• Title/Summary/Keyword: 상대적 세기 잡음

Search Result 10, Processing Time 0.033 seconds

Phenomenological Nonlinear Gain Saturation Effect on the Noise Characteristics of a Multi-electrode DBR Laser with Continuous Frequency Tuning (연속 파장 가변시 현상론적인 비선형 이득포화효과가 다전극 DBR 레이저의 잡음특성에 미치는 영향)

  • 이석목;최원준;한일기;김회종;우덕하;김선호;이정일;감광남;박홍이
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.135-141
    • /
    • 1995
  • Phenomenological nonlinear gain saturation effect on the noise characteristics of a multi-electrode DBR laser, when the lasing wavelength changes continuously, is presented theoretically. Using the optical transmission line theory, noise characteristics reliant on output power are analyzed by taking into account both the spontaneous enhancement factor K due to the distribution of the spontaneous emission along the active cavity and the nonlinear gain saturation effect. Spontaneous emission rate was increased due to an increase in injected current into the passive section, which in turn lead to increase in relative intensity noise (RIN) and frequency noise. Phenomenological nonlinear gain saturation was found to have significant effect on RIN and frequency noise characteristics. However. Iinewidth was found to decrease due to a phenomenological nonlinear gain saturation effect. ffect.

  • PDF

Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images (2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • Purpose: To simulate and measure the signal intensity of various tissues near bone interface in 2D and 3D neurological MR images. Materials and Methods: In neurological proton density (PD) weighted images, every component in the head including cerebrospinal fluid (CSF), muscle and scalp, with the exception of bone, are visualised. It is possible to acquire images in 2D or 3D. A 2D fast spin-echo (FSE) sequence is chosen for the 2D acquisition and a 3D gradient-echo (GE) sequence is chosen for the 3D acquisition. To find out the signal intensities of CSF, muscle and fat (or scalp) for the 2D spin-echo(SE) and 3D gradient-echo (GE) imaging sequences, the theoretical signal intensities for 2D SE and 3D GE were calculated. For the 2D fast spin-echo (FSE) sequence, to produce the PD weighted image, long TR (4000 ms) and short TE$_{eff}$ (22 ms) were employed. For the 3D GE sequence, low flip angle (8$^{\circ}$) with short TR (35 ms) and short TE (3 ms) was used to produce the PD weighted contrast. Results: The 2D FSE sequence has CSF, muscle and scalp with superior image contrast and SNR of 39 - 57 while the 3D GE sequence has CSF, muscle and scalp with broadly similar image contrast and SNR of 26 - 33. SNR in the FSE image were better than those in the GE image and the skull edges appeared very clearly in the FSE image due to the edge enhancement effect in the FSE sequence. Furthermore, the contrast between CSF, muscle and scalp in the 2D FSE image was significantly better than in the 3D GE image, due to the strong signal intensities (or SNR) from CSF, muscle and scalp and enhanced edges of CSF. Conclusion: The signal intensity of various tissues near bone interface in neurological MR images has been simulated and measured. Both the simulation and imaging of the 2D SE and 3D GE sequences have CSF, fat and muscle with broadly similar image intensity and SNR's and have succeeded in getting all tissues about the same signal. However, in the 2D FSE sequence, image contrast between CSF, muscle and scalp was good and SNR was relatively high, imaging time was relatively short.

  • PDF

Tunable laser source using a self-seeding FP-LD (Self-seeding FP-LD을 이용한 파장 가변 레이저 광원)

  • Kim, Jung-Min;Lee, Hyuek-Jae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.104-109
    • /
    • 2021
  • In this paper, we experimentally demonstrate a self-seeding FP-LD (Fabry Perot Laser Diode) to verify the possibility of a new tunable light source that can be used in WDM-PON (Wavelength Division Multiplexing - Passive Optical Network) system. The conventional implementation of WDM-PON using a tunable light source has a disadvantage that the center wavelength of the AWG (Arrayed Waveguide Grating) device and the tunable light source must be precisely aligned. However, the proposed tunable light source has the advantage that the tunable wavelength is automatically aligned with the center wavelength of the AWG as well as simple structure. The implemented tunable light source had a tunable band of about 14 nm or more, and the maximum RIN (Relative Intensity Noise) of about -124 dB/Hz, which showed the possibility of modulating 10 Gb/s signal by an external modulator.

