• 제목/요약/키워드: 삽입

Search Result 6,824, Processing Time 0.036 seconds

THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD (CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구)

  • Row, Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.17-32
    • /
    • 1996
  • It is important to understand the operating mechanism and force system of fixed appliance that most effective for individual tooth movement in various orthodontic appliances. The archwire system of fixed appliance is devided into 3 types, which is continuous arch, segmented arch and sectional arch. The last two types have longer interbracket distance and simple force operating points, so it is easy to control force system by operator. But the continuous arch has shorter interbracket distance and various bracket geometry, so it is hard to control and anaylze the force system. The purpose of this study was three dimentional force and moment analysis of continuous arch system by finite element method, which is similar situation to three dimentional elastic beam in structural engineering. Several sample form of various bracket geometry and artificial lower crowding typodont made by author were constructed, analyzed and compared each other. The results were as follows : 1. The force magnitude is linear proportional to the degree of displacement or tilting of the bracket. 2. The force magnitude is inversely non-linear proportional to the interbracket distance. 3. In three dimensional typodont model, while the force can be compared with that of the sample form in the area where adjacent bracket geometry is simple, the force is much more than the expected value in the area where adjacent bracket geometry is complex.

  • PDF

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.

Clinical Features of Isolated Noncompaction of the Ventricular Myocardium (심근의 단독 비경화증(Isolated Noncompaction of Ventricular Myocardium)의 임상 양상)

  • Moon, Eun-Kyoung;Lee, Hoon-Young;Chang, Mea-Young;Kil, Hong-Ryang;Chung, Yong-Hun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1528-1533
    • /
    • 2002
  • Purpose : Isolated noncompaction of the ventricular myocardium(INVM) is one of the unclassified cardiomyopathies that is characterized by numerous, excessively prominent trabeculations, and deep intertrabecular recesses. We performed this study to evaluate the clinical features of INVM in children. Methods : The medical records of 10 patients with INVM were reviewed. We analyzed the clinical manifestations, hemodynamics, pattern of inheritance, and long-term prognosis of INVM in children. Results : Age at diagnosis was $45{\pm}53months$(1 day-14 years) with follow-up lasting as long as 78 months. Most INVM was asymptomatic on diagnosis. Associated cardiac anomalies were noted in six patients(ventricualr or atrial septal defect, patent ductus arteriosus with mitral valve prolapse, or mitral valve cleft). Depressed or flat changes of T wave in lead II, III and aVF were observed on electrocardiography. Various arrhythmia including WPW syndrome with paroxysmal supraventricular tachycardia, third-degree atrioventricular block, and familial sick sinus node dysfuction were observed. The degree of trabeculation in INVM was significantly prominent from level of mitral valve to apex compared to age-matched control. Familial recurrences were noted in two patients. The systolic function of the left ventricle was decreased in 20% of patients during the follow-up period, but systemic embolism or ventricular tachycardia was not observed. Conclusion : INVM is not a rare disorder. The cardiac function may be deteriorated in children as well as adults during long-term follow up. Thus early diagnosis and long-term follow-up must be done. So, the nation-wide multicenter clinical study would be mandatory to evaluate the incidence, long-term prognosis, and establishment of objective diagnostic criteria of INVM.

Why Central Banks Intervene? (왜 중앙은행은 개입하는가?)

  • Ko, Jong-Moon
    • The Korean Journal of Financial Management
    • /
    • v.12 no.2
    • /
    • pp.273-298
    • /
    • 1995
  • 1960년대, 각국의 환율이 미국의 달러화에 연동(pegging)된 고정환율제도를 근간으로 하는 브레튼우즈(Bretton Woods)체제하에서 각국의 중앙은행은 환율을 일정한 범위 내로 유지하기 위한 정책수단으로 외환시장개입을 적극 활용하였다. 1973년 브레튼우즈체제하의 고정환율제도가 붕괴되고 변동환율제도가 채택된 이후에도 각국의 외환시장개입정책은 계속되었다. 1980년대에 레이건 행정부의 재정팽창정책과 미연방준비은행의 긴축통화정책으로 금리의 지속적인 상승과 미달러화의 큰폭의 절상이 이루어 졌다. 이에 국제무역의 위기를 우려한 미국, 독일, 프랑스, 영국, 일본 등 선진 5개국(Group-5, G5)은 1985년 9월 22일 미 달러화의 절하를 위해 외환시장에 공동으로 개입할 것을 주내용으로 한 플라자합의(Plaza Agreement)를 발표하였다. 그후에도 1987년 2월 23일 열린 루브르협정(Louvre Accord, G-6 Communique)에서 환율을 현수준으로 유지시키기 위한 목표환율대(Target zone)를 설정하고 외환시장개입을 통해 이를 유지하기로 합의한 바 있다. 이후의 구미각국은 환율의 관리를 위하여 국가가 공동으로 외환시장에 개입하곤 했다. 본 논문은 1987년 루브르협정 이후 미국, 독일 및 일본의 중앙은행의 외환시장 개입 정책이 소기의 목적을 달성했는지의 여부를 규명해 보고자 한다. 즉, Federal Reserve, Bundesbank 및 Bank of Japan의 외환시장개입이 현물환율시장(spot market)에서 각각의 변동성을 감소 시켰는지의 여부를 독일의 마르크화 및 일본의 엔화를 중심으로 규명해 보고자 한다. 1981년 루브르협정이후, 미국, 독일 및 일본의 중앙은행은 미국 달러화에 대한 마르크 및 엔화의 환율을 안정시키기 위해 꾸준히 외환시장에 개입해 왔다. 외환시장의 개입유형은 크게 태화외환시장개입(non-sterilized intervention)과 불태화외환시장개입(sterilized intervention)으로 구분할 수 있는데, 전자는 외환당국이 민간부문과 외화채권을 거래함으로써 본원통화의 크기가 변하는 개입형태를 의미하는 반면에 후자는 외환당국의 순외화자산의 크기변화가 본원통화의 변화를 초래하지 않는 경우이다. 즉, 불태화외환시장개입은 순외화자산의 증감이 순국내자산의 증감과 반비례해서 이루어지기 때문에 본원통화의 크기에는 변함이 없다. 외환시장개입이란 외환당국이 은행간 시장에서 민간시잔 참가자들과 행하는 적극적인 외환거래를 의미한다. 반면, 넓은 의미에서의 외환시장개입에는 수동적 외환시장개입이라고 불리는 고객거래가 포함된다. 후자의 거래는 국내통화 및 외화표시 자산의 상대적 공급규모를 변화시킨다는 의미에서 전통적외환시장개입과 동일한 효과를 갖기 때문에 광의의 외환시장 개입으로 분류된다. 외환시장의 개입목적은 크게 세 가지로 분류할 수 있다. 첫째, 환율의 안정적 운영이다. 환율수준이 자유롭게 변화되는 변동환율제도하에서 환율의 지나친 변동으로 인한 실물경제로의 부정적인 영향을 최소화하기 위해서 환율의 지나친 변동으로 인한 실물경제로의 부정적인 영향을 최소화하기 위해서 환율의 안정을 정책 목표로 설정하는 경우와 고정환율제도하에서 환율을 일정수준으로 유지시키기 위해서 외환당국이 외환시장에 개입하는 경우가 여기에 해당된다고 볼 수 있다. 둘째, 환율수준의 균형수준으로의 조정이다. 이때 야기될 수 있는 문제점으로는 환율균형 수준을 어떻게 정의, 추정할 것이냐 하는 점과 목표환율정책이 다른 정책목표와 상충될 수 있다는 점이다. 셋째, 외환당국이 공적외환보유액이나 구성을 변화시킬 목적으로 외환시장에 개입하는 경우이다. 이때의 외환시장개입은 현재의 환율수준이 개입으로 인하여 과도하게 이탈하는 문제가 발생하지 않을 것을 전제로 한다. 본고에서는 현물환율에 영향을 미치는 요소로 미국, 독일 및 일본의 중앙은행의 개입효과, 요일효과, 통화의 공급량(M1), 무역적자의 폭, 산업의 생산량, 생산가격지수(PPI), 소비자물가지수(CPI), 실업률, 옵션의 내재적 변동성 등을 고려한다. 환율의 변동성을 추정하는 식은 GARCH 모델이 사용된다. 본 추정모델은 Dominguez(1993)의 확장이다. Dominguez (1993)의 논문은 GARCH 모델을 써서 미국, 독일 및 일본의 중앙은행의 시장개입효과를 분석했으나, 거시변수를 고려대상에서 제외시켰다. 본 논문은 위의 방법에 거시변수를 삽입하고 모델을 변형시켜서 더 확실한 시장개입효과와 거시변수효과를 밝혔다. 또한 옵션의 내제적 변동성을 구하는 과정에서 American option model을 사용하는 대신, Bourtha & Courtadon (1987)등이 밝힌 바와 같이 American style option이라 할지라도, European Model을 쓰면 더욱더 간편하고, 예측력도 American Model에 뒤지지 않음을 이용하여, European Model을 써서 내재적 변동성을 구한 다음 이것을 독립변수로 이용하였다. 본 모델의 추정 결과는 3국의 시장개입정책이 현물환율과 옵션의 내재적 변동성을 증가시켜서 Louvre 협정이후 각국은 시장개입의 목적을 달성하지 못한 것으로 나타났다.

