• Title/Summary/Keyword: 산소량

Search Result 1,748, Processing Time 0.029 seconds

Coadsorptions of Carbon Monoxide and Oxygen on Polycrystalline Nickel Surface (다결정 니켈 표면에서의 CO 와 $O_2$의 공동흡착)

  • Soon Bo Lee;Jin Hyo Boo;Woo Sub Kim;Woon Sun Ahn
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.12
    • /
    • pp.1019-1024
    • /
    • 1993
  • The coadsorption of carbon monoxide and oxygen on polycrystalline nickel surface has been studied using XPS at the room temperaure. The adsorption of CO on the nickel surface precovered partially with oxygen is found to take place by the following steps: The CO molecules react with the preadsorbed oxygen atoms to liberate $CO_2$ gas at the initial stage of low CO exposures, and they are coadsorbed gradually with the increasing CO exposures. The extent of coadsorption at the higher CO exposures is found to decrease with the increasing degree of oxygen preadsorption. This finding is explained in terms of the reduced adsorption site for CO as a consequence of oxygen preadsorption. The CO molecules preadsorbed on the nickel surface inhibited the adsorption of $O_2$ molecules. The increase of oxygen exposure led to the dissociation of preadsorbed CO, and the NiO layers were formed concurrently. The dissociation was rendered to arise from an oxygen-to-CO energy transfer.

  • PDF

Anode Characteristics of $SnO_x$ Films with Various Oxygen Contents (산소량에 따른 $SnO_x$ 박막의 음극 특성)

  • Moon Hee-Soo;Seong Sang-Hyun;Kim Young-Il;Park Jong-Wan
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.3
    • /
    • pp.178-181
    • /
    • 2000
  • In this experiments, tin oxide thin film anode for microbattery was deposited by using RF magnetron sputtering. The RF power and operating pressure during deposition were fixed at $2.5W/cm^2$ and 10mTorr respectively. The partial pressure of oxygen was varied from $0\%\;to\;100\%$ to control oxygen content and metal Sn chips were used further reducing of oxygen content. According to reduction in the oxygen content formation of the irreversible $Li_2O$ was reduced a thin film anode of $SnO_x$ of high capacity was fabricated. The optimum $SnO_x$, thin film was $SnO_{1.43}$ which exhibited a reversible capacity of $ 500{\mu}Ah/cm^2{\mu}m$ and exhibited good reversibility.

Development of airflow control technology for Korean-type bioreactor based on influent water quality (유입수질 기반 한국형 생물반응조 송풍량 제어 기술 개발)

  • Yeo, Wooseok;Woo, Jea Suk;Song, Dong Hoon;Shin, Sung Bok;Kim, Jong Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.388-388
    • /
    • 2022
  • 하수처리 공정 중 생물반응조에서는 미생물의 산화 반응을 통해 하수 내 각종 유기물들을 처리하고 있다. 블로워는 호기조를 유리산소상태로 만들어 미생물들의 유기물 제어, 질산화가 원활하게 이루어질 수 있도록 지원하는 역할을 담당하고 있다. 그러나 실제 하수처리장에서는 유기물을 원활하게 처리하기 위하여 과도하게 블로워를 가동하고 있어 경제적인 측면에서 문제를 겪고 있다. 블로워를 통해 수중에 산소를 부족하게 공급할 경우 활성슬러지의 침전성이 저해되어 방류수 수질이 저해되는 반면, 용존산소가 과도하게 공급되어도 유기물질의 처리 효율은 증대되지 않으며 잉여용존산소는 대기 중으로 방류된다. 이러한 이유로 국내 하수처리장에서는 강화된 방류수 수질 기준을 만족하기 하고자 유입수질에 관계없이 과도하게 송풍기를 운영하고 있다. 이러한 하수처리장의 운영 및 경제적인 문제점을 해결하고자, 본 연구에서는 하수처리장으로 유입되는 원수의 수질을 처리하는 데 실제로 미생물이 필요한 산소요구량 및 공기공급량을 산정하는 프로그램을 개발하였다. 이를 통해 실제 하수처리장에서 필요한 산소요구량, 공기공급량을 산출하여 효율적인 하수처리장 운영이 가능하다. 실제 하수처리장에서의 프로그램을 통한 송풍량 절감 효율을 분석하고자 한 달간의 A 하수처리장 수질 데이터를 기반으로 하수처리에 필요한 산소요구량 및 공기공급량을 산정하였다. 실험 결과 프로그램 적용시 약 평균적으로 10%의 송풍량을 절감이 가능하며, 연구 결과를 바탕으로 효율적이고 경제적인 송풍기 운영조건의 기준을 제시하고자 한다.

