• Title/Summary/Keyword: 비틀림교합

Search Result 4, Processing Time 0.029 seconds

Effects of Occlusal Condition and Clenching Force on the Mandibular Torque Rotational Movement (교합조건 및 이악물기 힘의 변화가 하악의 비틀림 회전운동에 미치는 영향)

  • Oh, Min-Jung;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.411-426
    • /
    • 2005
  • The purpose of this study was to investigate the effects of occlusal condition and clenching level on the mandibular torque rotational movement. For this study, healthy 14 men without any symptoms and signs of temporomandibular disorders were selected. Mandibular torque rotational movement was observed in each circumstance of combination of three occlusal conditions such as natural dentition, with wafer of 3.6 mm thickness, and wafer with resin stop of 14 mm thickness total during hard biting of bite stick at maximum voluntary contraction(MVC) and 50% of MVC level of surface EMG activity of masseter muscle. Electromyographic activity and mandibular torque rotational movement were observed using BioEMG and BioEGN in $BioPak^{(R)}$ system. Each biting movement in each circumstance was composed of clenching one time and hard biting of wooden stick two times. The observed items were opening distance, velocity and amount of torque rotational movement in mandibular movement, and the data were statistically processed with $SPSS^{(R)}$ windows (ver.10.0). The results of this study were as follows: 1. There were no differences in the mandibular movement distance between those value in both biting sides, and between those in both clenching forces, but the mandibular velocity showed a different results by clenching force. For the amount of torque rotational movement, there were no difference in the value of the frontal plane but some significant difference was in the value of the horizontal plane by biting side. 2. The mandibular movement distance and the mandibular velocity in both planes were higher by maximum voluntary contraction than those by half maximum voluntary contraction, and amount of torque rotational movement in the horizontal plane was also increased by maximum voluntary contraction. 3. The opening distance in both planes were decreased with the increase of vertical dimension of occlusion, namely, by the occlusal appliances, and this pattern was also showed in the mandibular velocity in case of hard biting by maximum voluntary contraction. However, the amount of torque rotational movement were not different by the increase of vertical dimension of occlusion. 4. The value of angle and distance of the torque rotational movement in the hard biting of wooden stick were generally higher than those in the clenching without wooden stick in both planes without regard to occlusal conditions and/or clenching forces.

Correction of Tooth-to-tooth Contact and Class IV Mesiodistocclusion by Orthodontic Tooth Movement in Three Dogs (세 마리 개에서 교정적 치아이동에 의한 치아-치아 접촉 및 IV급 근원심교합의 교정)

  • Kim, Se-Eun;Shim, Kyung-Mi;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Three Maltese dogs, 5 to 7 months old, were admitted to the Veterinary Medical Teaching Hospital, Chonnam National University with malocclusion including Class IV mesiodistocclusion. In the first case, the treatment was performed by moving the mandibular canine teeth caudally with orthodontic buttons and Masel chains. The second patient was treated for rostroverted mandibular canines using buttons and chains. When distal movement of the mandibular canine teeth was completed, a maxillary arch wire with finger springs was applied to push the incisor teeth forward. In the third case, the treatment began by moving the mandibular canine teeth caudally with buttons and chains. An arch wire with finger springs was applied at maxilla to move the maxillary incisor teeth labially. Additionally, the mandibular incisor teeth were moved lingually by an elastic band attached to the buttons cemented to mandibular canine teeth. As a result, all patients successfully regained a normal occlusion.

An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures (표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구)

  • Ye, Sun-Hae;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.203-211
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the reosseointegration periods when the rough surface implants, which had complete bone-implant ankylosis, suddenly losed the osseointegration. Materials and Methods: The implants with RBM surface treatment were inserted into both tibias of 23 rabbits. Two implants were submerged into each side. After six weeks, the primary removal torque was measured by Digital torque gauge, and then the implants were replaced and submerged to estimate the level of reosseointegration. After assigned healing periods for each group, the removal torque was measured again. BIC (Bone-Implant contact, %) ratio was measured through histomorphometric analysis.Paired t-test was processed by SPSS 14.0. One-way ANOVA and Tukey's post-hoc test was processed to analyze statistically significant differences among the groups. Results: In comparison with the primary removal torque, the secondary removal torque was increased after 11 days and significantly increased from 2 weeks. In fluorochrome labeling, the origin of mineralization was observed after 7 days, which showed as fluorescent bands around the bone-implant interfaces. After 11 days, the bone formation was apparent, and it is increased continuously with the passage of the time. Conclusion: In 11 days after the implant replacement, the secondary removal torque was almost as same as the primary value, and was significantly higher from 2 weeks. The mineralized shapes were observed in 7 days after the implant replacement, and then the bone formation appeared visibly in 11 days.

Effects of Occlusal Appliance on the Mandibular Position and the Mandibular Rotational Torque Movement during Speech (교합장치가 발음시 하악위 및 하악의 비틀림 회전운동에 미치는 영향)

  • Kim, Moon-Gyu;Han, Kyung-Soo;Kim, Jong-Young;Yang, Keun-Young
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.1
    • /
    • pp.59-73
    • /
    • 2001
  • This study was performed to investigate the effects of occlusal appliance on the mandibular position and the mandibular rotational torque movement during speech. For this study, 20 patients with temporomandibular disorders(TMDs) and 20 normal subjects without any signs and symptoms in the masticatory system were selected as the patient group and as the normal group, respectively. Biopak $system^{(R)}$(Bioresearch Inc., Milwaukee, USA) and a sentence of 'Sue is missing her house' were used for recording and for observing of speech pattern. There were five mandibular positions observed in this study, that is, mandibular rest position, 'ssi', 'her', 'ha', and 's' speech position. In each position, slant and A-P distance in sagittal plane, vertical distance and lateral distance in frontal plane were measured. Amount of the mandibular rotational torque movement were measured at 'her', 'ha' speech position and for all through speech movement. Centric relation splint(CRS) was placed in both groups, but anterior or posterior bite plane were placed in normal subjects only. Data collected were processed and analysed by SPSS windows program. The results of this study were as follows : 1. Mandibular positions in both groups were not different before adaptation, with CRS, and after removal, but total amount of the mandibular rotational torque movement was greater in patients. 2. Mandible was slightly placed anteriorly with CRS at 'her' and 'ha' speech position in patients, but was placed anteriorly at all the five positions in normal subjects. 3. Difference with type of occlusal appliance in normal subjects were noted only for vertical distance at 'ssi' and 'ha' speech position, and the distance with CRS were more than that with posterior bite plane. 4. Mandibular rotational torque movement at 'her' and 'ha' speech position was greater in patients, but the difference was disappeared after appliance removal. And the torque movement was greater at 'ha' speech position than that at 'her' speech position in frontal plane. It could be concluded that the adaptation of occlusal appliance showed a tendency to locate the mandible anteriorly during speech in both groups, but did not affect total mandibular rotational torque movement which was greater in patients.

  • PDF