• Title/Summary/Keyword: 상수도 시설물

Search Result 113, Processing Time 0.023 seconds

Basic Study on Logical Model Design of Underground Facilities for Waterworks (상수도 지하시설물의 논리적 모델 설계에 관한 기초 연구)

  • Jeong, Da Woon;Yu, Seon Cheol;Min, Kyung Ju;Lee, Ji Yeon;Ahn, Jong Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.533-542
    • /
    • 2020
  • This study proposes the logical data model design of a spatial data model that complies with international standards for the waterworks of underground facilities. We conduct a preliminary study related to underground spatial data standards and data models, and review the status of the existing systems. Then, we defined the conceptual design direction of underground spatial data model based on the problems and issues. Next, we defined the terminology, classification, semantic relationships of waterworks. Next, for the conceptual design of the underground spatial data model, we defined the naming criteria for all data according to the waterworks classification. In addition, a logical model is drawn and described using UML (Unified Modeling Language) diagrams. Based on the results, it is expected that the accuracy related to underground facilities data will be improved.

Improving the Detection of the Water Mains Underground Facilities (상수도 지하시설물 탐사 개선에 관한 연구)

  • Kim, Jae-Myeong;Lee, Byung-Woon;Choi, Yun-Soo;Yoon, Ha-Su
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.23-32
    • /
    • 2010
  • Water mains underground facilities are essential components to make up urban infrastructure. In order to manage these water mains underground facilities systematically and scientifically, GIS (Geographic Information System) had been constructed. For the sake of construction of GIS for water mains underground facilities, an exact underground detection and the construction of DB (Data Base) for buried water mains underground facilities should be preceded. In this study, in order to find out the ways to improve exact detection rate of data, the statistical analysis for the causes of detection raw degradation was done, and standardization methods of detection through a case study were suggested, When water mains underground facilities were measured, the detection of non-metallic water pipes was not carried out. The reason was that the results of detection was uncertain and detection was difficult because the assessment of public measurements was vulnerable. Moreover, due to the absence of standardized operating regulations for detection, systematic surveys weren't conducted. In this study, methods to standardize works over the detection of water mains underground facilities were presented so that we can improve the detection rate when we are doing that. As the proposals to improve detection rate, effective performance assessment over non-metallic pipes were presented, and related issues to supplement work regulations of public survey were described systematically.

A Study on the Priority Order Evaluation of the Water Supply Monitoring Technology Development for the Intelligent Underground Facility Management (지능형 지하시설물관리를 위한 상수도 모니터링 기술개발의 우선순위 평가에 관한 연구)

  • Kim, Jung-Hoon;Yi, Mi-Sook;Han, Jay-Il
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.263-278
    • /
    • 2008
  • Nowaday, local governments have planned to manage intelligent underground facilities through the u-City project. But, the intelligent underground facilities are in need of the progressive approach because of the required huge financial resources. Therefore, the objectives of this research are (1) to prioritize the monitoring items of sensing technology developments, (2) to study technological feasibilities, and (3) to discover the killer application which expands ripple effects on economy. To achieve these objectives, final monitoring items were derived from the business analysis of the water supply, the local government survey, the hearing expert opinions and so on. The priority order of final monitoring items were technology developments of (1) the flowmeter flux, (2) the water leakage/crack, (3) the pressure of water supply pipes, and (4) the flux of filtration plants. The research significance is obtained from the derivation and the evaluation of the priority order and the actual demand for the water supply facility management. And, the research results will contribute to the strategic planning for the underground facility intelligence.

  • PDF

Development of an Application System for Efficient Management of Underground Water Supply Facility - Pilot Study in Chonju City - (상수도 지하시설물의 효율적 관리를 위한 응용시스템 개발 -전주시를 대상으로-)

  • 오권호;진철하;이근상;정승현;조기성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.111-120
    • /
    • 2000
  • Water, waste, electric and gas facilities are urban based facilities that needed in our life and are often located in underground. Therefore, underground facilities are more difficult to manage efficiently than ground facilities. It is needed to carry out survey/probe into underground facilities and to build database in order to prevent city-misfortunes being occurred because of negligent management and in order to minimize budget-waste and a traffic jam according to repetition of road excavation constructions. Also, the development of application system is required to manage efficiently underground facility. Chonju city has launched underground water supply facility computerizing project as a part of National Geographic Information System project until December 1998 and executed survey/probe into 402.89 km water supply that is 80 mm up inside central town area 39.6 $km^2$. Also, chonju city built database into 537 km water supply that is 80 mm below based on water supply card without other survey/probe works. Also, existing work process each department is changed into GIS applied work process and underground water supply facility management system is developed by its work process basis. Water supply underground facility management system that is developed is composed of sub-system like base-map management, water supply inspect, water supply management and water supply inquiry, construction work management, administration management and map management. This research presents the procedure and method of underground water supply facility survey/probe and problem being occurred during survey/probe procedure and also show the functions of each sub-systems composing underground water supply facility management system.

