• Title/Summary/Keyword: 사체

Search Result 728, Processing Time 0.031 seconds

MICRONEUROSURGICAL RECONSTRUCTION OF THE ORAL AND MAXILLOFACIAL REGION USING THE SURAL NERVE;HISTOLOGIC STUDY (비복신경을 이용한 구강 및 악안면 영역의 신경재건;해부학적 특성에 관한 연구)

  • Kim, Myung-Jin;Kim, Byeong-Rin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 1991
  • Various nerves from many areas of body can be used as a donor of autogenous nerve graft in the microneurosurgical repair of the oral and maxillofacial region. In the grafting procedure of nerve repair, the best results will be achieved with a maximum approximation of fascicular surface at both the porximal and the distal stumps. Therefore, appropriate selection of donor nerve will bring out the best results. The sural nerve has been used as one of the most popular donor nerve in the microneurosurgical repair of the oral and maxillofacial region. The authors examined the fascicular characteristics of the human sural nerve microscopically and compare this results with our previous report of the greater auricular nerve and that of the inferior alveolar nerve.

  • PDF

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.

Isolation and Purification of Protein-bound Polysaccharides from Mycelia of Flammulina velutipes Grown on Sawdust Medium (팽나무버섯 수확후의 톱밥배지로부터 단백다당류의 분리 및 정제)

  • Ha, Hyo-Cheol;Park, Shin;Park, Kyung-Sook;Lee, Shun-Woo;Jung, In-Chang;Kim, Seon-Hee;Kwon, Yong-Il;Lee, Jae-Sung
    • KSBB Journal
    • /
    • v.10 no.5
    • /
    • pp.589-597
    • /
    • 1995
  • Protein-bound polysaccahrides(PBP) were isolated, purified, and characterized from the sawdust media after harvesting the fruit body of Flammulina velutipes. The yield of the crude PBP(Fr.CA) extracted from the sawdust media, was 0.367% relative to the original sawdust media. The total sugar and protein contents of Fr.CA were 19.8% and 23.8% respectively. Using the membrane filtration, the fraction of which the molecular weight is over 300 kDa(Fr.A) was isolated from the Fr.CA and the yield was 44.6% relative to the Fr.CA. This result indicates that high molecular PBP is the dominant components of the Fr.CA. The Fr.A was separated into three fractions (Fr.A-1, Fr.A-2 and Fr.A-3) whose yields are 5.8%, 8.5% and 13.2% respectively. These fractions were further purified using gel filtration, obtaining a single peak in each fraction that considered as pure PBP Among them, the yield of Fr.A-1-${\alpha}$ was 20.9% relative to the Fr.A-1, and the molecular weight was 800 kDa. Monosaccharide components such as glucose, galactose, mannose, xylose and fucose could be detected all fractions by a HPLC analysis. Especially in the Fr.A-1-${\alpha}$ fraction, the content of glucose and galactose appeared to be high.

  • PDF

Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis (대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석)

  • Won Ye-Yeon;Baek Myong-Hyun;Cui WenQuan;Chun KeyoungJin;Kim Man Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.519-523
    • /
    • 2004
  • This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using Micro-CT and finite element-model. 15 cored trabecular bone specimens with 20min of diameter were obtained from femoral heads with osteoporosis (T-score > -2.5 ) resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indices. Based on obtained micro-images(pixel size=21.31㎛), a FE-model was created to determine mechanical property indices. While non-osteoporosis group had increases trabecular thickness, bone volume, bone volume fraction, degree of anisotropy and trabecular number compared with those of non-osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indices, reaction force, apparent stress and young's modulus were 1ower in osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.

Improved SIM Algorithm for Contents-based Image Retrieval (내용 기반 이미지 검색을 위한 개선된 SIM 방법)

  • Kim, Kwang-Baek
    • Journal of Intelligence and Information Systems
    • /
    • v.15 no.2
    • /
    • pp.49-59
    • /
    • 2009
  • Contents-based image retrieval methods are in general more objective and effective than text-based image retrieval algorithms since they use color and texture in search and avoid annotating all images for search. SIM(Self-organizing Image browsing Map) is one of contents-based image retrieval algorithms that uses only browsable mapping results obtained by SOM(Self Organizing Map). However, SOM may have an error in selecting the right BMU in learning phase if there are similar nodes with distorted color information due to the intensity of light or objects' movements in the image. Such images may be mapped into other grouping nodes thus the search rate could be decreased by this effect. In this paper, we propose an improved SIM that uses HSV color model in extracting image features with color quantization. In order to avoid unexpected learning error mentioned above, our SOM consists of two layers. In learning phase, SOM layer 1 has the color feature vectors as input. After learning SOM Layer 1, the connection weights of this layer become the input of SOM Layer 2 and re-learning occurs. With this multi-layered SOM learning, we can avoid mapping errors among similar nodes of different color information. In search, we put the query image vector into SOM layer 2 and select nodes of SOM layer 1 that connects with chosen BMU of SOM layer 2. In experiment, we verified that the proposed SIM was better than the original SIM and avoid mapping error effectively.

  • PDF

A Study on the Evaluation of Ready-Made Jacket for Women according to Pattern Size Using 3D Scanner (3D scanner를 이용한 여성복 재킷의 패턴 사이즈에 따른 착의평가 연구)

  • 서추연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.3_4
    • /
    • pp.390-401
    • /
    • 2002
  • This study was to evaluate the fitness and the suitability of size specification of the ready made jacket for women by analysing pattern size and space between skin and clothing using 3D scanner. The results were as follows: 1. Pattern B had the lowest score and the feeling of wearing was significantly different among the given patterns even though all jacket size specification were the same. 2. Ease amount was different between each brand even though the jacket size specification was the same due to the different pattern grading rules. And increasing grading amounts were bigger in horizontal direction rather than in vertical direction. 3. We could obtain accurate a 3 dimensional figure, using 3D scanner which was very useful and more accurate than 2 dimensional data using photography method. 4. Analyzing the average space between skin and clothing of each pattern, there was no significant difference in the average space between skin and clothing among all patterns except waist part of B88 size. And analyzing the average space between skin and clothing of each measured body parts by each size, there existed a significant difference in the interscye, abdomen and hip parts.

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.

A study on the distribution of glitter particles from an university building (대학 강의실에서 글리터의 분포 연구)

  • Hong, Sungwook;Cho, Hyoung-Woo;Son, Da-som;Lee, Seul-Bi
    • Analytical Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.288-298
    • /
    • 2015
  • A distribution study of glitter was conducted from a local university building. The potential recipient surfaces chosen were the 1,000 chairs kept in 16 separate classrooms of the building. The surface of chairs contacting with buttocks and back of users were tape lifted with commercial adhesive tapes, and the surface of adhesive tapes were examined with a stereomicroscope to locate the glitters. 12 glitter particles were found from 11 chairs kept in 16 classrooms of a building. This result indicates that the possibility of glitter finding from Korean violent crime scene is high. The 12 glitters found from the chairs were analyzed with a stereomicroscope and an FTIR spectrophotometer to find the matching glitter. The stereomicroscope was used for the observation of the shapes, dimensions, colors and holograms of each glitter, and the FTIR spectrophotometer was used for the analysis of the chemical composition of the coating material of each glitter. The examination results revealed that 8 glitters out of 12 glitters were not sharing the common origin each other. Also, two glitters found from two separate classroom chairs share common microscopic and FTIR spectroscopic characteristics which indicating two glitters share common origin. The record of the students who had used the classrooms was traced and the authors could find that the classrooms where the same glitters were found were shared by a group of students who listen to the same class. This result implies that the path of the involved people should be considered while assessing the value of trace evidence.

Correlation between Self-evaluation Factor and Academic Achievement of Medical Students according to Introduction of Explanation Meeting in Cadaveric Dissection (해부설명회의 도입에 따른 의학전문대학원생들의 자기 평가 요인과 학업성취도 상관관계 분석)

  • Park, Jeong-Hyun;Kim, Jee-Hee;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2475-2482
    • /
    • 2010
  • This study aimed to evaluate correlation between self-evaluation factors(satisfaction, linkage with major, suitability of management, verbal and non-verbal communication) and academic achievement of medical students according to introduction of explanation meeting in cadaveric dissection. The study was carried out that medical students(n=57) explained cadaveric structure to health allied sciences students and discussed with each other. Just after the meeting,, medical students filled out a questionnaire on impact of self-evaluation factors and communication. We analyzed these factors and their scores using frequency analysis, T-test and analysis of variance. Regardless of their gender, age, previous experience, the majority of the students gave high scores in all of self-evaluation factors. Among them, only verbal communication factor was closely related to their academic achievement(p<0.05). The verbal and non-verbal communication also had a high correlation of 0.673(p<0.01). The explanation meeting provided chance to learn further with positive attitude to medical students and motivated them academically. Additionally, they realized that communication skill played a key role in transmitting medical knowledge to others. Therefore, introduction of communication-based explanation meeting would be very useful tool in improving educational efficiency.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF