• Title/Summary/Keyword: 삽입력

Search Result 340, Processing Time 0.025 seconds

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Why Central Banks Intervene? (왜 중앙은행은 개입하는가?)

  • Ko, Jong-Moon
    • The Korean Journal of Financial Management
    • /
    • v.12 no.2
    • /
    • pp.273-298
    • /
    • 1995
  • 1960년대, 각국의 환율이 미국의 달러화에 연동(pegging)된 고정환율제도를 근간으로 하는 브레튼우즈(Bretton Woods)체제하에서 각국의 중앙은행은 환율을 일정한 범위 내로 유지하기 위한 정책수단으로 외환시장개입을 적극 활용하였다. 1973년 브레튼우즈체제하의 고정환율제도가 붕괴되고 변동환율제도가 채택된 이후에도 각국의 외환시장개입정책은 계속되었다. 1980년대에 레이건 행정부의 재정팽창정책과 미연방준비은행의 긴축통화정책으로 금리의 지속적인 상승과 미달러화의 큰폭의 절상이 이루어 졌다. 이에 국제무역의 위기를 우려한 미국, 독일, 프랑스, 영국, 일본 등 선진 5개국(Group-5, G5)은 1985년 9월 22일 미 달러화의 절하를 위해 외환시장에 공동으로 개입할 것을 주내용으로 한 플라자합의(Plaza Agreement)를 발표하였다. 그후에도 1987년 2월 23일 열린 루브르협정(Louvre Accord, G-6 Communique)에서 환율을 현수준으로 유지시키기 위한 목표환율대(Target zone)를 설정하고 외환시장개입을 통해 이를 유지하기로 합의한 바 있다. 이후의 구미각국은 환율의 관리를 위하여 국가가 공동으로 외환시장에 개입하곤 했다. 본 논문은 1987년 루브르협정 이후 미국, 독일 및 일본의 중앙은행의 외환시장 개입 정책이 소기의 목적을 달성했는지의 여부를 규명해 보고자 한다. 즉, Federal Reserve, Bundesbank 및 Bank of Japan의 외환시장개입이 현물환율시장(spot market)에서 각각의 변동성을 감소 시켰는지의 여부를 독일의 마르크화 및 일본의 엔화를 중심으로 규명해 보고자 한다. 1981년 루브르협정이후, 미국, 독일 및 일본의 중앙은행은 미국 달러화에 대한 마르크 및 엔화의 환율을 안정시키기 위해 꾸준히 외환시장에 개입해 왔다. 외환시장의 개입유형은 크게 태화외환시장개입(non-sterilized intervention)과 불태화외환시장개입(sterilized intervention)으로 구분할 수 있는데, 전자는 외환당국이 민간부문과 외화채권을 거래함으로써 본원통화의 크기가 변하는 개입형태를 의미하는 반면에 후자는 외환당국의 순외화자산의 크기변화가 본원통화의 변화를 초래하지 않는 경우이다. 즉, 불태화외환시장개입은 순외화자산의 증감이 순국내자산의 증감과 반비례해서 이루어지기 때문에 본원통화의 크기에는 변함이 없다. 외환시장개입이란 외환당국이 은행간 시장에서 민간시잔 참가자들과 행하는 적극적인 외환거래를 의미한다. 반면, 넓은 의미에서의 외환시장개입에는 수동적 외환시장개입이라고 불리는 고객거래가 포함된다. 후자의 거래는 국내통화 및 외화표시 자산의 상대적 공급규모를 변화시킨다는 의미에서 전통적외환시장개입과 동일한 효과를 갖기 때문에 광의의 외환시장 개입으로 분류된다. 외환시장의 개입목적은 크게 세 가지로 분류할 수 있다. 첫째, 환율의 안정적 운영이다. 환율수준이 자유롭게 변화되는 변동환율제도하에서 환율의 지나친 변동으로 인한 실물경제로의 부정적인 영향을 최소화하기 위해서 환율의 지나친 변동으로 인한 실물경제로의 부정적인 영향을 최소화하기 위해서 환율의 안정을 정책 목표로 설정하는 경우와 고정환율제도하에서 환율을 일정수준으로 유지시키기 위해서 외환당국이 외환시장에 개입하는 경우가 여기에 해당된다고 볼 수 있다. 둘째, 환율수준의 균형수준으로의 조정이다. 이때 야기될 수 있는 문제점으로는 환율균형 수준을 어떻게 정의, 추정할 것이냐 하는 점과 목표환율정책이 다른 정책목표와 상충될 수 있다는 점이다. 셋째, 외환당국이 공적외환보유액이나 구성을 변화시킬 목적으로 외환시장에 개입하는 경우이다. 이때의 외환시장개입은 현재의 환율수준이 개입으로 인하여 과도하게 이탈하는 문제가 발생하지 않을 것을 전제로 한다. 본고에서는 현물환율에 영향을 미치는 요소로 미국, 독일 및 일본의 중앙은행의 개입효과, 요일효과, 통화의 공급량(M1), 무역적자의 폭, 산업의 생산량, 생산가격지수(PPI), 소비자물가지수(CPI), 실업률, 옵션의 내재적 변동성 등을 고려한다. 환율의 변동성을 추정하는 식은 GARCH 모델이 사용된다. 본 추정모델은 Dominguez(1993)의 확장이다. Dominguez (1993)의 논문은 GARCH 모델을 써서 미국, 독일 및 일본의 중앙은행의 시장개입효과를 분석했으나, 거시변수를 고려대상에서 제외시켰다. 본 논문은 위의 방법에 거시변수를 삽입하고 모델을 변형시켜서 더 확실한 시장개입효과와 거시변수효과를 밝혔다. 또한 옵션의 내제적 변동성을 구하는 과정에서 American option model을 사용하는 대신, Bourtha & Courtadon (1987)등이 밝힌 바와 같이 American style option이라 할지라도, European Model을 쓰면 더욱더 간편하고, 예측력도 American Model에 뒤지지 않음을 이용하여, European Model을 써서 내재적 변동성을 구한 다음 이것을 독립변수로 이용하였다. 본 모델의 추정 결과는 3국의 시장개입정책이 현물환율과 옵션의 내재적 변동성을 증가시켜서 Louvre 협정이후 각국은 시장개입의 목적을 달성하지 못한 것으로 나타났다.

  • PDF

Analysis of Magnetic Isotropy Property using Magnetoresistance Curve of CoFe/Cu/CoFe/PtMn Multilayer Film (CoFe/Cu/CoFe/PtMn 다층박막의 자기저항 곡선을 이용한 자기 등방성 특성 분석)

  • Choi, Jong-Gu;Kim, Su-Hee;Choi, Sang-Heon;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.123-128
    • /
    • 2017
  • The magnetic isotropy property from the magnetoresistance (MR) curve and magnetization (MH) loop for the PtMn based spin valve (SV) multilayer films fabricated with different the bottom structure after post-annealing treatment was investigated. The exchange biased coupling field ($H_{ex}$), coercivity ($H_c$), and MR ratio of Glass/Ta(10 nm)/CoFe(6 nm)/Cu(2.5 nm)/CoFe(3 nm)/Ta(4 nm) SV multilayer film without antiferromagnetic PtMn layer are 0 Oe, 25 Oe, and 3.3 %, respectively. MR curve for the Glass/Ta(10 nm)/CoFe(6 nm)/Cu(2.5 nm)/CoFe(3 nm)/PtMn(6 nm)/Ta(4 nm) SV multilayer film showed $H_{ex}=2Oe$, $H_c=316Oe$, and MR (%) = 4.4 % with one butterfly MR curve having by the effect of antiferromagnetic PtMn layer. MR curve for the dualtype Glass/Ta(10 nm)/CoFe(6 nm)/Cu(2.5 nm)/CoFe(3 nm)/PtMn(6 nm)/CoFe(3 nm)/Cu(2.5 nm)/CoFe(6 nm)/Ta(4 nm) SV multilayer film showed $H_c=37.5Oe$ and 386 Oe, MR = 3.5 % and 6.5 % with two butterfly MR curves and square-like hysteresis MH loops. The anisotropy property in CoFe spin valve-PtMn multilayer is neglected by the effects of a very small value of $H_{ex}$ and a very slightly shape magnetic anisotropy. This result is possible to explain the effect of magnetization configuration spin array of the bottom SV film and the top SV film of PtMn layer.