  • PDF

A study on Improving the Accuracy Detection of the Water Mains Underground Facilities (상수도 지하시설물 탐사정확도 제고방안 -서울시 상수도 GIS사례를 중심으로-)

  • Lee, Byung-Woon;Choi, Yun-Soo;Cha, Seong-Yeol;Yoon, Ha-Su;Song, Hyun-Kun
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.09a
    • /
    • pp.344-345
    • /
    • 2010
  • 도시 인프라를 구성하는 필수적 요소인 상수도 시설물을 체계적이고 과학적으로 관리하고자 상수도 GIS를 구축하였으나 그 동안 구축된 상수도 지하시설물에 대한 위치정확도가 높지 않아 정확도 개선사업이 필요하게 되었다. 이에, 본 연구에서는 통계적인 자료를 통하여 탐사율 저하원인을 분석하고 서울시 상수도 GIS의 사례를 조사함으로써 탐사에 대한 표준화 방안과 함께 탐사율 제고를 위한 정책 제안사항을 제시하였다. 이로써, 체계적인 탐사를 통하여 탐사율을 향상시킬 수 있을 것으로 판단된다.

  • PDF

The Utility of Phased Array Ultrasonic Testing(PAUT) for Corrosion Evaluation of Water Supply Steel Pipes (상수도 강관의 부식 평가에 대한 위상배열초음파(PAUT)의 활용)

  • Sang Hyeok Son;Chang Gun Shin;Jea Yeon Jeong;Jong Sik Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.490-490
    • /
    • 2023
  • 위상배열초음파검사(PAUT)는 기존 초음파검사에서 획득할 수 있었던 A-scan의 결과와 달리, 관로 내부로 진입하지 않고도 부식에 의한 강관 손상 정도를 정량적인 시각적 데이터로 파악할 수 있는 검사 기술이다. 관내부 직접조사가 가능한 상수도 강관을 대상으로 직접조사와 PAUT를 비교한 결과, PAUT는 높은 정확도와 신뢰성을 보여주었다. 또한, 강관 내부의 부식검사에서는 PAUT를 적용함으로써 관체의 부식 면적, 부식 최대 깊이, 부식 위치를 넓은 범위에서 신뢰성 높은 검사 및 결과 도출이 가능하였다. 이러한 결과는 PAUT 기술이 강재 구조물의 다양한 부식 문제를 신속하게 파악하고 해결하는 데 기여할 수 있음을 의미한다. 따라서, 본 검사 기법은 상수도 관로의 강재 진단 및 점검에 있어 높은 신뢰성 및 효율성을 보여 주는 진단기법으로써 다양한 강재 시설물의 평가에 활용성이 클 것으로 판단된다. 이에 따라 PAUT는 상수도 시설물뿐만 아니라 다양한 시설물에서도 높은 활용 가능성을 가질 것으로 예상된다.

  • PDF

Context-Awareness Scenario for Ubiquitous Environment : Case of Water Supply (유비쿼터스 환경기반의 상황인식 시나리오 연구 - 상수도 사례를 중심으로 -)

  • Jeong, Jin-Seok;Lee, Yong-Joo;Byun, In-Sun;Kim, Tae-Hoon;Song, Yong-Hak
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.2
    • /
    • pp.47-53
    • /
    • 2009
  • Recently, context-awareness computing becomes prerequisite to pervasive computing, called ubiquitous paradigm. Especially, it plays much of roll as a part of the ubiquitous infrastructures, one of three ubiquitous city components. This paper proposes the optimized procedures to deal with the various hypothetical water-leaking situations in the water supply systems. These procedures suggested in this paper will be employed to develop the context-awareness modules or models for urban infrastructure maintenance in the future works.

