• Title/Summary/Keyword: 비파괴탐사

Search Result 125, Processing Time 0.023 seconds

GEOTECHNICAL ENVIRONMENT SURVEY (2) (고심도 지반환경 조사 - 비파괴 물리탐사의 적용 (2))

  • HoWoongShon;SeungHeeLee;HyungSooKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.4
    • /
    • pp.261-268
    • /
    • 2003
  • Lots of various utilities are buried under the surface. The effective management of underground utilities is becoming the very important subject for the harmonious administration of the city. Ground Penetrating Radar(GPR) survey including other various underground survey methods, is mainly used to detect the position and depth of buried underground utilities. However, GPR is not applicable, under the circumstances of shallow depth and places, where subsurface materials are inhomogeneous and are composed of clay, salt and gravels. The aim of this study is to overcome these limitations of GPR and other underground surveys. High-frequency electromagnetic (HFEM) method is developed for the non-destructive precise deep surveying of underground utilities. The method is applied in the site where current underground surveys are useless to detect the underground big pipes, because of poor geotechnical environment. As a result, HFEM survey was very successful in detecting the buried shallow and deep underground pipes and in obtaining the geotechnical information, although other underground surveys including GPR were not applicable. Therefore this method is a promising new technique in the lots of fields, such as underground surveying and archaeology.

  • PDF

A study about frequency domain analysis of impact-wave for detecting of structural defects in the concrete structure (구조물의 안전진단을 위한 충격파의 주파수 영역 탐사에 관한 연구)

  • Suh Baeksoo;;Kim Hyoungjun;Lee Sangchul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.165-180
    • /
    • 2005
  • Impact seismic wave test is a method for nondestructive testing of concrete structure using of stress wave which is propagated and reflected from internal flaws within concrete structure and external surface, In this study, we performed non-destructive testing using impact seismic wave test for safety diagnosis of civil engineering structures. For this, I've compared and analized the result in the way of reflective method mostly using on one-dimension such as tunnel lining, and penetration method using the way of cross hole and tomography.

  • PDF

제주도 지하수 문제에서 물리탐사의 역할

  • 이상규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1994.07a
    • /
    • pp.75-91
    • /
    • 1994
  • 제주도의 지하수는 상위지하수, 기저지하수, 연안용출수, 심부지하수 등으로 분류될 수 있다. 이들을 효율적으로 활용하고 또 보존, 관리하기 위하여는 탐사가 선행되어야 한다. 구성물질의 물성대비를 탐사의 원리로 하는 물리탐사는 간접적 정보를 제공한다는 점에서 조사단계에서 흔히 간과되어 왔으나, 지표 상부에서 지하 심부까지의 정보를 제공할 수 있는 유일한 탐사방법이라는 점에서 그 중요성이 재인식되어야 한다. 물리탐사는 비파괴적인 탐사방법일 뿐 아니라 날은 탐사범위를 상대적으로 짧은 기간에 탐사할 수 있는 경제성을 갖고 있기 때문에 결과적으로 조사단계에서 소요되는 총비용을 현저히 줄일 수 있기 때문이다. 필자는 여기서, 제주도의 지하수문제에 대하여 물리탐사가 담당할 수 있는 역할에 대하여 최근의 탐사실례들을 통하여 기술하고자 한다. 이들 중에는 '복합 물리탐사방법에 의한 지하수탐사', '항공원격탐사에 의한 해안 용출수탐사', '물리탐사에 의한 해수침입영역 조사' 그리고 지하수 부존과 밀접한 관련이 있는 '지질구조선 탐사' 등이 포함되어 있다. 후속의 지질조사와 시추조사에서 얻은 직접적 정보들이 물리탐사에 의한 해석에 feedback 될 수 있는 조사체계를 갖춘다면 향후 제주도의 지하수와 관련한 문제에 물리탐사가 보다 효과적으로 사용될 수 있을 것임을 강조한다.

