• Title/Summary/Keyword: 산화-환원전위

Search Result 263, Processing Time 0.029 seconds

A Study on the Oxidation Process for Regeneration of Ferric Chloride Etching Solution (염화철 에칭 용액 재생을 위한 산화공정에 대한 연구)

  • Kim, Dae-Weon;Park, Il-Jeong;Kim, Geon-Hong;Lee, Sang-Woo;Choi, Hee-Lack;Jung, Hang-Chul
    • Resources Recycling
    • /
    • v.26 no.2
    • /
    • pp.18-24
    • /
    • 2017
  • The $FeCl_3$ solution has been used as an etchant for etching of metal. It is necessary to reuse the etching solution because waste $FeCl_3$ etchant generated after use has provided environmental and economic problems. In this study, HCl was mixed with the $FeCl_2$ solution and then $H_2O_2$ was added into the mixed solution to oxidize the $Fe^{2+}$. During the oxidation process, oxidation-reduction potential (ORP) was measured and the relationship between ORP and oxidation ratio was investigated. As a result, this study found that the ORP was increased with increasing the concentration of HCl and $H_2O_2$, while the ORP is decreased with oxidation progress. Such a behavior was in good agreement with Nernst's equation. Also, the oxidation efficiency reached about 99% when a sufficient amount of HCl and $H_2O_2$ were added.

Protective Effect of Electrolyzed Reduced Water on the Paraquat-induced Oxidative Damage of Human Lymphocyte DNA (Paraquat에 의한 사람 임파구 DNA 손상에 대한 환원전리수의 보호효과)

  • Park, Eun-Ju;Ryoo, Kun-Kul;Lee, Yoon-Bae;Lee, Jong-Kwon;Lee, Mi-Young
    • Applied Biological Chemistry
    • /
    • v.48 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Electrolyzed reduced water (ERW), showing extremely negative oxidation-reduction potential, was used to investigate the effects of paraquat-induced damages on DNA from human lymphocyte. The effect of ERW on paraquat-induced oxidative DNA damage in human lymphocytes was evaluated by Comet assay (single-cell gel electrophoresis) quantified as percentage fluorescence in tail. Comet assay has been used widely to assess the level of the DNA damage in individual cells. Lymphocytes were oxidatively challenged with various concentrations of paraquat for 30 min at $37^{\circ}C$, and were then treated with electrolyzed reduced water for 30 min. The oxidative DNA damage by paraquat, as indicated by the fluorescent tail in DNA, increased in a dose-dependent manner. However, oxidative damage of the DNA was almost completely prevented upon treatment with electrolyzed reduced water.

Studies on the Electrochemical Properties for Rancidity of Linoleic Acid (리놀산의 산패에 대한 전기화학적 특성 연구)

  • 김우성;이송주
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.4
    • /
    • pp.360-364
    • /
    • 2000
  • We studied the degree of rancidity of linoleic acid for the electrochemical redox reaction in time course and the kinetic parameters. The current of the linoleic acid was increased and the potential was shifted to the positive potential when scan rates were faster. The redox reaction of the linoleic acid was proceeding to totally irreversible and diffusion controlled reaction. From these results, diffusion coefficient(D$\_$o/) of linoleic acid was observed to 2.61$\times$10$\^$-6/ ㎠/s in the 0.1 M TEAP/DMF electrolyte solution. Also, exchange rate constant(K$\^$o/) was observed to 9.79$\times$10$\^$-11/ cm/s. The leaving time in air condition was found to affect the rancidity. We predicted that the product was carbonyl compounds.

  • PDF

The Manganese Oxide which has Modified Electrochemically Affects in Oxygen Reduction Reaction (전기화학적으로 석출된 망간 산화물이 산소 환원 반응에 미치는 영향)

  • Park, Sung-Ho;Shin, Hyun-Soo;Kim, Jeong-Sik;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • This study is concerned the electrocatalytic generation of oxygen gas at electrochemically deposited manganese oxide electrode in KOH solution. Manganese oxide nanoparticles electrodeposited onto relatively substrate, e.g glassy carbon, Au, Ti electrode. MnOx is electrodeposited in nanorod structure which cover the overall surface of the substrate. The $\gamma$-MnOOH that is kind of manganese oxide species plays a significant role as a catalytic mediator, which promote 4-electron reduction process. Modified electrodes with electrodeposited manganese oxide structures resulted in significant decrease in the anodic polarization compared with the unmodified electrodes in alkaline media.