  • PDF

Effects of Web-Based Nutrition Counseling on Nutrient Intake and Blood Glucose in Type II Diabetic Patients (제 2형 당뇨병 환자의 영양섭취 및 혈당에 웹기반 영양상담이 미치는 영향)

  • Park, Sun-Young;Han, Ji-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.9
    • /
    • pp.1398-1406
    • /
    • 2005
  • The purpose of this study was to investigate effects of web-based nutrition counseling on nutrient intake and blood glucose in type ll diabetic Patients. Forty type II diabetic patients, twenty one of them were diabetic patients without complication (Ncx-DM) and nineteen of them were diabetic patients with complication (Cx-DM), participated in a web-based nutrition counseling program. At the first nutrition counseling, the patients were counselled through interview and then follow up nutrition counseling was accomplished four times during eight weeks through tile web-based internet program. Various markers of disease risk including anthropometric indices, nutrient intake and blood glucose were measured before and after the nutrition counseling. After the nutrition counseling, body mass index and waist circumference decreased in both group but did not change significantly. Fasting blood glucose significantly decreased from 153.9 mg/dL to 139.0 mg/dL (p<0.05) in NCX-DM and from 178.2 mg/dL to 128.5 mg/dL (p<0.01) in Cx-DM after the nutrition counseling. Glycosylated hemoglobin level decreased from $9.3\%$ to $8,7\%$ in Ncx-DM and significantly decreased from $9.7\%$ to $7.8\%$ (p<0.01) in Cx-DM after the nutrition counseling. In addition, total cholesterol and LDL-cholesterol level significantly decreased in both group (P<0,05) after the nutrition counseling. Energy intake decreased significantly in Ncx-DM (P<0.05) and Cx-DM (p<0.01). Although the nutrient intake did not change significantly, the nutrient intake was improved after the nutrition counseling. Therefore, this study shows that the web-based nutrition counseling is effective in improving energy and nutrient intake and influences positively in blood glucose and serum lipids of the patients. In addition, these results indicate that the internet presents us with potential as a new medium for nutrition counseling in informationized society.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Accuracy Evaluation of Tumor Therapy during Respiratory Gated Radiation Therapy (호흡동조방사선 치료 시 종양 치료의 정확도 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chol-Soo;Kang, Se-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.113-122
    • /
    • 2010
  • Purpose: To evaluate the accuracy of a target position at static and dynamic state by using Dynamic phantom for the difference between tumor's actual movement during respiratory gated radiation therapy and skin movement measured by RPM (Real-time Position Management). Materials and Methods: It self-produced Dynamic phantom that moves two-dimensionally to measure a tumor moved by breath. After putting marker block on dynamic phantom, it analyzed the amplitude and status change depending on respiratory time setup in advance by using RPM. It places marker block on dynamic phantom based on this result, inserts Gafchromic EBT film into the target, and investigates 5 Gy respectively at static and dynamic state. And it scanned investigated Gafchromic EBT film and analyzed dose distribution by using automatic calculation. Results: As a result of an analysis of Gafchromic EBT film's radiation amount at static and dynamic state, it could be known that dose distribution involving 90% is distributed within margin of error of 3 mm. Conclusion: As a result of an analysis of dose distribution's change depending on patient's respiratory cycle during respiratory gated radiation therapy, it is expected that the treatment would be possible within recommended margin of error at ICRP 60.

  • PDF