  • PDF

Ground Stability Interpretation of the Five-storied Stone Pagoda at the Muryangsa Temple, Korea; An Examined by the Nondestructive Survey (비파괴 탐사를 이용한 무량사오층석탑 지반안정해석)

  • Chae, Sang-Jeong;Suh, Man-Cheol
    • Journal of Conservation Science
    • /
    • v.20
    • /
    • pp.43-54
    • /
    • 2007
  • The Muryangsa temple five-storied stone pagoda (Treasure No. 185) was geographically located in the area of the Baekje Kingdom. The architectural style of the Muryangsa temple five-storied stone pagoda is the pagoda at the early Goryeo Dynasty that was succeeded technique of the Baekje Kingdom and form of the Shilla Kingdom. Because this pagoda is located outside during old time that it received serious petrological and biological weathering in rock blocks and occurred the center subsidence in the upper capstone. This study executed ground stability interpretation in order to know what central subsidence in the upper capstone occurred for soft ground. The ground stability interpretation used seismic survey, electrical resistivity survey and GPR survey by non-destructive method. As the result, the ground appeared in the condition which is good. Specially, high resistance zone appeared from electric resistivity survey which come to seem with ground reinforcement harden. Consequently, central subsidence condition in the upper capstone is not by the instability of ground, and is judged with the thing by the structure instability in rock blocks over the upper capstone. This will be applied basic data with the long-term monitoring or preservation countermeasure of the pagoda.

  • PDF

Experiments on the Detection of Delamination in FRP Reinforced Concrete (탄소섬유 보강 콘크리트의 박리 탐사 실험)

  • Rhim, Hong-Chul;Jung, Hang-Chul;Woo, Sang-Kyun;Song, Young-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.3-9
    • /
    • 2007
  • With a growing concern about the state of infrastructure worldwide, the demand for the development of reliable nondestructive testing techniques (NDT) is ever increasing. Among possible NDT techniques, microwave method is proven to be effective in fast and non-contact inspection of concrete structures and inclusions inside concrete. It is also found that the microwave method has a potential in detecting the delamination between fiber reinforced polymers (FRP) plate and concrete. On the other hand, ultrasonic method can be another way to find the delamination. In this paper, the research work needed for the development of a reliable microwave method and ultrasonic method is studied in the measurements of concrete specimens reinforced with FRP. Concrete specimens are made with FRP and artificial delamination inside. A microwave measurement system with hom antennas with high center frequency and broad frequency bandwidth are used to image inside concrete specimens for the detection of debonding between concrete and FRP. Also, ultrasonic method is used for the same condition. Both results are compared with each other.

Introduction to nondestructive testing

  • 정용무
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.1-10
    • /
    • 1994
  • 이 글에서는 비파괴검사개론에 관하여 알아보았다. 1. 비파괴검사의 의의 1.1 비파괴검사의 역사 1.2 비파괴검사의 원리 1.3 비파괴검사의 목적과 역할 1.3.1 품질관리 1.3.2 생산원가의 절감 1.3.3 품질의 평가 1.3.4 점검 1.4 비파괴검사자의 역할 2. 비파괴검사자의 방법 2.1 방사선투과시험 2.1.1 직접촬영법 2.1.2 투시법 2.1.3 전자사진법 2.1.4 계기법 2.2 초음파탐상시험 2.2.1 음향검사와 초음파탐상 2.2.2 초음파의 성질과 종류 2.2.3 접촉매질 2.2.4 초음파 탐상 방법 2.2.5 초음파 탐촉자 2.3 자기탐상시험 2.3.1 자기탐상 원리 2.3.2 자기탐상 방법 1) 자장측정 탐상법 2) 자기기록 탐상법 3) 탐사 코일법 4) 자분탐상시험 2.3.3 자분탐상시험 2.4 침투탐상시험 2.4.1 침투탐상시험의 원리 2.4.2 침투탐상시험법의 기본 1) 침투탐상시험의 종류 2) 현상체의 종류 2.4.3 침투탐상시험의 장단점 2.5 전자유도시험 (와전류탐상법) 2.5.1 와전류의 발생과 탐지 2.5.2 와전류의 탐지 2.5.3 와전류 탐촉자 2.5.4 와전류 탐상시험의 적용과 장단점.

  • PDF

Crack Detection of Concrete Using Fiber Optic Cables (Fiber Optic Cable을 이용한 콘크리트 균열탐사)

  • Cho, Nam-So;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Crack detection technique for concrete structures has been developed in this study. Experimental tests were carried out to detect a surface and internal crack, employing common fiber optic cables and OTDR(optical time domain reflectometry), an optical signal analyzer which is widely used to detect damages at fiber optic cables in the field of optical engineering. While initial concrete crack is ready to occur under cracking force, the occurrence and location of the crack are simultaneously detected to give the same damage to fiber optic cables which have been attached to and/or embedded into concrete in advance. It is obtained through successive tests that the principal factors for crack detection is the covering state of fiber optic cable, and total 4 tests including a preliminary test were conducted and the crack detection technique was verified. The practical usefulness would be expected at crack management and maintenance of concrete structures.