• Title/Summary/Keyword: 산소 투과성

Search Result 268, Processing Time 0.028 seconds

Spectral Response of $TiO_{2}$/Se : Te Heterojunction for Color Sensor (컬러센서를 위한 $TiO_{2}$/Se : Te 이종접합의 스펙트럼 응답)

  • Woo, Jung-Ok;Park, Wug-Dong;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.101-108
    • /
    • 1993
  • $TiO_{2}$/Se : Te heterojunction for color sensor has been fabricated by RF reactive sputtering and thermal evaporation methods onto glass substrate. The optimum deposition condition of $TiO_{2}$ films was such that RF power was 120 W, substrate temperature was $100^{\circ}C$, oxygen concentration was 50%, working pressure was 50 mTorr for the $TiO_{2}$ film thickness of $1000{\AA}$. In this case, the optical transmittance of $TiO_{2}$ film at 550 nm-wavelength was 85%, resistivity was $2{\times}10^9{\Omega}{\cdot}cm$, refractive index was 2.3, and optical bandgap was 3.58 eV. The composition ratio of 0 to Ti by AES analysis was 1.7. When $TiO_{2}$ films were annealed at $400^{\circ}C$ for 30 min. in $O_{2}$ ambient, the optical transmittance of $TiO_{2}$ films at the wavelength range of $300{\sim}580$ nm was improved from 0 to 25%. When Se : Te films were annealed at $190^{\circ}C$ for 1 min., photosensitivity under illumination of 1000 lux was 0.75. The optical bandgap of Se : Te films was 1.7 eV. The structures of Se : Te films were the hexagonal with (100) and (110) orientation. The spectral response of a-Se was improved by the addition of Te, especially in the long wavelength region. The $TiO_{2}$/Se : Te heterojunction showed wide spectral response, and more improved one than that of a-Si film in the blue light region.

  • PDF

Extending the Shelf-life of Yukwa Using Secondary Packaging (이차포장을 통한 유과의 저장성 연장)

  • Jung, Jun-Jae;Lee, Keun-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.452-458
    • /
    • 2010
  • This study aimed at improving the packaging technology of Yukwa to improve the quality and extend the shelflife using secondary packaging. After packaging the Yukwa using an OPP film, P2, P3, and P4 packaging materials were applied secondarily. Various films including (1) P1: OPP (oriented polypropylene), (2) P2: P1+OPP/LLDPE (linear low density polyethylene), (3) P3: P1+PET (polyethylene terephthalate)/NY (nylon)/CPP (cast polypropylene) and (4) P4: P1+PET/AL (aluminum)/NY/CPP (P4) were used for packaging Yukwa. The experiment was conducted at $25^{\circ}C$ for 12 weeks. P1 showed the highest acid value score (1.26 mg KOH/g), and P3 had the highest peroxide value score (32.91 meq/kg) among all packaging groups. Nevertheless, these values did not exceed the guideline values of 2.0 g KOH/g and 40 meq/kg specified in the Korean food code. The overall color difference showed a tendency for decreasing Hunter 'L' values and increasing 'a' and 'b' values; however, no noticeable difference in the outer appearance was observed in any of the packaging treatments except in the P1 for greater than 10 weeks of storage. Some texture defects were observed in the Yukwa when the moisture contents dropped below 5%. The P4 packaging treatment had the lowest moisture permeability and showed the least rheological deterioration change, followed by P3 and P2. In conclusion, the use of a secondary packaging with less gas and moisture permeability was more effective for maintaining the quality and extending the shelf-life of Yukwa than other types of packaging material.

Effect of PLA2 Inhibitor Rutin on Endotoxin-Induced Acute Lung Injury (내독소로 유도된 급성폐손상에서 PLA2의 억제제인 Rutin의 효과)

  • Kim, Seong-Eun;Lee, Young-Man;Park, Won-Hark
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.31-42
    • /
    • 2004
  • Acute respiratory distress syndrome (ARDS) is a kind of acute lung injury characterized by inflammatory disruption of alveolar-capillary barrier and notorious for its high mortality. Neutrophils cause cell damage through the production of free radicals, inflammatory mediators, and proteases in ARDS. $PLA_2$ might serve a primary regulatory role in the activation of neutrophils. This present study was performed to elucidate the effect of rutin known as $PLA_2$ inhibitor on ARDS induced by endotoxin. Endotoxin had increased lung myeloperoxidase (MPO) activity, BAL (bronchoalveolar lavage) protein content, numbers of neutrophils in BALF (bronchoalveolar lavage fluid) compared with those of control rat (p<0.001). In addition, histological evidence of lung injury was correlated with neutrophil influx into alveolar space and cerrous perhydroxide granules were found in lining of endothelial cell, alveolar type I, II cells. In contrast, pretreated group of rutin had significantly decreased all of the parameters (p<0.001). These data suggest that inhibition of $PLA_2$ is one step approach that block the process of ARDS. Accordingly, we conclude that rutin can be used as the prophylactic agent for ARDS on the bases of these experimental results.

Inflammatory Reponse of the Lung to Hypothermia and Fluid Therapy after Hemorrhagic Shock in Rats (흰쥐에서 출혈성 쇼크 후 회복 시 저체온법 및 수액 치료에 따른 폐장의 염증성 변화)

  • Jang, Won-Chae;Beom, Min-Sun;Jeong, In-Seok;Hong, Young-Ju;Oh, Bong-Suk
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.879-890
    • /
    • 2006
  • Background: The dysfunction of multiple organs is found to be caused by reactive oxygen species as a major modulator of microvascular injury after hemorrhagic shock. Hemorrhagic shock, one of many causes inducing acute lung injury, is associated with increase in alveolocapillary permeability and characterized by edema, neutrophil infiltration, and hemorrhage in the interstitial and alveolar space. Aggressive and rapid fluid resuscitation potentially might increased the risk of pulmonary dysfunction by the interstitial edema. Therefore, in order to improve the pulmonary dysfunction induced by hemorrhagic shock, the present study was attempted to investigate how to reduce the inflammatory responses and edema in lung. Material and Method: Male Sprague-Dawley rats, weight 300 to 350 gm were anesthetized with ketamine(7 mg/kg) intramuscular Hemorrhagic Shock(HS) was induced by withdrawal of 3 mL/100 g over 10 min. through right jugular vein. Mean arterial pressure was then maintained at $35{\sim}40$ mmHg by further blood withdrawal. At 60 min. after HS, the shed blood and Ringer's solution or 5% albumin was infused to restore mean carotid arterial pressure over 80 mmHg. Rats were divided into three groups according to rectal temperature level($37^{\circ}C$[normothermia] vs $33^{\circ}C$[mild hypothermia]) and resuscitation fluid(lactate Ringer's solution vs 5% albumin solution). Group I consisted of rats with the normothermia and lactate Ringer's solution infusion. Group II consisted of rats with the systemic hypothermia and lactate Ringer's solution infusion. Group III consisted of rats with the systemic hypothermia and 5% albumin solution infusion. Hemodynamic parameters(heart rate, mean carotid arterial pressure), metabolism, and pulmonary tissue damage were observed for 4 hours. Result: In all experimental groups including 6 rats in group I, totally 26 rats were alive in 3rd stage. However, bleeding volume of group I in first stage was $3.2{\pm}0.5$ mL/100 g less than those of group II($3.9{\pm}0.8$ mL/100 g) and group III($4.1{\pm}0.7$ mL/100 g). Fluid volume infused in 2nd stage was $28.6{\pm}6.0$ mL(group I), $20.6{\pm}4.0$ mL(group II) and $14.7{\pm}2.7$ mL(group III), retrospectively in which there was statistically a significance between all groups(p<0.05). Plasma potassium level was markedly elevated in comparison with other groups(II and III), whereas glucose level was obviously reduced in 2nd stage of group I. Level of interleukine-8 in group I was obviously higher than that of group II or III(p<0.05). They were $1.834{\pm}437$ pg/mL(group I), $1,006{\pm}532$ pg/mL(group II), and $764{\pm}302$ pg/mL(group III), retrospectively. In histologic score, the score of group III($1.6{\pm}0.6$) was significantly lower than that of group I($2.8{\pm}1.2$)(p<0.05). Conclusion: In pressure-controlled hemorrhagic shock model, it is suggested that hypothermia might inhibit the direct damage of ischemic tissue through reduction of basic metabolic rate in shock state compared to normothermia. It seems that hypothermia should be benefit to recovery pulmonary function by reducing replaced fluid volume, inhibiting anti-inflammatory agent(IL-8) and leukocyte infiltration in state of ischemia-reperfusion injury. However, if is considered that other changes in pulmonary damage and inflammatory responses might induce by not only kinds of fluid solutions but also hypothermia, and that the detailed evaluation should be study.

