• Title/Summary/Keyword: 삽입 금속

Search Result 338, Processing Time 0.025 seconds

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire (세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이)

  • Choi, Yoon-Jeong;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.207-217
    • /
    • 2006
  • Although ceramic brackets have been used widely for improved esthetics during treatment, ceramic brackets have some inherent problems; brittleness, attrition of the opposing teeth and high frictional resistance. This study was performed to understand the frictional resistance of the ceramic brackets, as well as to be a helpful reference for finding the solutions to the problem of frictional resistance. Three different kinds of brackets were used; metal bracket, polycrystalline ceramic brackets with a metal slot to reduce the high frictional resistance and monocrystalline ceramic brackets. The brackets were tested with a $.019{\times}.025$ stainless steel wire with a second order angulation of $0^{\circ}\;and\;10^{\circ}$, and the static and kinetic frictional forces were measured on the universal testing machine. The results of this study showed that the ceramic brackets, especially the monocrystalline ceramic bracket without a metal slot, generated higher frictional resistance than the metal bracket, and the frictional resistance was increased as the angulation between the bracket slot and the wire increased. Therefore, the development of the ceramic bracket with reduced frictional resistance and the prevention of excessive crown tipping during orthodontic treatment will lead to the simultaneous attainment of more efficient and improved esthetic treatment goals.

Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study (토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험)

  • Daegun, Kim;Jaehong, Jung;Sungchul, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.709-718
    • /
    • 2022
  • We evaluated the effect of high-density aluminum, titanium, and steel metal inserts on computed tomography (CT) numbers and radiation treatment plans for Tomotherapy. CT images were obtained using a cylindrical TomoPhantom comprising cylindrical rods of various densities and metal inserts. Three CT image sets were evaluated for image quality as the mean CT number and standard deviation. Dose evaluation also performed. The reference values did not significantly differ between the CT image sets with the corrected metal inserts. The higher-density material exhibited the largest difference in the mean CT number and standard deviation. The conformity index at Iterative-Metal Artifact Reduction (iMAR) was approximately 20% better than that of non-iMAR. No significant target or organ at risk dose difference was observed between non-iMAR and iMAR. Therefore, iMAR is helpful for target or organ at risk delineation and for reducing uncertainty for three-dimensional conformal radiation therapy in Tomotherapy.

Diffuse Large B-Cell Lymphoma Associated with a Chronic Inflammatory Condition Induced by Metallic Implants: A Case Report (금속성 임플란트로 인한 만성 염증 상태와 연관된 미만성 거대 B세포 림프종: 증례 보고)

  • Jin Hee Park;Sun Joo Lee;Hye Jung Choo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.931-937
    • /
    • 2022
  • Chronic inflammatory condition associated with metallic implant insertion is a risk factor for diffuse large B-cell lymphoma (DLBCL). Metal ions play a role in the pathogenesis of lymphoma. We report a rare case of DLBCL in a patient who had a metallic implant in the proximal tibia for 15 months. Radiologic studies, including US and MRI, showed disproportionately large extraosseous soft-tissue mass and bone marrow involvement without prominent bone destruction. Multiple complications are associated with metallic implants, and misdiagnosis may lead to inappropriate treatment. Therefore, distinguishing lymphomas caused by a metallic implant-induced chronic inflammatory condition from other periprosthetic benign lesions and malignant soft tissue masses is challenging, but it is critical.

TCharge trap 층에 금속 공간층 삽입에 따른 charge trap flash 메모리 소자의 전기적인 특성

  • Lee, Dong-Nyeong;Jeong, Hyeon-Su;Kim, Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.200.1-200.1
    • /
    • 2015
  • Charge trap flash (CTF) 메모리 소자는 기존의 플로팅 게이트를 사용한 플래시 메모리 소자에 비해 쓰고 지우는 속도가 빠르고, 소비 전력이 적으며, 쓰고 지우는 동작에 의한 전계 스트레스에 잘 견뎌내는 장점을 가지고 있다. 그러나 CTF 메모리 소자에서도 메모리 셀의 크기가 작아짐에 따라 셀 사이의 간섭 효과를 무시할 수 없다. 인접 셀 간의 간섭현상은 측정 셀의 문턱전압을 예측할 수 없게 변화시켜 소자 동작의 신뢰성을 낮추고 성능을 저하시킨다. 본 논문에서는 셀 사이의 간섭을 줄이고 소자의 성능을 향상시키기 위해 charge trap 층에 금속 공간층을 삽입한 CTF메모리 소자의 전기적인 특성에 대해 연구하였다. 금속 공간층을 갖는 CTF 메모리 소자는 기존 CTF 메모리 소자의 트랩층 양 측면에 절연막과 금속 공간층을 증착시켜 게이트가 트랩층을 감싸는 구조를 갖는다. 인접 셀 사이에 발생하는 간섭 현상과 전계 분포를 분석하였다. 프로그램 동작 시CTF 메모리 소자 내에 형성되는 전계의 분포와 크기를 계산함으로 금속 공간층이 인접한 셀에서 형성된 전계를 차폐시켜 셀 간 간섭 현상을 최소화하는 것을 확인하였다. 이러한 결과는 인접 셀 간의 간섭현상을 최소화하면서 소자 동작의 신뢰성이 향상된 대용량 메모리 소자를 제작하는데 도움을 줄 수 있다.