  • PDF

Oxygen Effect of SiOxNy Films by RF Sputter (RF sputter에 의한 SiNy막 제작에서의 산소 주입효과)

  • 임성환
    • Electrical & Electronic Materials
    • /
    • v.2 no.1
    • /
    • pp.25-32
    • /
    • 1989
  • Silicon Nitride, Silicon OxyNitride, Silicon Oxide film을 RF Sputter법으로 제작하였다. RF power 1kw에서 산소 공급량과 기관온도에 따라 제작된 막의 조성을 ESCA로 분석하였으며 산소 공급량과 기판온도의 증가에 따라 막에서의 산소함량이 크게 증가하였다. 또한 막의 밀도, 굴절율, 유전율은 산소함량의 증가에 따라 감소하였고 분극율은 Clausius-Mossotti방정식에서 얻을 수 있었다.

  • PDF

포기 시간 변경에 따른 SBR의 영양염류 제거 특성과 MLVSS에 관한 연구

  • Jeong, No-Seong;Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.383-389
    • /
    • 2007
  • 호기시간 변경에 따른 SBR에서의 영양염류제거특성과 MLVSS의 변화를 본 이번 연구에서는 다음과 같은 결론을 얻었다. 1) 충분하지 못한 산소의 공급은 미생물의 wash-out으로 인한 영양염류 제거 효율의 저조를 나타냈다. 2) 산소 공급량이 $0.045m^3$였던 R2에서 저조산 질산화가 나타났으나, 인을 과다 축적하는 EBPR(Enhanced Biological Phosphorus Removal)을 나타냈다. 3) 산소 공급량이 $0.06m^3$이상이었던 R3, R4에서는 60%이상의 질산화 및 탈질화와 약 100%에 달하는 인 제거 효율을 나타내었다. 4) 단위 미생물당 $1.5{\sim}1.8ml/mg$의 공급 산소량이 인 흡수에 유리한 것으로 나타났다. 5) 공급되는 산소에 있어 유기물 분해>인흡수>질산화에 우선적으로 소모되는 것으로 나타났다.

  • PDF

Characteristics of Total Organic Carbon and Chemical Oxygen Demand in the Coastal Waters of Korea (한국 연안수에서 총유기탄소 및 화학적 산소요구량 분포 특성)

  • 손주원;박용철;이효진
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.3
    • /
    • pp.317-326
    • /
    • 2003
  • In order to improve our knowledge of the characteristics of organic compounds in coastal waters, water samples were collected from the Incheon coastal region, the Hyungsan River in Youngil Bay and the Busan coastal region. Also, mooring was carried out near the Kanghwa Island and Seo Island. In this study, the relationship between the total organic carbon (TOC) and salinity, chemical oxygen demand (COD) and salinity were evaluated and determined. Riverine end-member of TOC into the Korean coastal area and its COD estimated from these relationships were 5.32 mg C/l and 8.87 mg O$_2$/l, respectively. The oxidation efficiency of COD to TOC estimated using the high-temperature catalytic oxidation method was about 47%. The linear relationship between TOC and COD was derived as COD (mg O$_2$/l)=0.61${\times}$TOC (mg C/l) -0.03, (R$^2$=0.66). Therefore, it is possible to estimate total organic carbon using this equation from previously reported chemical oxygen demand.

Separation characteristics of separation devices using inlet water mixed with exhalation gases without a compressor (날숨이 혼합된 물을 사용한 압축기없는 용존기체 분리기의 분리 특성)

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.842-846
    • /
    • 2016
  • It's possible for a human to breathe under water, but the amount of dissolved oxygen in the water is small and a large amount of water is necessary to obtain sufficient dissolved oxygen from water. So, large separation system with large water pumps, having large surface areas, and large battery sources are needed. Exhalation gases are used to solve this problem. Theses gases contain some oxygen, nitrogen, and carbon dioxide; they contain less oxygen and more carbon dioxide compared to air. Therefore, reduction of the amount of carbon dioxide is necessary. If exhalation gases are employed appropriately, the separation device can be made more compact. Inlet water mixed with exhalation gases is supplied into the separation device, and dissolved gases are separated from the mixed water as it passes through the device. The inlet part of a typical separation system with a water delivery pump before the membrane module has more than one atmosphere. Hence, a compressor is used to mix the exhalation gases. In this study, the pressure at the inlet due to the use of a suction pump after the membrane module was less than one atmosphere; hence, compressors were not required. Separation characteristics were studied using a separation device without a compressor. The use of exhalation gases led to an increase in the amount of dissolved gases being separated. As the amount of inlet exhalation gases was increased, the separation of dissolved gases was increased as well.

