• Title/Summary/Keyword: 삼첨판막수술

Search Result 68, Processing Time 0.026 seconds

Surgical Rrepair of Ebsteins Anomaly with Ventricular Septal Defect in the Infant (영아에서 시행한 심실중격결손이 동반된 Ebsein's 기형의 삼첨판막 성형수술)

  • 유지훈;박표원;성기익;박계현;이영탁;전태국
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.890-893
    • /
    • 2002
  • Ebsteins anomaly is a rare congenital cardiac malformation that is the downward displacement of the septal and posterior leaflets of the tricuspid valve into the ventricular apex, aresulting in the formation of an atrialized portion of the right ventricle. In most patients, symptoms such as cyanosis and progressive heart failure occur during the adolescence or young adulthood. The associated anomalies include ventricular septal defect, transposition of the great arteries, and malformation of the mitral valve. An 8-months-old male with Ebsteins anomaly, ventricular septal defect, and duplication of the mitral valve orifice successfully underwent operation with VSD patch closure. Postoperatively, cardiac size was significantly reduced and tricuspid regurgitation was trivial in echocardiography He has been doing well without any cardiac medication during the 18 months follow up after operation.

Surgical Correction of Ebstein's Anomaly -11 cases- (Ebstein 기형의 외과적 치료 - 11례 -)

  • 이선희;김시훈;윤정섭;김치경;조건현;왕영필;곽문섭;김우찬
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1202-1206
    • /
    • 1996
  • Ebstein's anomaly is an unusual and a rare congenital cardiac malformation but characteristic abnormality of the development of the tricuspid valve, right atrium and ventricle. The characteristic findings are a displaced tricuspid valve with a septal leaflet spiralling into the right ventricle. The surgical correction is variable and are left unsolved problem in surgical treatment of anomaly. Between January 1988 & December 1995, we experienced 11 cases of Ebstein's anomaly and associated cardiac anomalies are ASD, PFO, ASD with VSD. The typically displaced tricuspid valve leaflet was found in all cases. In the NYHA functional classification, three were in class II, seven were in class III, and one was in class IV. Nine patients were operated by tricuspid annuloplasty & plication with Danielson's method and two patients were done by tricuspid valve replacement with plication, and in all cases associated anomaly was corrected. Postoperatively, five patients suffered from complication - low cardiac output syndrome, arrhythmia and wound infection. There was no operative mortality and the postoperative courses were relatively good conditions with more improvement of symptoms.

  • PDF

Bidirectional Cavopulmonary Shunt for Isolated Right Ventricular Endomyocardial Fibrosis (우심실에 생긴 심근내막섬유증에서 시행한 양 방향성 상대정맥-폐동맥 단락 수술)

  • 서영준;이덕헌;박남희;최세영;유영선
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.523-526
    • /
    • 2003
  • A 44-year-old man had been admitted for dyspnea on exertion and abdominal distension. The echocardiography revealed abnormal mass in right atrium and tricuspid valve stenosis with right ventricular obliteration. The operation was performed with mass removal, enlargement of tricuspid valve opening, and right ventricular endocardiectormy. And then, atrial septal defect was made due to inadequate right ventricular volume. The patient's symptom was improved and he discharged without events. The endomyocardial fibrosis was diagnosed with microscopic examination. Eighteen months later, the patient was readmitted due to aggravated dyspnea and cyanosis. The right ventricular obliteration was progressed and pulmonary blood flow was severely decreased in follow up echocardiography. Palliative bidirectional cave-pulmonary shunt was performed due to functional single ventricle. The dyspnea and cyanosis was markedly improved. Bidirectional cavo-pulmonary shunt for advanced and isolated right ventricular endomyocardial fibrosis provided effective palliation at early postoperative period, However, long-term follow up is mandatory.

The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

Repair of Posttraumatic Tricuspid Regurgitation Using Artificial Chordae and an Annuloplasty Ring (인공 건삭과 판막륜 성형술을 이용한 외상 후 삼첨판 부전증의 치료)

  • Son, Kuk-Hui;Son, Ho-Sung;Chung, Jae-Ho;Chung, Won-Jae;Sun, Kyung;Lee, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.489-491
    • /
    • 2008
  • A 52-year-old man was taken to the emergency room following a motor vehicle accident. An echocardiogram showed moderate to severe tricuspid regurgitation due to rupture of the anterior chordae. An operation to repair the tarumatic tricuspid regurgitation was recommended; however, the patient refused because he was asymptomatic. Two years later, he developed mild generalized edema and dyspnea. The echocardiogram revealed progressive severe tricuspid regurgitation and annular dilatation. We treated the tricuspid regurgitation successfully using artificial chordae and ring annuloplasty.

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Intermediate-term Result of Tricuspid Annuloplasty for Tricuspid Regurgitation Associated with Congenital Heart Disease in Adult (성인 선천성 심기형에 동반된 삼첨판막 폐쇄부전의 판막륜 성형술 후 중기성적)

  • Yun, Tae-Jin;Kim, Sang-Hwa;Lee, Jun-Wan;Park, Jeong-Jun;Song, Hyun;Lee, Jae-Won;Seo, Dong-Man;Song, Meong-Gun;Song, Jong-Min;Kang, Duck-Hyun;Song, Jae-Kwan;Jang, Wan-Sook;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.136-141
    • /
    • 2003
  • We assessed the intermediate-term result of tricuspid annuloplasty (TAP) for tricuspid valve regurgitation (TR) associated with congenital heart disease in adults. Risk factors for residual TR were also analysed. Material and Method: From August 1989 to June 2001, seventy three adult patients, 51 females and 22 males, underwent TAP for TR associated with various congenital heart disease. Their age ranged from 46 years to 73 years (mean:43). Associated heart anomalies were atrial septal defect (55), ventricular septal defect (6), partial anomalous pulmonary venous return (4) and others (8). Preoperative and post-operative TR velocities were 3.25 m/sec and 2.56 m/sec respectively, and the types of TAP were De Vega in 43, Kay in 18 and Ring annuloplasty in 12. Postoperative follow-up duration was 2,347 patient-month (mean: 32.6 months), and 134 two-dimensional echocardiographic examinations were done during this period. Residual TR greater than III/IV was considered as TAP failure. Result: TAP failure was observed in 7 patients (9.6%), and one patient among them underwent tricuspid valve replacement. Risk factors for TAP failure were diagnosis other than atrial septal defect (p=0.001), preoperative (p=0.038) and postoperative (p=0.028) high TR velocity. There was no statistical significance in terms of TAP methods. Conclusion: Careful evaluation of valve morphology and aggressive surgical intervention are mandatory for the repair of TR with preoperative or residual RV pressure overload.

Robotic Assisted Surgery in Adult Patient with Congenital Ventricular Septal Defect (내시경 수술 보조 로봇을 이용한 성인 심실중격결손 교정술)

  • Park, Il;Lee, Jong-Tae;Kim, Gun-Jik;Cho, Joon-Yong
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.931-933
    • /
    • 2006
  • Robotic assisted surgery in adult patient with congenital ventricular septal defect Since December in 2005, we have done minimally invasive surgeries in selected cases of mitral valve diseases, tricuspid valve diseases, atrial septal defects and atrial fibrillations with the $AESOP^{TM}$ robotic arm. We have had a better surgical view and skill, according to accumulation of the experience of this procedure. Recently, we performed robotic assisted surgery in a 47-year-old female with congenital perimembranous ventricular septal defect.