• Title/Summary/Keyword: 상부 냉각

Search Result 89, Processing Time 0.031 seconds

Development of Cloud Chamber by Using Peltier Device (펠티에 소자를 이용한 안개상자 개발)

  • Woo, Jong-Kwan;Kwon, Jin-Young;Park, Sang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.134-139
    • /
    • 2011
  • In this research, we developed the newly cloud chamber apparatus by using Peltier device to apply nuclear physics experiment in high school or university. We observed the cosmic rays track by using the developed apparatus and a camcorder. And we compared and analyzed the acquired data. From the results, we acquired the following conclusions and suggestions : First, it is very difficult to observe the cosmic rays track in the typical cloud chamber because of the low frequency of it. But in the newly developed cloud chamber we can observe easily the cosmic rays track owing to the high frequency of it. Second, when we do the experiment with the newly developed apparatus, we found that the cosmic rays track happens well under the condition that the temperature of the upper place of cooling plate must be below 5$^{\circ}C$ with more than isopropanol $1.04{\times}10^{-5}$ $ml{\cdot}mm^{-3}$. Third, the newly developed apparatus will be improved to have better precision by controling the temperature of cooling plate in the cloud chamber by current intensity. Therefore we think that it is very useful to use the newly developed apparatus in the nuclear physics experiment in highschool or university.

Hydrogen explosion effects at a containment building following a severe accident (중대사고시 수소폭발이 격납건물에 미치는 영향)

  • Ryu, Myeong-Rok;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • On March 11, 2011, a massive earthquake measuring 9.0 on the Richter scale and subsequent 10-.14 m waves struck the Fukushima Daiichi (FD) Nuclear Power Plant. The main and backup electric power was damaged preventing the cooling system from functioning. Fuel rods overheated and led to hydrogen explosions. If heat in the fuel rods is not dissipated, the nuclear fuel coating material (e.g., Zircaloy) reacts with water vapor to generate hydrogen at high temperatures. This hydrogen is released into the containment area. If the released hydrogen burns, the stability of the containment area is significantly impacted. In this study, researchers performed an explosion analysis in a high-risk explosion area, analyzing the hydrogen distribution in a containment building [1] and the effects of a hydrogen explosion on containment safety. Results indicated that a hydrogen explosion was possible throughout the containment building except the middle area. If an explosion occurs at the top of the containment building with more than 40% of the hydrogen collected or in the bottom right or left side of the of containment building, safety of the containment building could be threatened.

Petrology of the Sanbangsan Lava Dome, Jeju Volcanic Field (제주도 산방산 용암돔(Lava Dome)의 구성암석에 대한 화산암석학적 연구)

  • Yun, Sung-Hyo
    • The Journal of the Petrological Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.307-317
    • /
    • 2019
  • Petrological studies were performed on the Sanbangsan lava dome, located in the southwest of Jeju Island Volcanic Field. According to the lava ejection method, it is 'an internal primitive form' that is gradually pushed up and expanded by continuous magma injection from the bottom to the top of the vent and it corresponds to the 'low lava dome'. The rocks are partly plotted in the field of benmoreite, but mostly plotted in the field of trachyte of the Cox et al.(1979) classification diagram, and also mainly plotted in the field of trachyte of Le Maitre et al.(2002) and Zr/TiO2-Nb/Y classification diagram. Therefore, the expression that described the rock of Sanbangsan lava dome as 'trachy-andesite' should be corrected to 'trachyte'. The volcanic rocks that consists in the Sanbangsan lava dome are trachyte containing normative quartz and shows differentiation trend in the range of 59.75-63.46 wt.% SiO2.

