Clinical Test of prototype Oxygen Concentrator (국산 산소농축기 시제품의 임상시험)

  • Kim, Seung-Chul;Sung, Sook-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.44-52
    • /
    • 2001
  • Background : Oxygen concentrators are convenient to operate and economical for patients with chronic obstructive pulmonary disease (COPD). However, oxygen concentrators are not manufactured domestically and the COPD patients are currently treated with imported oxygen concentrators. To evaluate the efficacy and safety of domestically developed prototype oxygen concentrator before clinical application, the efficacy and safety of the domestic oxygen concentrator were evaluate by comparing with the imported one. Material and Methods : The clinical tests were performed on 36 hyperhydrosis patients from April 1999 to August 1999. Domestic and imported oxygen concentrators were in turn applied to the same patient, who inspired oxygen for 60 minutes at a rate of 3 liters per minute through nasal prong. The oxygen concentrator, which was applied first, was randomly allocated. The arterial partial oxygen pressure ($PaO_2$) was estimated to compare the efficacy; and the carboxy hemoglobin(COHb), pH, arterial $CO_2$ partial pressure, pulse rate, blood pressure, and respiration rate to compare the safety before and after applying each oxygen concentrator. A student t-test was used to analyze the results. Result : In respect to efficacy, the difference in the change of $PaO_2$ before and after the application between two concentrators was not statistically significant. In respect to safety, the differences in the changes of COHb, pH, partial pressure of arterial $CO_2$, pulse rate, blood pressure, respiration rate between two concentrators were also not statistically significant. Conclusion : The domestically developed oxygen concentrator, showed satisfactory efficacy and safety when compared with the imported one.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Adsorption Characitritics of Sorbent for Oxygen Generator (산소발생기용 흡착제의 흡착특성)

  • Choi Sang-Il;Jang Hyun Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.315-317
    • /
    • 2005
  • 공기중의 산소농축 PSA 기술로 RPSA(Rapid Pressure swing adsorption)이 적용되므로 1979년 이후 소형의 의료용 장치로 상업화되기 시작하였다. 산소발생기(산소농축기)의 경우에도 개량형 RPSA방식을 적용한 기술로써 최근 우리나라도 고령화 사회가 되므로써 의료용으로 사용이 확대되고 있으며, 기타 작업장이나 특수 시설 등에서 사용이 증대되고 있다. 이러한 산소농축기의 핵심부품 중의 하나인 흡착탑의 경우 흡착제 구성 및 흡착탑의 구조에 의하여 성능이 좌우되고 있다. 현재 상용화된 제올라이트의 각 흡착제의 흡착특성을 도출하기 위하여 압력, 온도, 수분함유량에 따른 파과곡선을 측정하여 흡착탑의 단수에 따른 최적 단수를 도출하였다.

  • PDF

Effects of Membrane Filtration Concentrate of Sewage Reuse Facility on Performance of Bioreactor in Sewage Treatment Facility (하수재이용시설 농축수가 하수처리장 생물반응조 운영에 미치는 영향)

  • Lim, Ji-Young;Kim, Hyun-Sik;Bae, Min-Su;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.5-14
    • /
    • 2018
  • This study investigated the effect of concentrate of membrane filtration of sewage reuse facilities on bioreactor's microorganisms in sewage treatment facility, and concentrate was analyzed, oxygen uptake rate and continuous activated sludge experiment were performed. As a results, the concentration of organic matter and TP concentration in concentrate was closely related to the concentration of SS and the concentration of ionic substances in concentrate was higher in order of $Cl^-$ > $Na^+$ > $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $F^-$. And the analysis value of analytical items was greatly fluctuated according to sampling time of concentrate. Result of OUR test according to the mixing ratio of concentrate to sewage, it was found that the concentrate acts as an organic matter in the activated sludge microorganism and it increases with the increase of the concentrate mixing ratio. As a result of continuous activated sludge experiment, MLSS concentration, organic removal efficiency and TN removal efficiency gradually decreased with increasing concentrate mixing ratio. Based on the experimental results, expected mixing ratio of concentrate to affect the treatment efficiency of activated sludge is 25%.

Separation of Oxygen from Air using Rapid Pressure Swing Adsorption (RPSA) Process (Rapid Pressure Swing Adsorption (RPSA) 공정을 이용한 공기에서의 산소 분리)

  • Choi, Jae-Wook;Lee, Hwa-Ung;Song, Hyung-Keun;Suh, Sung-Sup;Na, Byung-Ki
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • RPSA (Rapid Pressure Swing Adsorption) is a cyclic process which can be used to separate gas mixtures by adsorption method. Oxygen which is separated from air is used to the medical oxygen generator and biological wastewater treatment process. RPSA uses only one adsorption bed, so it is very simple to operate compared to conventional PSA process. In this work experimental parameters were examined with RPSA setup and parameters for the oxygen separation from air were obtained.

