• Title/Summary/Keyword: 상부시설

Search Result 172, Processing Time 0.029 seconds

Conducted to Verify the Effect of Chlorine Dioxide (ClO2) on Odor Reduction at a Commercial Swine Facility (이산화염소 가스분무에 의한 양돈장 악취저감 효과)

  • Song, J.I.;Jeon, J.H.;Park, K.H.;Yoo, Y.H.;Kim, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.43-50
    • /
    • 2011
  • This study was conducted to verify the effect of chlorine dioxide ($ClO_2$) on odor reduction at a commercial swine facility consisting of a windowless piglet barn and a grower/fattening barn. The windowless piglet barn used a duct ventilation system. Air velocity at very below the upper duct was 4.53 m/s. Air velocity at the lower space around the living space of pigs in the grower/fattening barn was 0.26 m/s. $NH_3$ concentration was around 9ppm and less than 3 ppm before and after the $ClO_2$ spraying, respectively, which was over 70% reduction. There was no $H_2S$ detection. $NH_3$ concentrations measured in the windowless grower/fattening barn and at the exhausted air were 26 ppm and 11ppm, respectively. $NH_3$ concentration at a biocurtain outside was less than 1 ppm. Hence, $ClO_2$ spraying at windowless barns was effectively decreased malodor such as $NH_3$.

Measurements of Greenhouse Gas from the Manure in the Piggery (축산 돈사에서 온실가스 측정 방법에 대한 연구)

  • Kam, D.H.;Park, K.H.;Choi, D.Y.;Jung, M.S.;Min, B.R.;Lee, D.W.;Kim, J.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.155-162
    • /
    • 2011
  • This study was conducted to suggest the measurement procedure and to build up national greenhouse gas inventory database of animal agricultural sector by assessing methane and nitrous oxide emissions according to IPCC guidelines for national greenhouse gas inventory report in order to correspond to the Climate Change Convention. Ten house-made steady-state Half dome floating chambers were used to collect air samples emitted from slurry stored in the pit under the slat. Those chambers were spread out in order that air samples might represent the whole area of slurry under the slat. Fresh air was pumped into the chambers by $5{\sim}9{\ell}/min$ and air inside the chambers was sampled by $1{\ell}/min$. Surplus air by the higher flow rate of fresh air than sampling flow rate was passed through a hole on the top of chambers. Nitrous oxide fluxes measured from 10 locations would be negligible as concentrations between background air and sampled air from the chambers were within the error range. However, mean $CH_4$ fluxes were $0.15{\sim}1.02mg/m^2{\cdot}s$. The application of continuous greenhouse gas measurement techniques would be preferred if the patterns of greenhouse gas emissions are considered.

Case study on the cause of failure and characteristics of soil at a collapsed cut-slope at the ${\bigcirc}{\bigcirc}$ Detour, Jeonranam-Do (전라남도 ${\bigcirc}{\bigcirc}$우회도로 비탈면 붕괴발생원인 및 토사지반특성 사례 연구)

  • Kim, Seung-Hyun;Koo, Ho-Bon;Hwang, Jin-Hyun;Son, Moon
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.313-322
    • /
    • 2011
  • On September 2007, numerous slopes at Jeonranam-Do collapsed as a result of rainfall related to Typhoon Nari. Failure occurred at a road cut-slope on the ${\bigcirc}{\bigcirc}$ detour road, damaging transport infrastructure. This study aims to determine the cause of failure based on field investigations, the geotechnical properties of soil, clay mineral composition, and quantitative analysis. The studied cut slope consists of weathered soil that originated from volcanic rocks, and minor faults and a mafic dyke. Surface water tends to seep into the soil because the roadway is not sealed and because of poorly installed drainage. Sieve and XRD analyses indicate that soils in the failure zone are ML and CH, which are prone to swelling due to the presence of clay minerals such as smectite and vermiculite. The slope failed due to the improper construction of drainage facilities, the presence of geological weak zones, and high soil contents of swelling clay.