진공 플라즈마 용사코팅시 분말 이송가스 유량이 적층효율에 미치는 영향

  • Jeong, Yeong-Hun;Nam, Uk-Hui;Byeon, Eung-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.161-161
    • /
    • 2014
  • 열플라즈마는 주로 아크 방전에 의해 발생시킨 전자, 이온, 중성입자(원자 및 분자)로 구성된 부분 이온화된 기체로, 국소열평형상태를 유지하여 구성입자가 모두 수천에서 수만도에 이르는 같은 온도를 갖는 고속의 제트 화염 형태를 이루고 있다. 이렇게 고온, 고열용량, 고속, 다량의 활성입자를 갖는 열플라즈마의 특성을 이용하여, 종래 기술에서는 얻을 수 없는 다양하고 효율적인 산업적 이용이 활발히 진행되고 있다. 용사코팅은 노즐 출구를 통해서 외부로 방출되는 열 플라즈마 화염을 이용하는 것으로 이 화염의 와류 특성으로 인하여 외기의 가스가 화염내부로 침투하는 특성을 가진다. 이러한 현상은 열원의 냉각효과 외에도 외기를 구성하는 기체 분자의 내부 유입을 의미하는 것으로 대기 상태에서 공정이 이루어진다면 열원 내로 유입되는 대기 내의 산소가 모재 표면과 반응하여 산화가 진행된다. 이러한 산화과정은 용사 코팅의 품질을 저하시키는 요인이 되므로, W, Ti 등과 같은 반응성이 높은 재료의 코팅은 산화과정을 방지하기 위하여 진공에서 코팅을 하여야만 한다. 진공 플라즈마용사코팅은 진공 또는 저압의 불활성 분위기 중에서 열플라즈마 화염에 용사재료를 투입하여 플라즈마 화염 내부에서 순간적으로 이를 용융시킨 후 고속으로 분출, 모재에 적층시키는 코팅공정이다. 이때 분말상의 용사재료를 고속으로 화염 중심에 투입하여 최대 에너지 전달이 이루어지도록 하는 것이 적층효율 및 코팅품질을 향상에 필수적이다. 하지만 플라즈마 화염 내부를 고속으로 이동하는 입자의 온도와 속도 및 궤적을 측정하여 제어하는 것은 매우 어렵기 때문에, 통상 형성된 코팅의 구조와 두께로부터 경험적으로 파라미터를 결정하는 것이 일반적이다. 본 연구에서는 초고속 레이저 카메라와 이미지 분석용 소프트웨어를 이용하여 플라즈마 화염내의 비행입자 궤적을 추적하고, 이를 통해 분말 이송가스의 유량이 코팅 효율 및 미세구조에 미치는 영향을 조사하였다. 플라즈마 화염은 중심부가 가장 높은 온도와 속도를 가지고 있기 때문에, 분말 이송가스의 유량이 적을 경우 투입된 분말은 단지 플라즈마 화염의 상부 경계면을 지나는 궤적을 갖게된다. 이로 인해 분말의 용융이 충분히 이루어지지 않아 적층 효율이 낮고 미용융 입자 및 기공이 많은 미세구조를 보였다. 이송가스 유량을 증가시키게 되면, 분말의 궤적은 플라즈마 화염의 중심부를 지나게 되어 적층 효율이 증가하고 미세구조 또한 개선되었다. 하지만 이송가스 유량이 지나치게 클 경우, 투입된 분말 입자는 플라즈마 화염을 조기에 관통하게 되어 비행궤적은 온도와 속도가 낮은 영역에 형성되었다.

  • PDF

Low Temperature Storage of Rough Rice Using Cold-Air in Winter (II) - Low Temperature Storage Characteristics of Rough Rice Using a Cooling System in the Top of a Bin - (겨울철 냉기를 이용한 벼의 저온저장 (II) - 빈상부 쿨링시스템을 이용한 냉각 벼의 저온저장 특성 -)