Athermalization and Narcissus Analysis of Mid-IR Dual-FOV IR Optics (이중 시야 중적외선 광학계 비열화·나르시서스 분석)

  • Jeong, Do Hwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.110-118
    • /
    • 2018
  • We have designed a mid-infrared optical system for an airborne electro-optical targeting system. The mid-IR optical system is a dual-field-of-view (FOV) optics for an airborne electro-optical targeting system. The optics consists of a beam-reducer, a zoom lens group, a relay lens group, a cold stop conjugation optics, and an IR detector. The IR detector is an f/5.3 cooled detector with a resolution of $1280{\times}1024$ square pixels, with a pixel size of $15{\times}15{\mu}m$. The optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ and $5.40^{\circ}{\times}4.23^{\circ}$) by the insertion of two lenses into the zoom lens group. The IR optical system was designed in such a way that the working f-number (f/5.3) of the cold stop internally provided by the IR detector is maintained over the entire FOV when changing the zoom. We performed two analyses to investigate thermal effects on the image quality: athermalization analysis and Narcissus analysis. Athermalization analysis investigated the image focus shift and residual high-order wavefront aberrations as the working temperature changes from $-55^{\circ}C$ to $50^{\circ}C$. We first identified the best compensator for the thermal focus drift, using the Zernike polynomial decomposition method. With the selected compensator, the optics was shown to maintain the on-axis MTF at the Nyquist frequency of the detector over 10%, throughout the temperature range. Narcissus analysis investigated the existence of the thermal ghost images of the cold detector formed by the optics itself, which is quantified by the Narcissus Induced Temperature Difference (NITD). The reported design was shown to have an NITD of less than $1.5^{\circ}C$.

Polymorphisms and Allele Distribution of Novel Indel Markers in Jeju Black Cattle, Hanwoo and Imported Cattle Breeds (제주흑우, 한우 및 수입 소 품종에서 새로운 indel 마커의 다형성과 대립인자 분포)

  • Han, Sang-Hyun;Kim, Jae-Hwan;Cho, In-Cheol;Cho, Sang-Rae;Cho, Won-Mo;Kim, Sang-Geum;Kim, Yoo-Kyung;Kang, Yong-Jun;Park, Yong-Sang;Kim, Young-Hoon;Park, Se-Phil;Kim, Eun-Young;Lee, Sung-Soo;Ko, Moon-Suck
    • Journal of Life Science
    • /
    • v.22 no.12
    • /
    • pp.1644-1650
    • /
    • 2012
  • The aim of this study was to screen the polymorphisms and distribution of each genotype of insertion/ deletion (indel) markers which were found in a preliminary comparative study of bovine genomic sequence databases. Comparative bioinformatic analyses were first performed between the nucleotide sequences of Bovine Genome Project and those of expressed sequence tag (EST) database, and a total of fifty-one species of indel markers were screened. Of these, forty-two indel markers were evaluated, and nine informative indel markers were ultimately selected for population analysis. Nucleotide sequences of each marker were re-sequenced and their polymorphic patterns were typed in six cattle breeds: Holstein, Angus, Charolais, Hereford, and two Korean native cattle breeds (Hanwoo and Jeju Black cattle). Cattle breeds tested in this study showed polymorphic patterns in eight indel markers but not in the Indel-15 marker in Charolais and Holstein. The results of analysis for Jeju Black cattle (JBC) population indicated an observed heterozygosity (Ho) that was highest in HW_G1 (0.600) and the lowest in Indel_29 (0.274). The PIC value was the highest in HW_G4 (0.373) and lowest in Indel_6 (0.305). These polymorphic indel markers will be useful in supplying genetic information for parentage tests and traceability and to develop a molecular breeding system for improvement of animal production in cattle breeds as well as in the JBC population.