Effect of Non-Perforated Breathable Films on the Storability of 'Fuji' Apples in Modified Atmosphere Condition in the Different Storage Temperature (비천공 Breathable필름이 몇 가지 저장온도에서 '후지' 사과의 MA 저장성에 미치는 영향)

  • Choi, In-Lee;Sung Mi, Hong;Min Jae, Jeong;Jun Pill, Baek;Ho-Min, Kang
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.60-64
    • /
    • 2014
  • These studies were conducted to identify the effects of non-perforated breathable package film on storability at $1^{\circ}C$, $8^{\circ}C$, and $20^{\circ}C$ storage of 'Fuji' apples. The fresh weight loss rate was less than 2.0% in all non-perforated breathable films at three different storage periods and temperatures, $1^{\circ}C$; 210 days, $8^{\circ}C$; 75 days, and $20^{\circ}C$; 30 days except for the perforated film. 1,300 cc ($1^{\circ}C$), 5,000 cc ($8^{\circ}C$), and 10,000 cc ($20^{\circ}C$) films were closed at the optimum MA storage condition by carbon dioxide and oxygen concentration. Ethylene concentration was lowest at the 40,000 cc film in every temperatures during storage. The 1,300 cc film established higher result in soluble solid and vitamin C content than any other films at $1^{\circ}C$, also showed higher in visual quality by panel test. The 5,000 cc film had the best results on soluble solid and off-flavor in $8^{\circ}C$. In the $20^{\circ}C$ storage after 30 days of treatment the 10,000 cc film had highest firmness and visual quality. Following these results, it come to conclusion the suitable type of non-perforated breathable film such as 1,300 cc at $1^{\circ}C$, 5,000 cc at $8^{\circ}C$, and 10,000 cc at $20^{\circ}C$ for MA storage in 'Fuji' apples.

Historical Investigation on Development of Produce and Packages or Physical Analysis of Packaging's Materials of Cheese in Korea since 1967-2 (1967년 이후 한국(韓國)에서 치즈제품(製品)의 개발(開發)과 포장(包裝)의 변화(變化) 및 그 포장재(包裝材)의 생물학적(生物學的) 조사연구(調査硏究)-2)

  • Kim, Duck-Woong
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.5 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Physical analysis of some composite films of outer packaging at process cheeses in Korea is as following. In comparison with four composite films, tensile strength is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;MD9.55kg/15mm,\;TD8.95kg/15mm>79.3{\mu}PET/PVDC/L-LDPE\;film\;MD5.37kg/15mm,\;TD5.01kg/15mm>96.9{\mu}PE/PVDC/PE\;film\;MD5.42kg/15mm,\;TD4.73kg/15mm>61.6{\mu}PVDC/PE/AL-vac/CPS\;film\;MD4.65kg/15mm,\;TD4.22kg/15mm$. Water vapor transmission is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;0.41g/m^2{\cdot}24hr>79.3{\mu}PET/PVDC/L-LDPE\;film\;3.77g/m^2{\cdot}24hr>96.9{\mu}PE/PVDC/PE\;film\;3.81g/m^2{\cdot}24hr>61.6{\mu}PVDC/PE/AL-vac/4.91g/m^2{\cdot}24hr$. Gas transmission $O_2:N_2:CO_2$ is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;1.81:0.74:4.2cc/m^2{\cdot}24hr{\cdot}atm>79.3{\mu}PET/PVDC/L-LDPE\;film\;13.4:6.4:34.2cc/m^2{\cdot}24hr{\cdot}atm>96.9{\mu}PE/PVDC/PE\;film\;15.3:7.1:42.0cc/m^2{\cdot}24hr{\cdot}atm>61.6{\mu}PVDC/PE/AL-vac/CPS\;film\;25.3:12.5:59.3cc/m^2{\cdot}24hr{\cdot}atm$ each other. And for preservation this were sealed to filths $N_2,\;CO_2$ gas or defilling ai (vacuum type) in the packaging and reserved less than $10^{\circ}C$ at refrigerator.

