• Title/Summary/Keyword: 삭제방법

Search Result 636, Processing Time 0.029 seconds

A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth (치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구)

  • Kim, Kyong-Nim;Yoon, Young-Ju;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.567-578
    • /
    • 2001
  • To investigate the difference of Texture exhibited on interproximal enamel surface with each different stripping method and the susceptibility of proximal enamel to demineralization after stripping and the application of a topical fluoride go] and sealant, one hundred human premolars, which were Previously extracted for orthodontic reasons were evaluated by means of Scanning electron microscopy and laser fluorescence. The results were as follows : 1. No matter what the initial stripping instrument was the furrows that resulted from all the stripping methods were not completely removed by careful polishing. 2. Among the enamel surfaces that were treated with three different initial abrasive instruments, followed by the same polishing method (Sof-$Lex^{(r)}$ disks), the enamel surfaces that were treated with 700 crosscut carbide bur showed the smoothest surfaces. 3. The stripped teeth, no matter what the initial stripping instrument was, were less resistant to initial demineralization than untreated teeth. But no difference in caries susceptibility according to differently stripped methods was found (p<(0.001). 4. Teeth treated with APF-gel or sealant were mote resistant to demineralization than those treated without other treatment after stripping (p<0.001). 5. Comparing groups treated with APF-gel to groups treated with sealant, the former was more resistant to demineralization than the tatter (p<0.05). In conclusion, enamel surfaces that were stripped jnterproximally were less resistant to demineralization even though various attempts were made to produce smooth, self-cleaning enamel surfaces. Therefore, additional treatment-sealant or calcifying/ fluoridating solution To the stripped enamel surfaces is recommended.

  • PDF

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF

Web Site Construction Using Internet Information Extraction (인터넷 정보 추출을 이용한 웹문서 구조화)

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

THE FISSURE PENETRATION AND MICROLEAKAGE OF PIT AND FISSURE SEALANT WITH MECHANICAL PREPARATION (기계적 삭제방법을 이용한 치면열구전색제의 열구 침투도 및 미세누출)

  • Kim, Ji-Yeon;Lee, Jae-Ho;Park, Ki-Tae;Kim, Seong-Oh;Choi, Byung-Jai;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.164-173
    • /
    • 2005
  • Mechanical preparation has been introduced to provide the sealant retention. The objective of this study was to compare the fissure penetration and the microleakage of pit and fissure sealant using mechanical preparation(mechanical preparation + acid etching) and acid etching only. An additional objective of this study was to compare the fissure penetration and the microleakage of unfilled and filled sealant in both methods. Sixty human premolars extracted for orthodontic purpose were selected. Thirty teeth were acid etched alone and remaining thirty teeth were prepared with a $\frac{1}{4}$ round bur and then acid etched. One-half of teeth in each surface treatment method were sealed with unfilled sealant and the other half were sealed with filled sealant. All of the teeth were thermocycled for 1200 cycles at $5^{\circ}C\;and\;55^{\circ}C$ and immersed in 5% methylene blue for 24 hours. Each tooth was sectioned bucco-lingually at mesial pit and distal pit and examined under a Measurescope. In the case of mechanical preparation, fissure penetration of sealant was significantly increased compared with the case of acid etching only(P < 0.05). The filled and unfilled sealant using mechanical preparation showed significantly decreased microleakage when compared with the unfilled sealant using acid etching only(P < 0.05). No differences were found in fissure penetration and microleakage between unfilled and filled sealant in both methods. Taken together, the results of this study suggest that mechanical preparation and filled sealant are recommended when placing pit and fissure sealant. However, further clinical studies should be performed in regard to microleakage.

  • PDF

A Study on Pattern Extraction and Complete Elimination Method of Private Information (개인정보의 패턴 추출과 완전삭제방법에 관한 연구)

  • Seo, Mi-Suk;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.143-146
    • /
    • 2012
  • Enforcement of private information preservation law the infringement accident which is still caused by despite with private information outflow occurs. The private information outflow avoids finance and to become the fire tube. Analyzes the pattern of private information from search of private information and detection process and the research which it extracts and the research is necessary in about perfection elimination of the private information which is unnecessary. From the research which it sees it researched a pattern extraction research and a complete elimination method in about private information protection and it did the pattern extraction and a complete elimination experiment of private information.

