• Title/Summary/Keyword: 상부 기도

Search Result 773, Processing Time 0.032 seconds

Gas and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle -Effects of Flow Zone Sizes- (단일노즐을 사용한 내부순환 공기리프트 반응기에서 기체 및 액체의 유동특성 - 유동지역의 크기영향 -)

  • Jang, Sea-Il;Kim, Jong-Chul;Jang, Young-Joon;Son, Min-Il;Kim, Tae-Ok
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.901-906
    • /
    • 1998
  • Gas and liquid flow characteristics were investigated in an internal circulation airlift reactor using a single nozzle for a gas distributor. In three reactors with different diameters of the downcomer and heights of the riser, the gas holdup in the individual flow zone and the impulseresponse curve of tracer for an air-water system were measured for various gas velocities and reactor heights. Experimental results showed that the flow behavior of bubbles in the riser was the slug flow due to strong coalescences of bubbles and that the bubble flow pattern in the downcomer was the transition bubble flow for the smaller diameter of the downcomer, however, it was the homogeneous bubble flow for the larger one. And mean gas holdups in the individual flow zone and the reactor were greatly increased with decreasing the diameter of the downcomer for the equal ratio of height of the top section to that of the riser. Also, the mixing time was much effected by the height of the top section of reactor and for the equal ratio of height of top section to that of the riser, it was increased with increasing the diameter of the downcomer and the height of the riser. Flow characteristics of liquid were mainly varied with the bubble flow pattern in the downcomer and the size of the top section of reactor. And circulation velocities of liquid in the riser were increased with increasing gas velocities and the size of the top section of reactor, and for the equal ratio of height of top section to that of the riser, they were increased with increasing the diameter of the downcomer and the height of the riser.

  • PDF

I-형 마멸 손상된 증기발생기 전열관의 파열압력해석

  • 신규인;박재학;정명조;최영환
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.38-43
    • /
    • 2003
  • 증기발생기 전열관의 마멸은 유체 유발 진동(flow induced vibration)에 의한 전열관과 증기발생기 상부 지지구조물 사이에서 발생하게 되며 원통 지지대(stay cylinder)상부의 중앙 공공(central cavity) 주변에 집중적으로 발생되는 것으로 보고되고 있다. 국내에서는 1997년 영광 4호기의 증기발생기에 마멸 손상이 보고된 이후 영광 3호기와 울진 3, 4호기에서도 마멸 손상이 발견되고 있으며, 외국에서는 1992-1993년 기간동안 대략 500∼600 개의 전열관이 마멸에 의해 관막음(p1u99ing)된 것으로 보고되었다.(중략)

  • PDF

A study on the life prolongation of pad mounted transformer through the improvement of heat radiation (지상변압기 방열 개선을 통한 수명연장에 관한 연구)

  • Chun, Sung-Nam;Park, Chul-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.503-503
    • /
    • 2007
  • 본 논문에서는 지중배전(22.9kV) 선로에 사용되는 지상변압기를 대상으로 수행한 방열해석 및 개선과 변압기수명연장에 관한 검토 결과를 수록하였다. 변압기의 열화메커니즘에 대한 문헌 조사를 통해 변압기 온도와 수명간의 관계를 작도하였는바, 수명 평가를 위한 핵심 인자로 열에 의한 절연지의 열화에 초점을 맞추었다. 기존 외함에 설치된 방열구중 상부 위치를 상부판에도 변경하는 경우 약25%의 통풍량 증가 효과를 기대할 수 있을 것으로 평가 되었으며 상부판과 내함 사이에 형성되던 고온 영역에서의 온도를 약$15^{\circ}C$정도 낮출 수 있는 것으로 나타났다. 절연지의 인장강도 변화로 평가한 수명예측 곡선에 따르면 약$10^{\circ}C$의 은도 저감은 약10배의 수명 연장 효과를 가져오는 것으로 나타난바, 본 연구에서 확인한 방열구의 위치 변경에 따른 지상기기 내부의 온도 저하는 변압기 수명을 연장하는데 일조할 것으로 기대된다. 기존 지상변압기에서의 방열구조를 통해 변압기 온도와 수명간의 관계를 작도하였는바, 수명 평가를 위한 핵심인자로 효과적으로 방열할 수 있는 새로운 외함의 구조 및 디자인을 제시하고 시뮬레이션을 통해 개선효과를 예측하였다. 또한, 개선된 모델을 가지고 실제 변압기를 제작한 후 부하를 인가하여 개선전과 후에 대한 방열효과를 실증시험을 통해 확인하였다.

  • PDF

Synchronization of Flowering for Hybrid Com Seed Production by Clipping Young Plants Clear Polyethylene Mulching and Planting Date (옥수수 교잡종채종에 있어 유식물절단 비닐피복 및 파종기에 의한 자식계통 개화기조절)

  • Kang, Y.K.;Park, K.Y.;Ham, Y.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.4
    • /
    • pp.481-487
    • /
    • 1983
  • The need to synchronize flowering in two lines of different maturities is frequently encountered in hybrid com (Zea mays L.) seed production. To establish the methods for synchrony of flowering in parent lines of different maturities be effects of clipping at 4 and 6-leaf stages of growth and two levels, clear polyethylene mulching and five different planting dates on flowering date growth and seed yield of two dent com inbred lines of different maturities were evaluated Clipping just above the shoot-apex delayed pollen sheeding 6 to 9days and silking 5 to 13 days but reduced stand and seed yield 30 to 70% and 67 to 81%. respectively. Clipping 5cm above the shoot apex delayed flowering 1 to 4 days without stand reduction but reduced yield 3 to 29%. Laterclipping was slightly more effective for delaying flowering than earlier clipping but reduced stand more severely when clipped just above the shoot apex. Under clear polyethylene film mulching, flowering of two lines was 13 to 15 days earlier and seed yield of B68 (late line) was significantly increased. As planting was delayed from April 18 to June 13, the number of days from planting to flowering of two lines decreased due to increase in air temperature. However, growing degree days (GDD) from planting to flowering of each lines was similar regardless planting dates indicating that GDD can be satisfactoryly used for choosing the planting dates of parent lines of different maturities. Seed yields of two lines were decreased with delaying planting dates.

  • PDF

상부기도 협착의 나선식 CT를 이용한 3차원 영상의 진단적 의의

  • 김승현;김현웅;노영수;임현준;윤대영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1997.04a
    • /
    • pp.119-119
    • /
    • 1997
  • 상부기도 협착의 원인은 장기간의 기관 삽관, 외상, 감염, 종양, 및 선천적인 결함등에 의해 존재하며, 이에 대한 진단은 단순 촬영이나 전산화 단층 촬영술 등으로 쉽게 진단은 가능하나, 적절한 치료 계획을 세우기 위해서는 그 범위 및 정도를 정확히 파악하는 일이 중요하다 최근 방사선 촬영기술의 발달로 현재의 2차원적 단면 영상에서 3차원적 영상으로 발전해왔으며 상부기도 협착 또한 3차원적 영상으로 진단하려는 노력이 시도되고 있다. 이에 저자들은 최근에 경험한 기관 협착증 7례에서 3D CT를 시행하여 협착 부위의 상태를 기존의 단순 촬영 영상 및 2D CT 영상과 비교하였고, 7례의 기관 협착증 중 4례에서 기관 단단 문합술 및 후두 기관 문합술을 시행한 바 수술시 확인된 협착 상태를 3D CT 영상과 비교하였다.

  • PDF

Late Quaternary Stratigraphy and Unconformity of the Banweol Tidal-Flat Deposits(upper tidal flat) and Unconformity, Kyunggi Bay, West Coast of Korea (한국 서해 경기만 반월 조간대(상부조간대) 퇴적층의 제4기 후기 층서와 부정합)

  • 박용안;임동일;김수정
    • The Korean Journal of Quaternary Research
    • /
    • v.14 no.2
    • /
    • pp.125-135
    • /
    • 2000
  • The late Quaternary stratigraphy and basal unconformity (nonconformity) of the intertidal deposits (upper tidal flat) in the Banweol tidal basin in the Kyunggi Bay, west coast of Korea has been investigated and established. The Unit I (middle to late Holocene upper intertidal deposit) and Unit II (pre-Holocene fluvial to alluvial deposit) in descending order are classified and interpreted. The basement rocks of the Banweol tidal basin is dominantly preCambrian metamorphic rocks on which Unit II is overlying unconformably. In short, the late Quaternary stratigraphy and unconformity of the Banweol tidal flat deposits are established and interpreted in terms of sedimentology and sea-level fluctuation history during late Quaternary.

  • PDF

Analysis of side-polished fiber couplers with an intermediate-coupling layer and improvement of their coupling efficiency (중간 결합층이 적층된 측면연마 광섬유 결합기의 해석 및 결합효율 개선)

  • 손경락;김광택
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.28-33
    • /
    • 2004
  • An in-line fiber coupler, based on side-polished single-mode fibers covered with an intermediate coupling layer and a planar waveguide, is analyzed by modeling the interaction region as an equivalent multi-layered planar waveguide. The reflectance for the multi-layered structure with and without buffer layer is illustrated as a function of the refractive index and thickness of the overlay waveguides. When the refractive index of the overlay waveguides is greater than that of the fiber core, the conditions for the intermediate coupling layer to increase the power coupling from the fiber to the overlays is also explained. Through the experimental results using a LiNbO$_3$planar waveguide, we show that the theoretical analysis is reasonable and in good agreement with the measured values.

Analysis of Natural Frequency Change of Pier According to Bridge Superstructure Modeling Methods (교량 상부구조물의 모델링 방법에 따른 교각 고유진동수 변화분석)

  • Park, Byung-Cheol;Chang, Sung-Hee;Kim, Young-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.187-190
    • /
    • 2010
  • 기초세굴에 따른 교각에서의 1차 모드 고유진동수 변화를 이용하여 교량 세굴 건전성을 정량적으로 평가하기 위하여 공용중인 광탄1교의 T형 교각 1기에 대하여 충격진동실험을 수행하였으며, 교축직각방향의 1차 모드 고유진동수를 수치해석결과와 비교하였다. 교량 상부구조물의 모델링 방법에 따라 상부구조물을 전체 모델링한 방법과 교각만을 모델링하고 상부구조물의 영향범위를 가정하여 교량받침 위치에 질점질량으로 변환하여 적용한 방법으로 구분하여 수치해석을 수행하였다. 상부구조물을 전체 모델링한 경우와 집중하중 형태로 상부구조물을 모델링한 경우 모두 고유진동수는 충격진동실험결과와 큰 차이를 보였다. 충격진동실험을 통해 얻은 고유진동수는 교각의 국부적인 진동수로 사료되는 반면, 수치해석을 통해 구한 결과는 교량 상부와 하부의 Coupling 효과가 반영된 시스템 전체의 고유진동수이기 때문에 결과의 큰 편차가 생기는 것으로 판단된다. 따라서 충격진동실험에서 구한 고유치 양상을 올바로 구현하기 위한 모델링을 찾기 위해서는 새로운 접근 방법이 필요할 것으로 사료된다.

  • PDF

Excavation Design and Vibration Analysis for the Crossing Under a Railway Station (정거장 구조물 횡단 굴착 설계 및 진동 해석)

  • ;;Reijo Riekkola
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.505-512
    • /
    • 1998
  • 지하철과 같은 지하구조물 설계시 기존 구조물 지하를 관통하는 경우가 있다. 본 논문은 기존 역사의 바닥슬래브 밑에 새로운 지하철용 박스 구조물 상부 슬래브가 위치하게 되는 특별한 경우의 굴착 방법을 제시하고 제시된 굴착방법이 상부 구조물에 어떤 영향을 미치는지를 FLAC을 이용하여 검토해 본 것이다. 기존 구조물이 위치하고 있는 지반이 경암인 경우 발파가 주의 깊게 설계되고 시행된다면 발파로 인한 상부 구조의 진동 영향은 충분히 제어할 수 있는 수준으로 예상되었다.

  • PDF