Biogeochemistry of Alkaline and Alkaline Earth Elements in the Surface Sediment of the Gamak Bay (가막만 표층퇴적물 중 알칼리 및 알칼리 토금속 원소의 생지화학적 특성)

  • Kim, Pyoung-Joong;Park, Soung-Yun;Kim, Sang-Su;Jang, Su-Jeong;Jeon, Sang-Baek;Ju, Jae-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • We measured various geochemical parameters, including the grain size, loss on ignition(LOI), total organic carbon(TOC), total nitrogen(TN), total sulfur(TS) and metallic elements, in surface sediment collected from 19 stations in Gamak Bay in April 2010 in order to understand the sedimentary types, the origin of organic matters, and the distribution patterns of alkali(Li, Na, K, Rb) and alkaline earth(Be, Mg, Ca, Sr, Ba) elements. The surface sediments were mainly composed of mud. The concentrations of Chlorophyll-a, TOC, TN, TS and LOI in sediment were the highest at the cultivation areas of fish and shellfish in the northern and southern parts of the bay. The redox potential(or oxidation-reduction potential) showed the positive value in the middle part of the bay, indicating that the surface sediment is under oxidized condition. The organic materials in sediment at almost all of stations were characterized by the autochthonous origin. Based on the overall distributions of metallic elements, it appears that the concentrations of alkali and alkaline earth elements except Ba in sediment are mainly influenced by the dilution effect of quartz. The concentrations of Sr and Ba are also dependent on the secondary factors such as the effect of calcium carbonate and the redox potential.

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

Electrochemical Reduction of Methylene Blue and the Effect of Surfactants and Poly-Electrolytes (Methylene Blue의 전기화학적 환원과 계면활성제 및 고분자 전해질의 영향)

  • Kim, Il-Kwang;Jeong, Seung-Il;Chun, Hyun-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.1
    • /
    • pp.57-65
    • /
    • 1995
  • The electrochemical reduction of methylene blue (MB) in 1.0${\times}$10-2 M KNO3 aqueous solution was investigated by direct current (DC), differential pulse (DP) polarography, cyclic voltammetry (CV) and controlled potential coulometry (CPC). The electrode reduction of melthylene blue was processed CE reaction mechanism by two electrons transfer at the first reversible wave (- 0.18 volts vs. Ag/AgCl). MB was strongly adsorbed on the stationary mercury electrode and the reduction product of conptrolled potential electrolysis was rapidly auto-oxidized in air to the original methylene blue. Upon the basis of interpretation of cyclic voltammogram with pH change, possible CE electrode reaction mechanism was suggested.

  • PDF

Effects of Bubble Discharge on pH and Oxidation/Reduction Potential Change by Non-Uniform Electric Field (불평등전계에 의한 기포방전이 수소이온농도와 산화환원전위변화에 미치는 영양)

  • 김진규;김광태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.77-82
    • /
    • 2003
  • In this paper, as the new type of multi-lines electrode which can formulate strong non-uniform electric field was installed in strong electrolytic water generator, shapes of pre-discharge in bubble and effects of bubble discharge on pH and oxidation/reduction potential change were intended to investigate. Consequently, as multi-lines electrode was installed in side of anode, pre-discharges generated from anode electrode could be observed. This pre-discharge was generated from differences of permittivities between bubble and water in strong non-uniform electric field. And ion concentration in electrolytic water generator was increased by dissolving of ions generated from bubble discharge. So, as generated high concentration ions were separated and assembled to each electrode and reaction of oxidation/reduction was increased, it was shown that strong electrolytic water could be generated.

Errors in Potentiometric End-Point of Redox Titrations Determined by Zero Second Derivative Method (산화환원 전위차적정에 있어 수치미분법으로 얻은 영 2 차미분 종말점의 오차)

  • Q. Won Choi;Kyong Ryul Kim
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.3
    • /
    • pp.128-132
    • /
    • 1978
  • The potentiometric end-point of redox titrations determined by nulling the second derivative of the titration curve by numerical differentiation method is analyzed by using an electronic digital computer. The error involved in the method is shown to be dependent on the location of the equivalence point in the titrant addition increment that encompasses the latter. The error increases as the equivalence point moves away from the mid-point of the increment toward a maximum value that is as great as a half of the increment. Therefore, when the numerical differentiation method is used to null the second derivative, the end-point should be compared with the steepest point of the titration curve or diluted titrant should be used in the vicinity of the end-point.

  • PDF

고온 용융염에 활용 가능한 Ag/AgCl 기준전극 제조 및 이를 이용한 Cd 액체음극에서의 란탄족 염화물의 순환 전압 전류 특성

  • 안병길;심준보;김응호;유재형
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.333-333
    • /
    • 2004
  • 고온의 용융염 매질에서 전해 정련 또는 전해제련에 의해 원하는 물질을 회수하기 위한 공정에 있어서 정확한 산화/환원 전위 측정 및 안정된 전위를 인가하기 위해서는 재현성과 내구성이 확보된 기준 전극이 필요하다. 용융염 매질에서 많이 사용되는 기준 전극은 Ag/AgCl 전극으로서 온도 사이클에 대한 전위의 히스테리시스가 작고 고온에서도 전위가 안정하다. Ag/AgCl 기준전극으로 pyrex 봉 하단부를 수 마이크론 두께의 pyrex 박막으로 제작된 것은 고온 용융염에 접촉시 열 충격, 전극류와 충돌에 의한 물리적 취약성 및 고온의 용융염에 의한 부식과 같은 단점이 있다.(중략)

  • PDF