• Title/Summary/Keyword: 사위검사

Search Result 73, Processing Time 0.021 seconds

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Measurement of Heterophoria by Alternative Cover Method Using a Color Filters (색필터와 교대가림법을 이용한 새로운 사위측정)

  • Park, Sun-Young;Yu, Dong-Sik;Lee, Sun-Haeng;Kim, Sang-Yeob;Cho, Hyun-Gug
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.894-897
    • /
    • 2010
  • 적청 색필터와 새로운 시표를 이용한 교대가림법(Twinkle R/B법)이 임상적으로 새로운 사위검사법으로 사용될 수 있는지 그 가능성을 평가하였다. 대학생 109명(남 73명, 여 36명)을 대상으로 Twinkle R/B법, Modified Thorington법, Howell법, 그리고 Von Graefe법으로 40cm 거리에서 사위검사를 실시하였다. 사위검사는 검사자별로 반복 측정을 실시하여 검사방법에 따른 신뢰도를 평가하였다. 실험 결과, 검사자의 반복측정에 따른 신뢰도는 Twinkle R/B법이 가장 높았다. 결과적으로 Twinkle R/B법은 신뢰도가 높은 사위검사법으로서 임상에서 충분히 사용 가능한 것으로 나타났다.

  • PDF

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

Analysis of Induced Heterophoria Variations by Repeated Binocular Vision Examinations (반복된 양안시 검사로 유발된 사위도 변화 분석)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Song, Yun-Young;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.281-286
    • /
    • 2018
  • The purpose of this study was to evaluate the degree of heterophoria variations according to visual fatigue induced by increasing number of examinations while repeating binocular vision examinations. Twenty - one adults in their twenties who had no heterotropia other eye disease or systemic disease underwent binocular vision examinations. As the examinations progressed, the degree of heterophoria increased in both orthophoria and heterophoria. When the distance examinations was repeated 5 times, orthophoria increased degree of $1.56{\Delta}$ heterophoria. and heterophoria increased degree of $1.63{\Delta}$ heterophoria. When the near examinations was repeated 5 times, orthophoria increased degree of $1.78{\Delta}$ heterophoria. and heterophoria increased degree of $2{\Delta}$ heterophoria.. As the number of examinations increased, the result gradually deviated from the normal range as visual fatigue increased. The degree of the variation is judged to be enough to make the wrong prescription in the clinic. In conclusion, it was found that the binocular vision examinations should be conducted more accurately and promptly.

Comparisons of Phoria Test Among Prism Settings of Von Graefe Technique (Von Graefe법의 프리즘 세팅에 따른 사위검사의 비교)

  • Yu, Dong-Sik;Ha, Eun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.211-218
    • /
    • 2015
  • Purpose: The aim of this study was to compare the differences among prism settings of the von Graefe technique for phoria measurement. Methods: Thirty eight healthy subjects (mean age $22.35{\pm}2.72years$) were tested with eye examination by interview, cover test, and refraction. Phorias were measured in a random order using four prism settings for the von Graefe method: base-in (BI) and base-up (BU), BI and base-down (BD), BU and BI, and BD and BI over the right and left eye, respectively. Results: Among the four prism settings in measurements of lateral and vertical phoria, there were not significant differences at distance, whereas there were significant at near. The reliability of near lateral phoria (ICC: 0.95) was good, but that of near vertical phoria was less reliable (ICC: 0.83). In comparisons of the paired t-test, the 95% limits of agreement, and mean difference between prism settings, BU had more useful than other prism settings at near phoria. Conclusions: Results from this study suggest that the von Graefe test with BU or BU including other setting prisms have useful methods, especially for near phoria measurements.

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF