisor protrusion and damage to the rugae area. This article reports the cases in which maxillary molar distalization achieved by pendulum appliance resolves the space problems and corrects the molar relationships.

  • PDF

THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE (Pendulum 장치의 상악대구치의 원심이동에 대한 효과)

  • Lee, Chang-Seop;Kim, Jae-Gwang;Kang, Dug-Il;Song, Kwang-Chul;Jung, Hyun-Ku;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.488-495
    • /
    • 2001
  • Treatment of class II malocclusions require distalization of maxillary molars into class I relationship. Intraarch distal molar movement techniques have recently assumed an important role in young patients. In this study, the dental and skeletal effects of the pendulum appliance were evaluated by means of cephalometric radiographs. The samples were consisted of 19 patients: 11 females and 8 males, mean age $11.68{\pm}1.52$ years. Measurements were obtained from cephalometric prior to and the day of removal of the pendulum appliance. Treatment changes were analyzed. The following results were obtain. 1. The pendulum appliance produced $2.94{\pm}1.54mm$ distal molar movement with a mean intrusion of $1.17{\pm}0.97mm$, mean period $18.13{\pm}7.95$ weeks. 2. The anchor tooth was $1.34{\pm}1.40mm$ forward movement and $0.48{\pm}0.99mm$ extrusion, and labial tilting of incisors. 3. The angle between palatal plane and mandibular plane increased significantly. 4. There was no significant difference in according to 2nd molar position. 5. Total movement was consisted of 74% distal movement of 1st molar and 26% forward movement of the anchor tooth.

  • PDF

MAXILLARY MOLAR DISTALIZATION AND PREMOLAR ALIGNMENT WITH A JONES JIG APPLIANCE: CASE REPORTS (Jones jig 장치를 이용한 상악 대구치 원심이동 및 소구치 배열의 증례 보고)

  • Jeon, Eun-Kyung;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.497-504
    • /
    • 2010
  • The treatment of Class II non-extraction cases, especially when premolar space is lost due to premature loss of the deciduous molars, usually requires distal movement of the maxillary molars. The Jones jig appliance is a non-compliant intraoral appliance and is effective for the distalization of the maxillary molars. It has unfavorable side-effects, however, so caution is needed to adjust the appliance and select appropriate cases. We reported four cases in which maxillary molar distalizations were concomitant with the alignment of palatally erupted premolars.

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

MAXILLARY MOLAR DISTALIZATION WITH THE BONE-SUPPORTED PENDULUM (Bone-supported pendulum을 이용한 상악대구치 원심이동)

  • Jang, Yong-Gul;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.464-474
    • /
    • 2009
  • To distalize the maxillary molars, the traditional techniques such as extra-oral traction, Wilson distalizing arches, removable spring appliances and Schwarz plate-type appliances have been used. But, these need considerable patient cooperation. For minimal patient compliance, many practitioners use the pendulum appliances. Several clinical studies demonstrated pendulum is effective molar distalization appliance in the growing patient(using the premolars and the palate as anchorage). But unfortunately, maxillary anterior teeth also shift mesially as the molar moves distally. As a result anchorage loss is occurred. To overcome these disadvantages, we used bone-supported pendulum, combined the conventional pendulum with Skeletal Anchorage System(SAS). The miniscrew was implanted in the anterior paramedian region of the median palatal suture, which has comparatively sufficient bone thickness and is low risk to damage on the dental follicles. We report three cases, using bone-supported pendulum for the maxillary molar distalization in children. After treatment, we find out anchorage stability, minimal unfavorable anterior tooth movement and sufficient molar distalization.

  • PDF

TREATMENT OF ECTOPICALLY ERUPTED MAXILLARY FIRST PERMANENT MOLARS (이소맹출 한 상악 제1대구치의 맹출 유도)

  • Yun, Hyo-Jin;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.519-525
    • /
    • 2010
  • Ectopic eruption means the eruption of the tooth in an abnormal position due to multiple factors, which found most frequently in maxillary fist permanent molars, mandibular lateral incisors and maxillary permanent canines. Ectopic eruption of the maxillary first permanent molar occurs when the molar erupts with a more mesial angulation than normal, and locks itself in an atypical resorption on the distobuccal root of the second primary molar. The maxillary first permanent molar plays important roles for mastication and occlusion, so ectopically erupted maxillary first permanent molars should be relocated into proper position. Treatment options are separation by insertion of the brass wire or elastic rings, preparation of distal aspect of the maxillary second primary molar, using fixed or removable appliance with finger spring, and placement of space maintainer or space regainer after extraction of the maxillary second primary molar. We report three cases treated of ectopically erupted maxillary first permanent molar by re-setting of stainless steel crowns, placement of brass wire and using active plate. We could find out distal movement of maxillary first permanent molars into proper position and normal occlusion.

3-dimensional finite element analysis of maxillary molar distalization using R-jig with TADs (TADs와 R-jig를 이용한 상악 구치 원심 이동에 관한 3차원 유한요소 분석)

  • Tark, Myung-Hyun;Lee, Keunyoung;Cho, Jin-Woo;Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.265-277
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the differences of displacement pattern depending on type of sliding jig and application method during maxillary molar distalization with temporary anchorage devices (TADs). Materials and Methods: Maxilla with normal tooth size and arch shape was selected to create a 3-dimensional finite element model, which included the bracket, orthodontic main archwire, removable sliding jig (R-jig). The orthodontic mini-implant anchorage was set 8 mm superiorly from main archwire, buccally between the second premolar and first molar. The base experimental design was Condition 1, which was composed $0.019{\times}0.025$ inch stainless steel (SS) of wire size of R-jig, 200 gm force, un-tied state. And the other designs varied to wire size of R-jig, magnitude of force. The results are as follows. Results: As the wire size of R-jig was increased, the deformation of R-jig was decreased. However, the displacement of second molar wasn't different each other. As the force to second molar was increased, the more displacement of second molar was observed, and the more distal tipping movement, vetical displacement was observed. Conclusion: R-jig can get distal teeth movement in orthodontic treatment without side effects.