가막만 소호해역에서 태풍 전후 수질 변동특성

  • Lee, Yeong-Sik
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.294-297
    • /
    • 2007
  • 유기유기물 증가원인의 파악과 근본적인 대책에 대한 연구의 일환으로 부영양화된 연안해역에 대하여 태풍 발생 전후의 수질변동에 대하여 조사하였다. 그 결과를 요약하면 다음과 같다. 1) 용존산소 포화도는 수온과 염분 약층이 형성된 시기에 저층에서 54% 이하로 관측되었다. 태풍이 지나간 직후에는 표층과 저층에서 거의 비슷한 용존산소 포화도$(78{\sim}88%)$가 조사되었다. 그리고, 태풍이 지나간 3일 후 식물플랑크톤이 대량으로 증식한 표층에서 용존산소 포화도가 234%로 아주 높은 값이 관측되었고, 저층(5m)에서도 90%가 조사되어, 태풍과 식물플랑크톤의 이상 증식이 저층의 용존산소 포화도를 높이는 작용을 한 것으로 보인다. 2) 염분이 가장 낮았던 시기에 표층에서 $NA_4-N$, $NO_3-N$, $SiO_2-Si$의 농도가 각각 18.22, 38.90, 52.10uM로 아주 높게 조사되었으며, $NH4-N$, $PO_4-P$, $SiO_2-Si$는 용존산소가 낮은 저층에서도 높게 나타났다. 3) 클로로필은 최고 $311.0{\mu}g/L$가 태풍 후에 관측되었으며, 그 원인 생물은 Scrippsiella trochoidea (42,000cells/mL)였다. 조류성장잠재능력은 태풍발생 후에 아주 높게 조사되었으며, 항상 질소가 부족한 것으로 조사되었다. 4) 화학적 산소요구량은 최고 10.55 mg/L였으며, 태풍으로 저층 퇴적물로부터 부유되는 유기 오탁 물질이 화학적 산소요구량 증가에 미치는 기여도는 크지 않은 것으로 보이며, 화학적 산소요구량 증가의 대부분이 식물플랑크톤의 증식에 기인한 것($r^2=0.612$, p<0.0001)으로 조사되었다.

  • PDF

Effect of Salinity on Dissolved Oxygen Characteristics in an Ejector-Aerator (이젝터-폭기 시스템의 용존산소특성에 미치는 염도의 영향)

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.640-646
    • /
    • 2011
  • Dissolved oxygen (DO) refers to the volume of oxygen that is contained in water, and is a major indicator of water quality. The objective of this paper was to investigate the effect of salinity on the dissolved oxygen characteristics in an ejector-aerator. An experimental aeration system composed of a motor-pump, an ejector, a motor-blower, a set of aeration and recirculation tank and a control panel. The dissolved oxygen concentrations decreased with the water salinity. The volumetric mass transfer coefficient increased with increasing the water salinity.

RETF 액체산소 공급설비 및 엔진 수류시험

  • Han, Yeoung-Min;Cho, Nam-Kyung;Kim, Seung-Han;Chung, Yong-Ghap;Park, Sung-Jin;Lee, Kwang-Jin;Kim, Young-Han;Moon, Il-Yoon
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • In this paper, characteristics of cryogenic liquid oxygen was examined during cold flow of KSR-III main engine at each stage. The effect of venting was examined at the stage of cooling and at the pressurization stage, the interaction between nitrogen gas and liquid oxygen was also examined. The characteristic of liquid oxygen in the engine manifold was analyzed. The results showed that venting was the primary role at the cooling process and the interaction of nitrogen gas and liquid oxygen in the run tank is limited at the surface area. With the sampling rate of 1KHz static and dynamic pressure were measured in the rocket engine manifold and in the LOX supply equipment. 32.5mm and 38mm orifice were installed for the tests and pressure condition of liquid oxygen was 23Bar, 29Bar, 41Bar. Increase of orifice diameter and decrease of supply pressure reduced the perturbation of pressure in engine manifold.

  • PDF