  • Lee, Jae-Seok;Hong, Hyun-Ki;Li, He;Park, Jong-Soo;Ham, Tack-Mo;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.13-19
    • /
    • 2007
  • Storage rough rice in low temperature using the winter cold air avoids rough rice temperature increase which happens from early May, and this is possible by installing a cooling system in the top of a bin, the room between top rice level and bin ceiling. The research objective is to establish low temperature rough rice storage technique, furnishing winter cold air to rough rice, by investigating the cooling system potential of maintaining low rough rice temperature and by analyzing rough rice storage characteristics over a storage period. The rough rice storage characteristics were evaluated from January to August 2003, using a storage and dry bin of 400-ton capacity. Results of this research are as follows: Cooling bin using the cooling system in the top of the bin maintained the rice temperature less than 15$^{\circ}C$ in entire portions in August. Moisture contents and germination rates of rough rice were decreased over the storage period, on the other hand, the rough rice stored in the ambient temperature bin had relatively lower moisture contents and germination rates to compare with the bin using winter cold air. Crack ratio and acid value of brown rice in the ambient temperature bin storage had increased more than the cooling bin storage. The result indicates that the storage bin using winter cold air and the cooling system maintains moisture content and germination of rice, minimizes cracked kernel and acid value, and preserves rice quality as well.

Effect of Variation of Heated Bottom Wall Area on Natural Convection in Square Enclosure with Inner Circular Cylinder (원형 실린더가 존재하는 사각 밀폐계 바닥면의 고온 영역 변화가 자연대류 현상에 미치는 영향)

  • Jo, Hyun Woo;Yoon, Hyun Sik;Lee, Hyo Jeong;Kim, Minsung;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.991-998
    • /
    • 2013
  • A numerical study is carried out for natural convection in an enclosure with an inner hot cylinder at the center. The top wall is cold, the bottom and both side walls of the enclosure are adiabatic, and the cylinder is heated. The bottom wall is heated locally at the middle. The ratio (w) is defined by as the width of the bottom wall to that of the heated local area. The immersed boundary method (IBM) is used to model an inner circular cylinder based on the finite volume method (FVM). This study investigates the effect of w on natural convection in an enclosure with an inner heated cylinder for Rayleigh numbers of $10^6$. At $6Ra=10^6$, thermal and flow fields show time-dependent characteristics after their full development.

A Monitoring Ability of the High-Performance Color CCD Camera under High Dose-Rate Gamma Ray Irradiation Environments (고 선량율 감마선 조사 환경에서의 고성능 칼라 CCD 카메라의 관측성능)

  • Cho, JaiWan;Choi, Young Soo;Seo, Yong Chil;Jeong, KyungMin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.811-814
    • /
    • 2014
  • 일본 후쿠시마 제일 원자력발전소의 대지진/쓰나미에 이은 원자로 건물 수소폭발 사고의 수습 과정에서 사용후 핵연료 저장조에 보관되어 있는 핵연료의 안전문제가 대두되었다. 사용후 핵연료의 잔열 성분을 냉각시키고, 그리고 사용후 핵연료가 방출하는 고선량 방사선을 차폐시키기 위해서 일정 깊이 이상의 수조에 사용후 핵연료를 저장한다. 사용후 핵연료 저장조에 냉각수 공급이 중단되면, 사용후 핵연료의 고유 잔열에 의해 수조의 물이 증발하여 수위가 감소하게 된다. 계속해서 냉각수 공급이 되지 않으면, 사용후 핵연료의 잔열은 증가하게 되고, 수조의 물은 비등하여 증발은 가속화 된다. 사용후 핵연료 저장조의 수위가 고갈되면 고선량의 감마선이 방출된다. 수조의 수위가 정상적일 경우 사용후 핵연료 저장조의 공기중 감마선 선량율은 0.15mSv/h 이다. 수조의 수위가 사용후 핵연료 상부 꼭대기를 기준으로 2m, 1m, 및 0m (핵연료 노출) 로 감소하게 되면, 사용후 핵연료 저장조의 공기중 감마선 선량율은 500mSv/h, 50Sv/h, 및 5kSv/h 로, 급격히 증가한다. 본 논문에서는 사용후 핵연료 저장조 감시카메라의 관측 성능을 평가하기 위해, 고성능 칼라 CCD 카메라에 대해서 1 kGy/h 의 고선량율로 감마선 조사실험을 수행하였다. 이에 대한 실험결과를 기술한다.