  • PDF

Performance of Parallel Current Air Driven Type Foam Separator in a Pilot-Scale Recirculating Aquaculture System (Pilot-scale 순환여과식 양식장에서 병류 공기구동식 포말분리장치의 성능)

  • Suh Kuen Hack;Kim Byong Jin;Kim Yong Ha;Lee Seok Hee;Suh Cha Soo;Cheon Jae Kee;Jo Jea Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.2
    • /
    • pp.140-145
    • /
    • 2002
  • The performances of a parallel current air driven type foam separator were evaluated in the pilot-scale recirculating aquaculture system. The system was stocked with Nile tilapia (Oreochromis niloticus) at an initial rearing densities of $2\%$, $5\%$ and $7\%$ of water volume of rearing tank and reared for 15, 30, 35 days, respectively. The condensated volume of effluent foam was increasing with increased rearing density. As increasing rearing density from $2\%$ to $7\%$, the protein concentration in rearing tank was increased from 16.6 g/$m^3$ to 21,9 g/$m^3$ and the removal amount of protein through foam separator as increased from 0.99 g/day to 2.5 g/day. But protein concentration ratio in the foam was decreased from 3.2 to 1.9. Changes of the removal amount and the concentration ratios of total suspended solid (TSS) and chemical oxygen demand (COD_cr.) were similar to proteins. The highest concentration ratios of TSS and COD_cr. were 10.2 and 8.4 at 2$2\%$ of rearing density.

고리 1호기 증기발생기 전열관의 2차측 응력부식균열 Part I: 손상원인 분석

  • 박인규;황일순;황세기;이상학;이계용;김봉수;홍연완
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.211-216
    • /
    • 1995
  • 1994년 11월에 나타난 고리 1호기 증기발생기의 전열관 누설에 대한 원인을 조사하기 위하여 인출 전열관의 파손 분석과 슬러지 분석 및 pH 분석 등을 수행하였다. 손상원인은 국부적인 염기도 상승과 부식전위 상승에 따른 2차측 응력부식균열(ODSCC)로 밝혀졌다. 전열관 표면과 접한 관판 상부의 퇴적슬러지 끝단에 형성된 틈새에서 나타나는 비등현상으로 $Na^{+}$ 등의 양이온이 농축하게 되며, Cl$^{-}$ 등의 음이온 증발로 인하여 국부적으로 염기도의 상승현상이 야기되었다. 또한 재 가동시 전열관 표면에 침착된 잔류 구리와 용존산소의 결합으로 부식전위가 상승되었다. 이와 같은 ODSCC 발생환경은 1990년이래 지속적으로 형성된 것으로 판단된다.

  • PDF

Clinical Experience of Long-term Home Oxygen Therapy (재택산소요법을 받고 있는 환자들에 대한 임상 관찰)

  • Lee, Young-Suk;Cha, Seung-Ick;Han, Chun-Duk;Kim, Chang-Ho;Kim, Yeun-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.283-291
    • /
    • 1993
  • Background: Long-term low flow oxygen therapy not only increases survival, but also improves the quality of life in patients with chronic obstructive pulmonary disease (COPD) with chronic hypoxemia. For the assessment and improvement of the status of home oxygen therapy, we analyzed clinical experience of 26 patients who have been administered low flow oxygen at home. Method: Twenty-six patients (18 men and 8 women) who have been received long-term oxygen therapy (LTOT) at home were examined. We reviewed physical characteristics, clinical history, pulmonary function test, ECG, arterial blood gas analysis, hemoglobin and hematocrit, types of oxygen devices, inhalation time per day, concentration of administered $O_2$, duration of $O_2$ therapy, and problems in the home oxygen therapy. Results: The underlying diseases of patients were COPD 14 cases, far advanced old pulmonary tuberculosis 9 cases, bronchiectasis 2 cases, and idiopathic pulmonary fibrosis 1 case. The reasons for LTOT at home were noted for cor pulmonale 21 cases, for dyspnea on exertion and severe ventilatory impairment 4 cases, and for oxygen desaturation during sleep 1 case. The mean values of aterial blood gas analysis before home oxygen therapy were $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg, and $SaO_2$ 87.7%. And the mean values of each parameters in the pulmonary function test were VC 2.05 L, $FEV_1$ 0.92 L, and $FEV_1$/FVC% 51.9%. Nineteen patients have used oxygen tanks as oxygen devices, 1 patient oxygen concentrator, 2 patients oxygen tank and liquid oxygen, and other 4 patients oxygen tank together with portable oxygen. The duration of oxygen therapy was below 1 year in 3 cases, 1~2 years in 15 cases, 3~5 years in 6 cases, 9 years in 1 case, and 10 years in 1 case. All patients have inhalated oxygen with flow rate less than 2.5 L/min. And only 10 patients have inhalated oxygen more than 15 hours per day, but most of them short time per day. Conclusion: For the effective oxygen administration, it is necessary that education for long-term low flow oxygen therapy to patients, their family and neighbor should be done, and also the institutional backup for getting convenient oxygen devices is required.

  • PDF

Development of Oxy-fuel Combustor for the Underwater SMV(Sub-Merged Vaporizer) (수중연소식 천연가스기화기(SMV)용 순산소 연소기 개발)

  • Sohn, Whaseung;Kim, Hoyeon;Jeong, Youngsik
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.253-254
    • /
    • 2014
  • 지구온난화 문제는 한국가의 문제가 아니라 인류의 문제로 대두되어 많은 이에대한 많은 연구가 이루어 지고 있다. 지구온난화의 주 대상물질인 화석연료로부터 연소시 발생하는 이산화탄소를 감축하기위한 많은 규제와 노력이 요구된다. CCS(Carbon Capture & Storage)란 화석연료로 부터 연소시 대기 중으로 배출되는 온실가스($CO_2$)를 포집하여 재생 또는 지중, 해양에 저장하는 기술로서 국가녹색성장 핵심기술중의 하나로 분류되며, $CO_2$ 회수방안, 저장, 처리관련 연구를 비롯하여 국내외 적으로 활발한 연구가 이루어 지고 있다. 또한 순산소 연소기술을 통한 $CO_2$ 회수, 처리기술은 연료의 산화제를 공기대신 순도 95% 이상의 고농도 산소를 이용하여 순산소연소를 하며, 이때 발생하는 배가스의 대부분은 $CO_2$와 수증기로 구성되어 있다. 발생된 배가스의 약 70~80%를 다시 연소실로 재순환시켜 연소기의 열적 특성에 적절한 연소가 가능하도록 최적화함과 동시에 배가스의 $CO_2$ 농도를 80% 이상으로 농축시켜 회수를 용이하게 하며, 동시에 공해물질은 NOx 발생량을 10ppM 이하로 줄일 수 있는 기술이다. 천연가스를 생산하는 LNG기지에서 연소에 의한 이산화탄소를 발생시키는 기기로는 수중연소식기화기(SMV ; Submerged Combustion Vaporizer)를 들 수 있다. SMV는 버너를 이용하여 $-162^{\circ}C$ LNG를 $10^{\circ}C$의 LN로 기화시키는 설비로서 특히 동절기에 작동시키며 $CO_2$를 배출시키는 연소기다. 본 연구에서는 수중연소식 SMV에 순산소 연소방식을 적용하여 천연가스와 산소를 연소시키므로서 발생되는 $CO_2$를 LNG냉열을 이용 액체화 시켜 회수하는 연구를 수행하고 있다. 내용중에 수중연 소식 SMV에 대한 순산소 연소기를 개발하는 연구를 수행하였으며, 실제 SMV의 1/10크기, 열량기준 1/900로 모형을 제작하여 실험하였다. 연소기 노즐 은 직경 0.6mm, 배가스가 수조내에서 48개의 노즐을 제작하였다. 실험결과 일정량 이상의 $CO_2$ EGR율이 일정 값 이상이 되면 화염의 길이가 공기/NG 화염 길이와 큰 차이가 없었으며 $CO_2$ EGR율이 100%이상에서는 $CO_2$ EGR율 증가에 따른 화염길이 변화는 크게 나타나지 않았다. CO 배출 농도는 공기/NG 연소의 경우보다 높게 나타났으며, ${\lambda}$가 1.4보다 높은 조건에서는 측정되지 않았다. NOx의 배출 농도는 약 1~8ppm으로 나타났다.

  • PDF

Study on the Stability of Anthocyanin Pigment in 'Comet' radish (I) (적환 20일 무우 색소의 안정성에 관한 연구(I))

  • Park, Chul-Jin;Na, Mi-Kyung;Oh, Sung-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.407-410
    • /
    • 1993
  • Stability of the anthocyanin pigment isolated from 'Comet' radish was decreased with increase of pH from 1.0 to 8.0. The destruction rate of anthocyanin at early stage was faster at pH 1.0 than pH 2.0 and 3.0, increased with increase of storage temperature from $0^{\circ}C\;to\;40^{\circ}C$. Thus the pigment preservability at $0^{\circ}C\;and\;40^{\circ}C$ after 10 days was 92.5% and 48.1%, and the half life at $0^{\circ}C\;and\;40^{\circ}C$ was 94.9 and 12.1 days, respectively Pigment was decreased with increase of ascorbic acid content from 0.015g to 0.05g.

  • PDF