The Effects of Water Extract of Polygonatum Odoratum (Mill) Druce on Insulin Resistance in 90% Pancreatectomized Rats (90% 췌장 절제 백서에서 둥굴레뿌리의 물추출물이 인슐린 저항성에 미치는 영향)

  • Park, Sun-Min;Ahn, Seung-Hee;Choi, Mi-Kyung;Choi, Soo-Ran;Choi, Soo-Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.619-625
    • /
    • 2001
  • We determined whether the supplementation of Polygonatum Odoratum (Mill) Druce (POD) extract had a good effect on insulin resistance in peripheral tissues of 90% pancreatectomized (Px) and sham-operated (Sham) male Sprague Dawley rats. Px and Sham rats were divided into two groups; one group daily consumed 0.3 g of POD extracts per 1 ㎏ body weight for two months, and the other group had a placebo. All rats freely consumed a 40% fat diet. At the end of the experiment, a euglycemic hyperinsulinemic (EH) clamp was performed in a fasting, awake, and unstressed state to determine insulin resistance. At EH clamp, body weights were higher in Sham rats than Px rats, and serum glucose levels of baseline were affected by diabetic status and POD administration. Serum insulin concentrations were higher in Sham rats than Px rats, and POD administration decreased them in Sham rats compared to P. Glucose disposal rates in peripheral tissues increased with POD in both Px (n=10) and Sham (n=10) rats. But glycogen deposits in soleus muscle increased with POD administration in Px and Sham rats, and total glycogen synthase activity and fraction velocity were higher in POD groups. Triglyceride contents in quadriceps muscles decreased with POD in Px rats. In conclusions, POD improves insulin resistance by enhancing glucose utilization with increasing glycogen deposit and decreasing triglyceride contents in muscles.

  • PDF

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Design of a Dual Band-pass Filter Using Fork-type Open Stubs and SIR Structure (포크 형태의 개방형 스터브 및 SIR 구조를 이용한 이중대역 대역통과 여파기의 설계)

  • Tae-Hyeon Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.1
    • /
    • pp.252-264
    • /
    • 2023
  • This paper proposes a design of a dual-band band-pass filter that integrates a λg/2 open SIR structure, a transmission line, and a fork-type structure with symmetric and asymmetric open stubs. To obtain the dual-band effect, the proposed filter uses the SIR structure and adjusts the impedance ratio of the SIR structure. Therefore, the position of the harmonics of the filter is shifted through the adjustment of the impedance ratio, and this can obtain a double-band effect. In order to obtain the dual-band characteristics, the dual-band effect is obtained by inserting a open stub between the SIR structures with the SIR structure divided in half. In addition, the second frequency response is obtained by adjusting the length of the open symmetrical stub in the fork-shaped structure. The asymmetrical open stub in the fork form achieves optimum bandwidth by adjusting the length. Therefore, the first center frequency of the proposed band-pass filter is 5.896 GHz and the bandwidth is 13.6 %. At this time, the measurement results are 0.13 dB and 33.6 dB. The second center frequency is 5.906 GHz and the bandwidth is 13.6 %. At this time, the measurement results are 0.15 dB and 19.8 dB. The reason is that when the impedance ratio (Δ) is higher than 1, the position of the harmonic is shifted to a lower frequency band. However, if the impedance ratio (Δ) is lowered by one step, the position of harmonics will move to a higher frequency band. The function of the filter designed using these characteristics can be obtained from the measurement result. The proposed band-pass filter has no coupling loss and no via energy concentration loss because there is no coupling structure of input/output and no via hole. Therefore, system integration is possible due to its excellent performance, and it is expected that dedicated short-range communication (DSRC) system applications used in traffic communication systems will be possible.