  • PDF

Effect of Sanitation Treatment of Extending Shelf-life on Fresh Poultry Meats (계육(鷄肉)의 유통기간연장(流通期間延長)을 위(爲)한 위생처리방법(衛生處理方法)에 관(關)한 연구(硏究))

  • Cho, M.J.;Jang, P.H.;Park, K.B.;Lee, B.M.
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.291-300
    • /
    • 1982
  • In order to develop effective and simple sanitation method for the extention of shelf-life of fresh poultry meat, the effect of sanitizers, sanitation methods and packaging materials on the extention of shelf-life of poultry meats was observed at the $4^{\circ}C$ and room temp$(10{\sim}20^{\circ}C)$. The results are summarized as follows: 1. The autochonous skin microflora of poultry, before processing, were believed to be removed or killed during the scalding and plucking, and exposed dermal tissue was contaminated by microorganisms from the subsequent stages of processing. 2. In the final stage of poultry processing, total viable counts of microorganisms and coliforms were averaged to $3.5{\times}10^4/cm^2$ and $400/cm^2$, respectively. 3. The refrigerated shelf-life of fresh whole poultry carcasses at $3\;to\;4^{\circ}C$ was extended to 7 to 16 days compared to control with the various treatments of some sanitizers by dipping freshly chilled carcasses for 5 min or spraying 1 liter of sanitizers per carcasses. In the case of storage at $10\;to\;15^{\circ}C$, the shelf-life of poultry carcasses was extended to one to two days by the sanitation treatments compared to control. 4. Spraying sanitation was more effective than dipping sanitation, and 5 minutes dipping and one liter spraying per carcass were enough for effective sanitation of poultry carcasses in most sanitizers. 5. The packaging with an oxygen impermeable polyvinylidene chloride extended the shelf-life to 10 days and 5 days with polyethylene compared to control. When poultry carcasses were sanitized by continuous spraying with one liter of 30 ppm of chlorine and another one liter of 5% of potassium sorbate, packaged with polyvinylidene chlorlde were extended to about 30 days compared to control.

  • PDF

A Dynamic Behavior Evaluation of the Curved Rail according to Lateral Spring Stiffness of Track System (궤도시스템의 횡탄성에 따른 곡선부 레일의 동적거동평가)

  • Kim, Bag-Jin;Choi, Jung-Youl;Chun, Dae-Sung;Eom, Mac;Kang, Yun-Suk;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.517-528
    • /
    • 2007
  • Domestic or international existing researches regarding rail damage factors are focused on laying, vehicle conditions, driving speed and driving habits and overlook characteristics of track structure (elasticity, maintenance etc). Also in ballast track, as there is no special lateral spring stiffness of track also called as ballast lateral resistance in concrete track, generally, existing study shows concrete track has 2 time shorter life cycle for rail replacement than ballast track due to abrasion. As a result of domestic concrete track design and operation performance review, concrete track elasticity is lower than track elasticity of ballast track resulting higher damage on rail and tracks. Generally, concrete track has advantage in track elasticity adjustment than ballast track and in case of Europe, in concrete track design, it is recommended to have same or higher performance range of vertical elastic stiffness of ballast track but domestically or internationally review on lateral spring stiffness of track is very minimal. Therefore, through analysis of service line track on site measurement and analysis on performance of maintenance, in this research, dynamic characteristic behaviors of commonly used ballast and concrete track are studied to infer elasticity of service line track and experimentally prove effects of track lateral spring stiffness that influence curved rail damage as well as correlation between track elasticity by track system and rail damage to propose importance of appropriate elastic stiffness level for concrete and ballast track.

  • PDF