• Title/Summary/Keyword: 산소발생기

Search Result 430, Processing Time 0.035 seconds

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

A Study on the Exhaust Gas Created by Staged Combustion and Gas Generator Cycle LRE by Using CEA (CEA를 이용한 다단연소사이클 및 가스발생기 사이클 LRE 배출가스 성분 분석)

  • Moon, In-Sang;Moon, Il-Yoon;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.863-866
    • /
    • 2011
  • Recently environmental issue is more and more emphasized and 'Green Growth' became on of the key words of this Government. Based on this trend, the exhaust gases out of the gas generator cycle and the staged combustion cycle LRE whose propellants are kerosene and LOx were compared. For this purse, 8 tonf class of each cycle engine was designed and the amount and the components of the gases were investigated by using CEA. As expected, the staged combustion cycle engine generates less pollutants than the other cycle. In addition, the graphite that is generated by the gas generator can be reacted with the oxygen in the atmosphere creating additional pollutants.

  • PDF

A Study on the Possibility of Application as a Natural Extinguishing System for $N_2$ Generator (산업용 질소발생기에 대한 청정소화설비로의 적용가능성에 관한 연구)

  • Suh, Byung-Taek;Jang, Young-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.139-144
    • /
    • 2010
  • An experimental study has been carried out to investigate the possibilities of an industrial $N_2$ generator that it replace Halon series as a natural extinguishing system. And this study comparison design standard of gas series extinguishing system with natural extinguishing system. We manufactured simple protected enclosure for analyzing fire-extinguishing performance of the $N_2$ generator. As a $N_2$ gas is exhausted on protected enclosure, a various of Oxygen concentration is measured to analyze fireextinguishing performance experimentally. The results, in case of $100m^3$ protected enclosure and $5m^3$/min $N_2$ flow rate, the Oxygen concentration is decreased below 15% within 3 minutes. And so, the $N_2$ generator make full use of an suffocating extinguishing system.

Characterization of oxygen plasma by using a langmuir probe in the inductively coupled plasma (정전 탐침을 이용한 유도 결합형 반응기에서 발생하는 산소 플라즈마의 특성연구)

  • 김종식;김곤호;정태훈;염근영;권광호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.428-435
    • /
    • 2000
  • Negative ion generation in an inductively coupled oxygen plasma was investigated by using a Langmuir probe. It was observed that the probe current ratio of the positive ion saturation current and the negative current which is consisted of the electron current and the negative ion current, and also the potential difference between the floating potential and plasma potential vary with the RF input power and more sensitively with the operating pressure, respectively. Results show that the operating condition to achieve the maximum probe current ratio and the minimum potential difference shift from the low pressure region to the high pressure regions with increasing the input power. It implies that the generation of the negative oxygen ions increases and the recombination of the positive and negative ions are enhanced in the plasma.

  • PDF

Cellular and Biochemical Mechanism of Perinatal Hypoxic-Ischemic Brain Injury (주산기 저산소-허혈 뇌손상의 세포 생화학적 기전)

  • Chang, Young Pyo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.5
    • /
    • pp.560-567
    • /
    • 2002
  • 주산기 뇌손상은 주로 급격한 저산소-허혈 손상에 의하는데 급격한 산소 공급의 차단은 oxidative phosphorylation을 정지 시켜서 뇌대사를 위한 에너지 공급이 차단되게 된다. 에너지 공급이 차단된 뇌세포는 뇌세포막에서 세포 내외의 이온 농도 차를 유지시키던 ATP-dependent $Na^{+}-K^{+}$ pump의 기능이 정지 되고, 세포 내외의 농도 차에 따라 $Na^{+}$, $Cl^{+}$, $Ca^{{+}{+}}$의 대규모 세포 내로 이동이 일어난다. 세포 내로 calcium 이온의 이동은 glutamate 수용체의 활성화에 의해서도 일나는데, 세포 내 calcium 이온의 증가는 protease, lipase, nuclease 등을 활성화 시켜 세포를 사망에 이르게 하는 연속적이고 다양한 생화학적 반응을 일으키게 된다. Glutamate는 대표적인 신경 전달 물질인데 저산소-허혈 손상 시 glutamate 수용체의 지나친 흥분은 미성숙 뇌에 뇌손상을 유발하는데, NMDA 또는 non-NMDA 수용체와 복합체를 형성하고 있는 calcium 이동 통로를 활성화 시켜 세포 내 calcium 이온을 증가시키고, 그 외에 metabotropic recetor는 G-protein의 활성화 등을 통해 뇌손상을 유발하는 다양한 생화학적 반응을 매개한다. 저산소-허혈 손상 후 재산소화와 재관류가 일어나면서 뇌세포의 지연성 사망(secondary neuronal death)이 일어나는데 이는 초기 손상 후 뒤이어 일어나는 다양한 생화학적 반응에 의하는데 다량의 산소 자유기 발생, nitric oxide의 생성, 염증 반응과 싸이토카인, 신경전도 물질의 과흥분 등이 관여하며, 신경 세포 사망은 세포괴사(necrosis)뿐 아니라 일부는 세포 사멸(apoptosis)로 알려진 의도된 세포 사망(programmed cell death)에 의한 것으로 생각되고 있다(Fig. 2).

Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(II) - Gas Generator (추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(II)-가스발생기)

  • Choi, Hwan-Seok;Seo, Seong-Hyeon;Kim, Young-Mog;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1038-1047
    • /
    • 2009
  • The development process of a gas generator for a 30-tonf pump-fed space liquid rocket engine is described. Starting from the development of an injector, followed by subscale and full-scale test specimens, the development of LOx/kerosene fuel-rich gas generator has been concluded successfully. Various analytical methods have been utilized in the course of design and the performance requirements have been verified experimentally through ignition tests, combustion performance and stability assessment tests and duration tests. The gas generator has proven its workability and stability within a defined operation window of varying chamber pressure and mixture ratio and demonstrated compliance to the performance and life time requirements.

Evaluation of Specific Impulse for Liquid Rocket Engine Adopting Gas Generator Cycle (가스발생기 사이클 액체로켓엔진의 비추력 평가)

  • Cho, Won-Kook;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.93-97
    • /
    • 2010
  • The analysis of specific impulse of the liquid rocket engine employing gas generator cycle with LOx/kerosene as propellant has been performed. The relative error of performance of 300 ton level engine is 0.1%s for specific impulse and 12% for optimal combustion pressure comparing with the published data. The difference of the performance model and the material property models of gas generator product gas are the presumed major reason of discrepancy. The optimal condition of 30 ton level engine is combustion pressure of 68 bar and mixture ratio of 2.2 for maximum specific impulse. This optimal condition can be changed by performance models.

Physicochemical Characteristics of Seawater in Gamak Bay for a Period of Hypoxic Water Mass Disappearance (가막만 빈산소 수괴 소멸기의 물리화학적 특성)

  • Kim, Jeong-Bae;Park, Jung-Im;Jung, Choon-Goo;Choi, Woo-Jeung;Lee, Won-Chan;Lee, Yong-Hwa
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.241-248
    • /
    • 2010
  • Hypoxic(oxygen-deficient) water masses are a key threat to the ecosystem of shallow marine coastal areas worldwide. The phenomena of hypoxia occurred at Gamak Bay, on the southeast coast of Korea, in late June 2007. In this paper, the physicochemical characteristics of seawater were surveyed for a period of hypoxic water mass disappearance. The hypoxic water mass was located between Sunso and the northwestern area of the inner bay. The dissolved oxygen(DO) concentrations of surface and bottom water were $1.3mgL^{-1}$ and less than $2mgL^{-1}$, respectively, in the hypoxic water masses, and $4.5{\sim}6.8mgL^{-1}$ and $3.8{\sim}6.0mgL^{-1}$ at the other oxygen-rich sample sites, respectively. Chlorophyll a concentrations were $4.9{\sim}25.3{\mu}gL^{-1}$ at the surface, $2.3{\sim}23.1{\mu}gL^{-1}$ in the middle, and $1.9{\sim}9.0{\mu}gL^{-1}$ at the bottom of the hypoxic water masses. When the hypoxic water mass appeared in Gamak Bay, it formed three different vertical types. The first type occurred throughout the water depth around Sunso. The second type developed from the bottom. The third type of hypoxic water mass was formed in the middle water layer when the inversion of water temperature occurred. The third type of phenomena appeared at only St. 9, St. 14 and St. 21 sites near the Hodo coast. Aquatic surface respiration of bottom-dwelling fishes such as the oriental goby(Acanthogobius flavimanus) was observed and many crustaceans were seen along the adjacent shore of the hypoxic water mass area. About 3,000 oriental gobies as well as many crustaceans died due to this event in Gamak Bay. The results of this study could provide fundamental data for the mechanism of hypoxic water masses in Gamak Bay.