  • PDF

The Pattern Search and Complete Elimination Method of Important Private Data in PC (PC에서 중요개인정보의 패턴 검색과 완전삭제방법 연구)

  • Seo, Mi-Suk;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.213-216
    • /
    • 2013
  • Big data, the use of privacy has been increasing to the development of wireless network infrastructure or technology development and wired Internet. By the way, Enforcement of private data preservation law the infringement accident which is still caused by despite with private data outflow occurs. The private data outflow avoids finance and to become the fire tube. Analyzes the pattern of private data from search of private data and detection process and the research which it extracts and the research is necessary in about perfection elimination of the private data which is unnecessary. From the research which it sees it researched a pattern extraction research and a complete elimination method in about private data protection and it did the pattern extraction and a complete elimination experiment of private data.

  • PDF

Porcelain Laminate Veneer Restoration (Porcelain laminate veneer의 수복)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.191-200
    • /
    • 2012
  • The patients' demand for treatment of unesthetic anterior teeth is steadily growing. Accordingly, several treatment options such as porcelain laminate veneers(PLV) have been proposed to restore the esthetic appearance of the dentition. Porcelain laminate veneers are considered minimally invasive, but they also require removal of sound enamel. One critical step in the porcelain laminate veneer technique is the achievement of sufficient ceramic thickness, and several different strategies for tooth preparation can be found in the literature. This clinical report describes a step-by-step protocols for preparation of these restorations used with the silicone index from diagnostic wax-up and the acrylic resin mock-up. Conservative use of porcelain laminate veneers provided satisfactory esthetic outcomes and preserved sound tooth structure.

Truncation and Recovery of Transform Coefficients for Coding Arbitrarily-Shaped Image Segments (임의 형태 영상 영역 부호화를 변환 계수의 삭제 및 복원)

  • 김지홍
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 1998.10a
    • /
    • pp.237-242
    • /
    • 1998
  • 본 논문에서는 임의 형태 영상 영역에 대한 새로운 변환 부호화 방법을 제안한다. 제안된 방법에서는 영상 영역을 구성하는 각 열의 화소들을 변환 블록의 상단으로 이동시킨 후, 비어 있는 부분을 각 열의 화소 평균값으로 외삽한다. 그리고 수직 방향 1차원 변환을 실행한 후 외삽된 부분의 변환 계수들을 삭제한다. 수평 방향 1차원 변환은 각 행의 변환 계수들을 변환 블록의 좌측단으로 이동시킨 후, 수직 방향 1차원 변환에서와 동일한 과정을 실행함으로써 이루어진다. 복호화를 위해서는 먼저 삭제된 변환계수들을 복원한 후에 수평 방향 1차원 역변환 과정을 수행하며, 역변환 계수들 중 복원된 부분의 계수들을 삭제한다. 그리고 수평방향의 1차원 역변환 과정은 수직 방향 1차원 역변환 과정과 동일한 방식으로 수행한다. 역변환으로 만들어진 재생 영상은 변환 계수와 함께 전송된 형태 정보를 이용하여 원 위치로 이동된다. 모의 실험 결과는 제안된 방법의 압축 성능이 낮은 비트율에서 특히 우수함을 보여준다.

  • PDF

A Method Processing Missing Values for Data Mining based on Artificial Neural Network (데이터 마이닝을 위한 신경망 이용 결측 값 처리 방법)

  • 성지애;류정우;김명원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.446-448
    • /
    • 2003
  • 실세계의 많은 데이터는 결측 값들을 포항하고 있기 때문에 데이터 마이닝 시스템에 완벽한 데이터를 제공하기는 불가능하다. 또한 결측 값이 존재하는 대용량의 데이터를 추천시스템에 적용하여 분석하고자 할 경우, 정확성이 떨어지는 결과를 초래할 수 있다. 따라서 데이터에 결측 값이 존재할 경우 입력 데이터를 사전에 보간하는 전처리 방법이 필요하다. 이러한 기존의 보간 전처리 방법에는 결측 값 속성을 삭제하거나 대치하는 방범이 대표적이나. 삭제 방법은 결측 값이 존재하는 데이터를 제거하는 방법으로 중요속성 삭제 및 데이터 손실을 유발하는 단점이 있어 일반적으로 결측 값을 다른 값으로 처리하는 대치 방범이 널리 사용된다. 본 논문에서는 전처리 방법 중 결측 값을 처리하는 가장 일반적인 대치 방법과 신경망을 이용한 평가 예측 처리 방법을 소개한다. 또한 신경망을 이용 결측 값을 대치하는 새로운 모델을 제안하고, 각각의 결측 값 처리방법을 비교 분석한다.

  • PDF