  • PDF

Development of Underground Conduits Eco-Monitoring System (지하공간 환경 모니터링 시스템 개발 및 시험)

  • Park, Jungl-Kwon;Han, Jin-Woo;Kang, Wang-Kyu;Woo, Byong-Soo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.40-44
    • /
    • 2009
  • 지하구는 도시의 신경망이라 할 수 있는 통신, 전력, 상수도, 난방, 쓰레기 처리시설 등 도시 운용/관리를 위한 주요시설물을 안전하게 수용하고, 유지 관리하기 위한 시설로 IT기술을 이용하여 수용된 시설을 효과적으로 유지/관리하고, 재난으로부터 안전하게 보호함과 동시에 최소의 비용과 에너지로 수용된 시설물을 유지관리하기 위한 연구가 많이 진행되고 있다. 따라서 본 논문에서는 지하구(공동구, 통신구, 전력구)의 운용 및 유지관리와 지하구에서 발생될 수 있는 각종 재난에 대응하기 위한 지하구 운용 및 유지관리에 대해 알아보고, 지하구 내부에 수용된 시설물을 효과적으로 유지관리하고 재난에 신속히 대응하기 위한 지하구 환경모니터링 시스템에 대해 기술 하고자 한다. 지하구 환경모니터링 시스템은 지하구 내부에는 전력, 상수도, 통신, 난방 등 다양한 시설물이 수용되어 있으며, 이러한 시설물의 부식, 고장 등으로부터 보호하기 위해 지하구내부의 환기시스템의 송풍기와 지하수와 기상재해로 인한 지하구 및 수용시설물의 침수를 막기 위한 양수펌프에 대해 실시간 상태모니터링 통해 송풍기 및 펌프의 고장여부를 판단하여 관리자에게 알림으로써 관리자가 신속하게 대응 할 수 있도록 하였다. 송풍기의 제어는 지하의 내부와 외부에 설치된 온/습도 센서를 통해 지하구 내부환경을 최적으로 유지할 수 있도록 함으로써 쾌적한 지하 내부환경 유지하고, 급/배기가 필요할 경우에만 송풍기를 가동함으로써 에너지를 절약 할 수 있으며, 화재, 침수 등에 대한 재난시 환풍기의 급/배기, 정지 등을 신속하게 제어할 수 있도록 하였다. 또한 지하구내부에서 발생된 재난을 유/무선을 이용하여 신속하게 지하구 주변의 장치(U-Pole 또는 통합컨트롤러)를 통해 경보를 전파함으로써 주변 시민들이 안전하게 대피할 수 있도록 하였다. 그리고 지하구 환경모니터링 시스템을 검증하기 위해 실제 지하구 및 실험실에 시스템 및 Test Board을 설치하여 운용시험을 실시 하였다.

  • PDF

A Study on the Development Strategy for Integrated Urban Spatial Information Management Platform (지능형 도시공간정보 통합 플랫폼 개발 전략 연구)

  • Hong, Sang-Ki
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.119-126
    • /
    • 2008
  • 도시공간정보 통합플랫폼은 도시의 체계적이고 과학적인 관리, 특히 지상 및 지하시설물 관리에 필요한 센서 및 미들웨어 기술, 유무선 네트워크, GIS-USN 연계 등의 요소기술이 집적된 지능형 도시운영 기반환경으로 정의된다. 도시공간정보 통합플랫폼은 상수도, 하수도, 가스, 난방, 송유, 전력, 통신의 7대 지하시설물과 교량, 육교, 터널 등 도시 지상시설물 등 도로기반시설물 관리를 지능화 할 수 있는 기반 환경을 제공하는 역할을 수행해야 한다. 본 연구에서는 지능형 도시공간정보 통합플랫폼 개발을 위해 플랫폼의 비전을 설정하고 개방형 분산처리 레퍼런스 모델(RM-ODP, Reference Model for Open Distributed Processing)의 적용을 통해 개발전략을 도출하였다.

  • PDF

A Study on the Reference Model for Integrated Urban Spatial Information Management Platform (지능형 도시공간정보 통합플랫폼 참조모델 개발 연구)

  • Hong, Sang-Ki;Cho, Sung-Youn
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.4
    • /
    • pp.19-27
    • /
    • 2009
  • Integrated Urban Spatial Information Management Platform (USIMP) is defined as an operational environment where technologies for intelligent management of urban facilities are made possible through the integration of diverse technologies such as sensors for ground and underground facilities, middleware technology, wired and wireless network, GIS-USN linkage. To make the integration of these diverse technology possible, it is imperative to have a sound reference model for the platform. This paper provides a standardized reference model for USIMP based on the RM-OPD(Reference Model for Open Distributed Processing) standard.

  • PDF