Evaluation of the Stability of Geomembrane Liner System in Closed Waste Landfill (사용종료 폐기물 매립장의 멤브레인 차수시스템 안정성 평가)

  • Lee, Heung-Gil;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Recently, the effective use of closed waste landfill nearby urban areas has been demanded, because of the lack of the usable land. However, the reuse of closed landfill is needed an adequate stabilization of liner system. But most of these places are consisted of steep slope and hence it is necessary to use the geosynthetics liners in there. Liner system of waste landfills is an important facility which prevents leachate outgoing from the landfills and also groundwater infiltrating from surroundings into the landfills. During the waste disposal stage, differential settlement and tensile stress of the geosynthetic materials could occur due to impact load of trucks and dozers, waste loads and weak foundation soils. In this study, the tensile strength and tracer test were performed to evaluate the stability of geomembrane liner systems. Based on the tensile strength test result of in-situ geomembrane sample, the yield tensile strength maintain the suitable strength by specification and current law. However, according to the tracer test, the damage of geomembrane liner was detected on sanitary landfill section.

  • PDF

Evaluation of Neutron Detection Efficiency of the Unified Non-Destructive Assay Using MCNPX Code (MCNPX 코드를 이용한 통합비파괴측정장치의 중성자 검출 효율 평가)

  • Won, Byung-Hee;Seo, Hee;Lee, Seung Kyu;Park, Se Hwan;Kim, Ho Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.172-178
    • /
    • 2013
  • In this study, neutron detection efficiency of the UNDA system, which has been developed for study on nuclear material accountancy in a future pyro-process facility, was evaluated by using the MCNPX code. The detection efficiency was evaluated as a function of (1) positions of $^{252}Cf$ neutron source in the axial and radial directions, and (2) thicknesses and locations of the container filled with the depleted uranium materials for two different designs of the UNDA. In the case of $^{252}Cf$ source positions, detection efficiency was distributed from 6.83% to 13.35%. As $^{252}Cf$ source was positioned at upper part in the axial direction, detection efficiency was decreased after a slight increase. On the other hands, as $^{252}Cf$ source was positioned at outer part in the radial direction, detection efficiency was increased. In the case of container thickness, there was a slight decline when the thickness was increased. As the container was located at upper part, detection efficiency was decreased and as the container was located at outer part, detection efficiency was increased. Detection efficiency was varied from 10.31% to 13.61%. These values were higher than that of $^{252}Cf$ source case. The UNDA with polyethylene cover has about 2% higher detection efficiency than the UNDA without the cover.

Evaluation of Active Layer Depth using Dynamic Cone Penetrometer (동적 콘 관입기를 이용한 활동층 심도평가)

  • Hong, Won-Taek;Kang, Seonghun;Park, Keunbo;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2016
  • An active layer distributed on surface of an extreme cold region causes a frost heave by repeating the freezing and thawing according to the seasonal temperature change. Since the height of frost heave is greatly affected by the thickness of active layer, an accurate evaluation of the thickness of active layer is necessary for the safe design and construction of the infrastructure in the extreme cold region. In this study, dynamic cone penetrometer, which is miniaturized in-situ penetration device, is applied for the evaluation of active layer depth distribution. As the application tests, two dynamic cone penetration tests were conducted on the study sites located in Solomon and Alaska. In addition, ground temperature variations were obtained. As the results of the application tests, the depth of interface between the active layer and the permafrost was evaluated from the difference in dynamic cone penetration indexes of the active layer and the permafrost, and a layer was detected around the interface considered as an ice lens layer. Also, the interface depths between the above zero and the below zero temperature determined from the ground temperature variations correspond with the interface depths evaluated from the dynamic cone penetration tests. This study demonstrates that the dynamic cone penetrometer may be a useful tool for the evaluation of the active layer in the extreme cold region.