Treatment of Ar/O2 Atmospheric Pressure Plasma for Sterilization (아르곤과 산소 대기압 플라즈마 방전 효과를 이용한 살균처리)

  • Son, Hyang Ho;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.261-265
    • /
    • 2011
  • The sterilization effects of atmospheric pressure plasma with the mixture of argon and oxygen were analyzed. The plasma reactor with the shape of dielectric barrier discharge produced the uniform distribution of glow discharge and generated ozone gas effectively according to the various process parameters. The sterilization for E. coli was affected by power, oxygen ratio in the mixture gas, treatment time and distance between reactor and sample. The concentration of ozone was a major source for the sterilization of E. coli, which was enhanced by the increase of power and oxygen ratio. In this study, the effect of atmospheric pressure plasma treatment for the sterilization was confirmed and its result can deliver the atmospheric pressure plasma treatment as the novel sterilization method instead of conventional methods.

Effect of Aeration Rate on Production of Somatic Embryo in Oenanthe stolonifera DC. (미나리 체세포배 생산에 미치는 환기율의 영향)

  • 김진아;윤혜진;이병일;손정익
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.174-175
    • /
    • 2001
  • 미나리 묘를 대량으로 생산하는데 있어서 체세포배를 이용하는 방법이 매우 유리하다. 체세포배는 계절에 영향을 받지 않고 좁은 공간에서 한꺼번에 많은 량의 묘를 생산할 수 있다. 또한 생물반응기 등을 이용하여 대량 생산할 수 있으면 실생묘를 대체할 수 있을 것으로 생각된다. 배양기 내의 공기 환경의 영향은 삼각플라스크를 이용한 소규모 배양에서는 문제가 되지 않았지만 배양기가 커짐에 따라 공기 환경의 변화도 커져 체세포배의 발생과 발아에 영향을 미친다. 체세포배를 배양하는 기간은 배발생과 발아로 나누어, 세포에서 배가 발생하는 처음 2주 동안에는 밀폐 환경, 즉 환기가 거의 되지 않는 환경이 유리하지만 이후의 발아 동안에는 산소를 많이 요구한다. 삼각플라스크를 이용한 소규모 배양에서는 aluminum foil을 플라스크의 뚜껑으로 하여, 배지를 교체할 때를 제외하고는 배발생과 발아가 진행되는 전 배양 기간 동안 이를 유지한다. 배가 발생하는 초기 2주의 경우는 이 밀폐 환경이 발아를 촉진시킨다. 그러나 배가 발아하여 정상 식물체로 발달하는데는 유리하지 않다. 체세포배는 발아할 때 산소를 많이 필요로 하며 에틸렌이 많이 축적되면 발아율이 낮아지며, 적절한 공기 환경이 주어지면 체세포배 발아가 동조화되어 균일한 묘를 얻을 수 있고 수확시기도 예측할 수 있다. 본 실험에서는 배가 발아하는 기간 동안 플라스크 내의 공기 환경을 다르게 하기 위해 플라스크를 막는 뚜껑의 소재를 달리하여 배양한 후 발아율을 측정하였다. 또한 가장 효율적인 환기량을 구명하기 위하여 인위적으로 플라스크에 공기를 넣어 강제 환기시키는 실험을 수행하였다. 미나리 cell은 처음 8일까지는 생장을 하지 않다가 이후 급속히 생장을 시작하여 35일 정도까지는 생장을 하다가 다시 생장이 둔화되었다. 밀폐시킨 삼각플라스크에서 자라는 Cell은 상태도 좋지 않고 전반적인 증식량도 적었다. Cell은 환기정도에 민감한 것으로 판단되며 삼각플라스크에서 약 35일 정도의 생장 주기를 가지는 것으로 사료된다. 배양 3주까지는 플라스틱 뚜껑으로 밀폐시킨 bottle에서 가장 많은 체세포배를 얻었다. Air filter를 달아 2일 마다 신선한 공기를 넣어 주었을 때는 배의 발달이 많이 늦어져 배양 3주째에 다른 처리보다 배의 수가 훨씬 적었다. 체세포배가 발달하는 동안에는 산소를 많이 요구하지 않으나 성숙하는 동안에는 산소를 많이 요구하는 것으로 생각된다.

  • PDF