Analysis of Quantization Noise in Magnetic Resonance Imaging Systems (자기공명영상 시스템의 양자화잡음 분석)

  • Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 2004
  • Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.

  • PDF

Signal Processing for Pulse Induction Metal Detector (자성센서 기반 지뢰탐지기를 위한 신호처리)

  • Shin, Beom-Su;Yang, DongWon;Jung, Byung-Min
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.532-538
    • /
    • 2018
  • This paper proposes an algorithm for signal processing which is used in pulse induction metal mine detectors. The detection power can be obtained from magnetic variation on the search coil. The calibration data should be made when there is no target because the detection power is difference between with and without a target. And it is also updated periodically because of surrounding various noises. Lastly, we keep a watch on the signal slope to identify exact position and signal power of mine detection.

Cost Effective Mutual Injection Locked F-P LD for WDM-PON System (WDM-PON 시스템을 위한 저가격 상호 주입 잠김 F-P LD)

  • Hwang, Ji-Hong;Lee, Hyuek-Jae;Park, Jun-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.162-169
    • /
    • 2020
  • In this paper, we attempted a qualitative understanding of mutual injection locking without rigorous mathematics, and analyzed the proposed mutual injection locked light source. Also, a low-cost WDM-PON light source based on mutual injection locking using two unpolarized Fabry-Perot Laser Diodes (F-P LDs), was implemented. The RIN (Relative Intensity Noise) characteristic for the wavelength change of the F-P LD was measured, and when the variable wavelength range was 2.07 nm, it showed a RIN of at least -110 dB/Hz.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Radio Frequency Interference on the GNSS Receiver due to S-band Signals (S 대역 신호에 의한 위성항법수신기의 RF 신호간섭)

  • Kwon, Byung-Moon;Shin, Yong-Sul;Ma, Keun-Su;Ju, Jeong-Gab;Ji, Ki-Man
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.5
    • /
    • pp.388-396
    • /
    • 2019
  • This paper describes the RF(Radio Frequency) interference on the GNSS receiver due to the S-band signals transmitted from the transmitters in the Test Launch Vehicle, and analyzes the cause of the RF interference. Due to the S-band signals that have relatively high power levels compared with GNSS signals, an LNA(Low Noise Amplifier) in the active GNSS antenna was saturated, and the intermodulation signal within GNSS in-bands was produced in the LNA whenever two S-band signals were received from the GNSS antenna. For these reasons, the C/N0 of the satellite signals in the GNSS receiver was attenuated severely. The design of the LNA was changed in order to protect the RF interference due to the S-band signals and the suppression capability of the RF interference was confirmed in the new LNA through the comparison of the old LNA.

Frequency stabilization of 1.5μm laser diode by using double resonance optical pumping (이중공명 광펌핑을 이용한 1.5μm 반도체 레이저 주파수 안정화)

  • Moon, Han-Sub;Lee, Won-Kyu;Lee, Rim;Kim, Joong-Bok
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.193-199
    • /
    • 2004
  • We present the double resonance optical pumping(DROP) spectra in the transition 5P$_{3}$2/-4D$_{3}$2/ and 5P$_{3}$2/-4D$_{5}$ 2/ of ($^{87}$ Rb) and the frequency stabilization in the $1.5mutextrm{m}$ region using those spectra. Those spectra have high signal-to-noise ratio and narrow spectral linewidth, which is about 10 MHz. We could account fur the relative intensities of the hyperfine states of those spectra by the spontaneous emission into the other state. When the frequency of the $1.5mutextrm{m}$ laser diode was stabilized to the DROP spectrum, the frequency fluctuation was about 0.2 MHz fDr sampling time of 0.1 s and the Allan deviation(or the square root of the Allan variance) was about 1${\times}$10$^{-11}$ for averaging time of l00s.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.