Development of Scour Depth Calculation Equation Based on Hydraulic Model Test Data (수리모형실험 자료를 활용한 교각세굴심 산정식의 개발)

  • Chang, Hyung-Joon;Lee, Ho Jin;Lee, Hyo Sang;Kim, Sung-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.163-168
    • /
    • 2020
  • Since the industrialization in the 1960s, Korea has been expanding its transportation infrastructure, such as building bridges. Owing to bridge construction, studies on stability review have been carried out, and stability-securing technology has been developed. On the other hand, these were applied mainly to the upper part of the bridge, so applications to the lower part are limited. In particular, scour at the bridge pier causes erosion in the riverbed and bridge collapse. Hence, prevention studies and countermeasures are needed. In this study, an empirical formula was developed to evaluate the scour depth of a bridge, which was calculated through multiple linear regression analysis using the hydraulic model study data conducted in previous studies. The formula, which had a value of 0.91, was applied to the model test data that was not used for development to verify the developed formula. When the pier scour depths were compared in 23 cases, the error rate was less than 20% in 16 cases (70%). The empirical formula developed in this study is applicable to pier scour-depth calculations. Further research will be needed to develop a more accurate empirical formula for pier scour-depth calculations, and it is expected to reduce bridge damage caused by scour.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

A Design Aspects of Historic Parks Preserving Buried Cultural Heritages - In the Case of Neunggok Prehistoric Remains Park, Ansan Singil Historic Park, Yongjuk Historic Park - (매장문화재 보존형 역사공원의 설계 양상 - 능곡선사유적공원, 안산신길역사공원, 용죽역사공원을 대상으로 -)

  • Kim, Ki-Uk;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.12-22
    • /
    • 2019
  • This study derived the design aspects by carrying out the case study of Neunggok prehistoric remains park, Ansansingil historic park and Yongjuk historic park to which are taken measures to preserve undesignated cultural heritages after studying the related laws & regulations and the systems as the design conditions of historic park preserving buried cultural heritages. The results of the study are as follows. First, according to the laws & regulations related to the historical parks, the historic sites should be preserved and utilized at the same time and can have history-related facility spaces, squares, rest spaces, exercise spaces, education & culture space, and convenience spaces. Second, by the space organization and the circulation system emphasizing only the preservation of buried cultural heritages, the feature-preservation space and the functional space are separated and due to not accepting the usage behavior considering peripheral land use, the effectiveness of the historical park was low. Third, the passive feature-preservation methods such as the preservation of the exposed site in architectural methods, the reproduction of the dugout hut, and the planting Royal azaleas or displaying stone after covering up the location of the pit dwellings with soil and the usage mainly for viewing have weakened the identity of the historical park. Fourth, the fence preventing users' access interferes experiencing the features, and the vertical structure protecting the upper part of the exposed features has overwhelmed the landscape of the historical parks. Fifth, it was difficult to figure out the feature space only by the texts mainly on terminologies and the excavation photographs presented on the information signs which introduce the buried cultural heritages.

Analysis of support loads in large underground space for high-density arrangement of complex plant (복합플랜트 고집적 배치를 위한 지하대공간 지지하중 해석)

  • Kim, Sewon;Park, Jun Kyung;Lee, Sangjun;Kim, YoungSeok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.2
    • /
    • pp.77-92
    • /
    • 2021
  • For the construction of a large underground space with a complex plant installed, it is necessary to analyze the stability considering the ground conditions and various load conditions. In this paper, finite element analysis was performed to analyze the support load that can be used in the design of a large underground space for high-density arrangement of complex plant. An analysis of underground continuous wall (D-wall) was performed considering the load and horizontal earth pressure in the large underground space. In addition, foundation ground analysis was carried out according to the load condition of the complex plant. In order to shorten the construction period, increase the space layout utilization, and secure the stability of the plant structure when installing the complex plant underground, the pipe rack module structure analysis was conducted. This study proposes a design and construction method for the optimal arrangement of underground complex plants using the analysis results.