Studies on the Functional Interrelation between the Vestibular Canals and the Extraocular Muscles (미로반규관(迷路半規管)과 외안근(外眼筋)의 기능적(機能的) 관계(關係)에 관(關)한 연구(硏究))

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.1-17
    • /
    • 1974
  • This experiment was designed to explore the specific functional interrelations between the vestibular semicircular canals and the extraocular muscles which may disclose the neural organization, connecting the vestibular canals and each ocular motor nuclei in the brain system, for vestibuloocular reflex mechanism. In urethane anesthetized rabbits, a fine wire insulated except the cut cross section of its tip was inserted into the canals closely to the ampullary receptor organs through the minute holes provided on the osseous canal wall for monopolar stimulation of each canal nerve. All extraocular muscles of both eyes were ligated and cut at their insertio, and the isometric tension and EMG responses of the extraocular muscles to the vestibular canal nerve stimulation were recorded by means of a physiographic recorder. Upon stimulation of the semicircular canal nerve, direction if the eye movement was also observed. The experimental results were as follows. 1) Single canal nerve stimulation with high frequency square waves (240 cps, 0. 1 msec) caused excitation of three extraocular muscles and inhibition of remaining three muscles in the bilateral eyes; stimulation of any canal nerve of a unilateral labyrinth caused excitation (contraction) of the superior rectus, superior oblique and medial rectus muscles and inhibition (relaxation) of the inferior rectus, inferior oblique and lateral rectos muscles in the ipsilateral eye, and it caused the opposite events in the contralateral eye. 2) By the overlapped stimulation of triple canal nerves of a unilateral labyrinth, unidirectional (excitatory or inhibitory) summation of the individual canal effects on a given extraocular muscles was demonstrated, and this indicates that three different canals of a unilateral vestibular system exert similar effect on a given extraocular muscles. 3) Based on the above experimental evidences, a simple rule by which one can define the vestibular excitatory and inhibitory input sources to all the extraocular muscles is proposed; the superior rectus, superior oblique and medial rectus muscles receive excitatory impulses from the ipsilateral vestibular canals, and the inferior rectus, inferior oblique and lateral rectus muscles from the contralateral canals; the opposite relationship applies for vestibular inhibitory impulses to the extraocular muscles. 4) According to the specific direction of the eye movements induced by the individual canal nerve stimulation, an extraocutar muscle exerting major role (a muscle of primary contraction) and two muscles of synergistic contraction could be differentiated in both eyes. 5) When these experimental results were compared to the well known observations of Cohen et al. (1964) made in the cats, extraocular muscles of primary contraction were the same but those of synergistic contraction were partially different. Moreover, the oblique muscle responses to each canal nerve excitation appeared to be all identical. However, the responnes of horizontal (medial and lateral) and vertical (superior and inferior) rectus muscles showed considerable differences. By critical analysis of these data, the author was able to locate theoretical contradictions in the observations of Cohen et al. but not in the author's results. 6) An attempt was also made to compare the functional observation of this experiment to the morphological findings of Carpenter and his associates obtained by degeneration experiments in the monkeys, and it was able to find some significant coincidence between there two works of different approach. In summary, the author has demonstrated that the well known observations of Cohen et al. on the vestibulo-ocular interrelation contain important experimental errors which can he proved by theoretical evaluation and substantiated by a series of experiments. Based on such experimental evidences, a new rule is proposed to define the interrelation between the vestibular canals and the extraocular muscles.

  • PDF