Thermal-Hydraulic Research Review and Cooperation Outcome for Light Water Reactor Fuel (경수로핵연료 열수력 연구개발 분석 및 연산학 협력 성과)

  • In, Wang Kee;Shin, Chang Hwan;Lee, Chi Young;Lee, Chan;Chun, Tae Hyun;Oh, Dong Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.815-824
    • /
    • 2016
  • The fuel assembly for pressurized water reactor (PWR) consists of fuel rod bundle, spacer grid and bottom/top end fittings. The cooling water in high pressure and temperature is introduced in lower plenum of reactor core and directed to upper plenum through the subchannel which is formed between the fuel rods. The main thermal-hydraulic performance parameters for the PWR fuel are pressure drop and critical heat flux in normal operating condition, and quenching time in accident condition. The Korea Atomic Energy Research Institute (KAERI) has been developing an advanced PWR fuel, dual-cooled annular fuel and accident tolerant fuel for the enhancement of fuel performance and the localization. For the key thermal-hydraulic technology development of PWR fuel, the KAERI LWR fuel team has conducted the experiments for pressure drop, turbulent flow mixing and heat transfer, critical heat flux(CHF) and quenching. The computational fluid dynamics (CFD) analysis was also performed to predict flow and heat transfer in fuel assembly including the spent fuel assembly in dry cask for interim repository. In addition, the research cooperation with university and nuclear fuel company was also carried out to develop a basic thermal-hydraulic technology and the commercialization.

Petrological Characteristics of the Daejeonsa Basalt in the Mt. Juwang area, Cheongsong-gun, Gyeongsang but-do, Korea (경북 청송군 주왕산지역의 대전사 현무암의 암석학적 특성)

  • Koh, Jeong-Seon;Ahn, Ji-Young;Yun, Sung-Hyo
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.553-562
    • /
    • 2000
  • Daejeonsa basalt in the Mt. Juwang area is composed of 12 lava flows alternate with 9 peperites, and each lava and peperite has variable thickness. Globular peperites yielded in Daejeonsa basalt are mixed basalt clasts with reddish shale. Based on field description, when lava flows over unconsolidated wet shale or injectes into unconsolidated wet shale, peperites were formed at the contacts between lava and shale. Daejeonsa basalt are massive lava flows with rare vesicules: some vesicules are found in upper part of a flow unit. The basalt has mainly pseudomorphs of olivine as phenocryst, and also plagioclase and clinopyroxene phenocrysts in rocks with higher Mg-number. Matrix is mainly subophitic texture, sometimes showing ophitic and intergranular textures due to different cooling rate. Clinopyroxene is augite(Wo$_{41.6}$En$_{45.1}$Fs$_{13.3}$), and plagioclase is mostly labradorite(An$_{55.0}{\sim}_{67.7}$), but some is andesine(An$_{44.3}$) and bytownite(An$_{74.5}$). Oxide minerals are composed of titanomagnetite and ilmenite.

  • PDF

Improvement of Insulation System for LNG Storage Tank Base Slab (LNG 저장탱크 바닥판 단열 시스템 개선)

  • Lee, Yong-Jin;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.141-147
    • /
    • 2010
  • Liquefied natural gas(LNG) is natural gas that has been converted temporarily to liquid form for ease of storage and transport it. Natural gas is the worlds cleanest burning fossil fuel and it has emerged as the environmentally preferred fuel of choice. In Korea, the demand of this has been increased since the first import from the Indonesia in 1986. LNG takes up about 1/600th the volume of natural gas in the gaseous state by cooling it to approximately $-162^{\circ}C(-260^{\circ}F)$. The reduction in volume therefore makes it much more cost efficient to transport and store it. Modern LNG storage tanks are typically the full containment type, which is a double-wall construction with reinforced concrete outer wall and a high-nickel steel inner tank, with extremely efficient insulation between the walls. The insulation will be installed to LNG outer tank for the isolation of cryogenic temperature. The insulation will be installed in the base slab, wall and at the roof. According to the insulation's arrangement, the different aspects of temperature transmission is shown around the outer tank. As the result of the thermal & stress analysis, by the installing cellular glass underneath the perlite concrete, the temperature difference is greatly reduced between the ambient temperature and inside of concrete wall, also reducing section force according to temperature load.