  • PDF

Optimized Brazing Conditions of Regenerative Cooling Thrust Chambers (재생 냉각용 연소기의 최적 브레이징 조건)

  • Nam,Dae-Geun;Hong,Seok-Ho;Han,Gyu-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.112-117
    • /
    • 2003
  • The brazing of copper alloys and duplex stainless steels is an indispensable manufacturing technology for thrust chambers with regenerative cooling. For setting up the optimized brazing conditions, C18200 copper alloy plate with machined cooling channels and S31803 stainless steel plate are brazed with AMS4764 filler metals of which thickness is 50${\mu}m$ and 80${\mu}m$ They are tested by X-ray radiography, strength/leakage and fracture tests, and fracture surface inspection. The results obtained by the suggested conditions are that the specimen brazed with filler metal thickness of 50${\mu}m$ has good strength properties and brazed zone. However, the specimen with filler metal thickness of 80${\mu}m$ has the brazed zone with cooling channel obstruction and enlargement.

Design and Fabrication of a Ka-Band Fin-line Filter (Ka-밴드 Fin-line 필터의 설계 및 제작에 관한 연구)

  • 유기한;이용만;최진일;박종화;강준길;나극환
    • Journal of Broadcast Engineering
    • /
    • v.3 no.1
    • /
    • pp.93-99
    • /
    • 1998
  • 본 논문에서는 Ka-밴드 위성통신 송신주파수대역(30.085∼30.885 GHz)의 대역통과 필터를 유도성 fin-line 구조를 이용하여 분석, 설계 및 제작하였다. 도파관내의 공진기들이 전계면에 수직한 금속 fin으로 구성된 구조를 해석하는데 가장 적합한 모드정합법을 사용하여 설계하였다. 제작된 필터는 마이크로파대역 뿐만 아니라 밀리미터파대역의 주파수에서도 우수한 필터특성을 갖는다는 특징을 가지고 있으며, 상업용 도파관을 사용하는 대신에 가격이 저렴하고 가공이 용이한 알루미늄을 사용함으로써 대량생산이 가능하다. 또한 도파관내 금속삽입형태에 의한 대역 통과 필터의 구현이 아닌 유한한 두께를 갖는 포토-에칭된 유전체 기판을 삽입함으로써 제작성의 어려움을 해결하였다. 설계, 제작된 필터의 측정결과 통과대역내에서 1.6dBal만의 삽입손실과 18dB이상의 반사손실을 갖는 응답특성을 얻었으며 이론에 의한 계산치와 측정치와의 비교를 통해 본 논문에서 제안된 설계방법의 타당성을 입증하였다.

  • PDF

Characterization of ZnO:Ga Films with Ag Insertion Layer

  • Kim, Min-Yeong;Son, Gyeong-Tae;Kim, Jong-Wan;Kim, Gi-Rim;Im, Dong-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.316-316
    • /
    • 2013
  • GZO/Ag/GZO 다층 투명 전도막은 투명 산화물 전극 사이에 빛이 투과할 수 있는 수준의 매우 얇은 금속을 삽입하여 낮은 면저항과 높은 투과율을 구현하는 기술로 금속의 유연성과 낮은 비저항, 산화물은 높은 투과도와 안정성을 동시에 이용할 수 있는 투명전도막이다. 본 연구에서는 RF 마그네트론 스퍼터와 전자빔 증착을 이용하여 GZO 박막 사이에 Ag 박막을 삽입한 GZO/Ag/GZO 구조의 박막을 제작하였다. Ag 박막의 두께와 공정 압력이 박막에 미치는 영향을 연구하였으며, 급속 열처리에 따른 GZO/Ag/GZO 박막의 특성을 분석하였다. Ag 삽입 박막 두께와 GZO/Ag/GZO 박막의 열처리 온도 최적화를 통하여 $2.2{\times}10-5{\Omega}{\cdot}cm$의 가장 낮은 비저항과 88.9%의 투과율을 나타내었다.

  • PDF

전기폭발법에 의해 제조되는 금속나노분말의 크기분포 실시간 측정

  • Lee, Seung-Bok;Bae, Gwi-Nam;Im, Seong-Sun;Lee, Dong-Jin;Park, Jung-Hak
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.58.2-58.2
    • /
    • 2009
  • 금속 와이어를 전기폭발법에 의해 증기 상태로 만든 후 응축시킬 때 제조되는 금속나노분말의 크기특성을 파악하기 위하여 제조장치에 샘플링 포트를 삽입하여 실시간 입자 측정기(Scanning Mobility Particle Sizer; SMPS) 로 14~615 nm 범위의 크기분포를 측정하였다. SMPS는 입자의 크기에 따라 전기적 이동도가 달라지는 원리를 이용하여 공기 중에 부유된 나노입자의 크기분포를 수 분내에 측정하는 실시간 입자 측정기이다. 금속나노분말 제조장치 내부는 약 0.5 bar 수준으로 불활성가스로 채워져 있어서 대기압보다 높은 고압조건이므로 SMPS 전단에 작은 노즐이 삽입된 pressure reducer를 부착하여 적정한 압력 수준으로 낮춘 후 SMPS로 나노분말의 크기분포를 실시간으로 측정하였다. 제조공정이 진행되면서 전기폭발이 주기적으로 발생하는 동안에 SMPS로 측정한 14~615 nm 범위 입자의 총 수농도는 약 $10^7$ 개/$cm^3$ 수준으로 매우 높았고, 약 100 nm와 200 nm에서 고농도 피크를 나타내는 bimodal 분포를 나타냈다. 반면 전기폭발이 잠시 중단되는 경우 입자의 총 수 농도는 약 $10^4$ 개/$cm^3$ 수준으로 낮아지고, 약 20 nm 이하의 입자가 대부분을 차지하면서 입자의 크기가 커질수록 농도가 낮아지는 형태의 크기분포로 바뀌었다. 본 연구를 통해 얻어진 제조장치 내부의 나노분말 크기분포 자료는 고품질 제품을 생산하기 위해 나노분말의 크기분포를 제어하는 분급장치 개발에 활용될 수 있을 것으로 기대된다.

  • PDF