• Title/Summary/Keyword: 비침습적 검사

Search Result 226, Processing Time 0.025 seconds

The Usefulness of Capsule Endoscopy in Diagnosis of Small Bowel Diseases (소장질환의 진단에 캡슐내시경 검사의 유용성)

  • Eun, Jong-Ryul;Jang, Byung-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2006
  • Background: This study was conducted to evaluate the usefulness of capsule endoscopy (CE) for the diagnosis of small bowel diseases. Materials and Methods: We reviewed the medical records of 66 patients (mean age: 52.1 years, male/female: 39/27), who underwent CE at Yeungnam University Hospital from August 2003 to March 2006. Results: Suspicious gastrointestinal (GI) bleeding presenting as anemia or history of gross bleeding was the most common reason to perform CE (71.2%). Other indications included GI symptoms (21.2%) such as abdominal pain/discomfort, nausea, diarrhea, and others (7.6%). In studies performed for GI bleeding (n=47), ulcer/erosion was the most common finding (n=22, 46.8%) followed by tumor (n=5, 10.6%), angiodysplasia (n=3, 6.4%), polyp (n=3, 6.4%), active bleeding (n=1, 2.1 %), ulcer with stenosis (n=1, 2.1%), and normal findings (n=12, 25.5%). Of these, a bleeding focus was detected in 32 cases (68.1%) undergoing CE studies. Among 14 patients with GI symptoms, only two patients had typical findings related with symptoms. Surgical resection was performed in five cases with tumor. Of these, four were diagnosed as gastrointestinal stromal tumor and the other one was a lymphangioma. There were no complications associated with the CE procedure. Conclusion: Capsule endoscopy is a safe, noninvasive diagnostic tool for small bowel diseases and may be useful for the diagnosis of small bowel hemorrhage including obscure bleeding. However, further studies are needed to confirm its utility for abdominal symptoms other than hemorrhage because of the low diagnostic yield.

  • PDF

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.

Real-time Reverse Transcription Polymerase Chain Reaction Using Total RNA Extracted from Nasopharyngeal Aspirates for Detection of Pneumococcal Carriage in Children (소아에서 폐렴구균 집락률 측정을 위해 비인두 흡인 물의 총 RNA를 이용한 실시간 중합효소 연쇄반응법)

  • Kim, Young Kwang;Lee, Kyoung Hoon;Yun, Ki Wook;Lee, Mi Kyung;Lim, In Seok
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: Monitoring pneumococcal carriage rates is important. We developed and evaluated the accuracy of a real-time reverse transcription polymerase chain reaction (RT-PCR) protocol for the detection of Streptococcus pneumoniae. Methods: In October 2014, 157 nasopharyngeal aspirates were collected from patients aged <18 years admitted to Chung-Ang University Hospital. We developed and evaluated a real-time PCR method for detecting S. pneumoniae by comparing culture findings with the results of the real-time PCR using genomic DNA (gDNA). Of 157 samples, 20 specimens were analyzed in order to compare the results of cultures, real-time PCR, and real-time RT-PCR. Results: The concordance rate between culture findings and the results of real-time PCR was 0.922 (P<0.01, Fisher exact test). The 133 culture-negative samples were confirmed to be negative for S. pneumoniae using real-time PCR. Of the remaining 24 culture-positive samples, 21 were identified as S. pneumonia -positive using real-time PCR. The results of real-time RT-PCR and real-time PCR from 20 specimens were consistent with culture findings for all S. pneumoniae -positive samples except one. Culture and real-time RT-PCR required 26.5 and 4.5 hours to perform, respectively. Conclusions: This study established a real-time RT-PCR method for the detection of pneumococcal carriage in the nasopharynx. Real-time RT-PCR is an accurate, convenient, and time-saving method; therefore, it may be useful for collecting epidemiologic data regarding pneumococcal carriage in children.

Intestinal Ultrasonographic and Endoscopic Findings in Pediatric Patients with Henoch-Sch$\"{o}$nlein Purpura and Gastrointestinal Symptoms (위장관 증상을 동반한 Henoch-Sch$\"{o}$nlein Purpura 환아의 장관 초음파 소견 및 내시경 소견)

  • Noh, Yun-Il;Ryu, Min-Hyuk;Jung, Chul-Zoo;Lee, Dong-Jin;Kwon, Jung-Hyeok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.181-190
    • /
    • 2001
  • Purpose: The aim of this study is to investigate the usefulness of intestinal ultrasonography (US) and upper gastrointestinal endoscopy in the early diagnosis of Henoch-Sch$\"{o}$nlein purpura (HSP) with the gastrointestinal (GI) symptoms preceding the emergence of the skin lesion. Methods: The clinical, intestinal US and upper gastrointestinal endoscopic records of 85 patients (88 cases) with GI symptoms relating to HSP presenting between January 1999 and April 2001 were reviewed. Results: 1) GI symptoms were observed in 52 cases (59%) and skin, joint, renal and scrotal manifestations were observed in 88 (100%), 64 (73%), 15 (17%), 3 cases (3%) respectively. 2) Out of 52 cases with GI symptoms, abdominal pain was observed in all cases (100%). Positive stool occult blood, nausea and vomiting, abdominal tenderness, melena or tarry stool, diarrhea, hematemesis, rebound tenderness and rigidity were observed in 28 (50%), 17 (33%), 17 (33%), 12 (23%), 6 (12%), 4 (8%), 1 (2%) and 1 case (2%) respectively in order of frequency. 3) Intestinal US examination was performed in 27 cases with HSP and GI symptoms (52 cases). Out of 27 sonographic examinations 22 showed abnormal findings. Thickening of the duodeno-jejunal wall was observed in 16 cases (73%). Free peritoneal fluid, enlarged mesenteric lymph node, ileus and abnormal gall bladder were seen in 8 (36%), 8 (36%), 4 (18%) and 1 case (5%) respectively. In three cases of HSP without GI symptoms, those changes were absent. 4) In all of five cases with HSP and GI symptoms, endoscopic study showed mucosal edema and multiple hemorrhagic erosions especially at the second portion of the duodenum. Biopsy specimens from the duodenum of 2 cases out of 5 endoscopic examinations showed acute inflammatory infiltrates in the mucosa with hemorrhage. 5) Both intestinal US and endoscopic studies were performed in 4 cases with HSP and GI symptoms simultaneously. Out of 4 those cases, 3 cases showed the thickened duodeno-jejunal wall on the intestinal US, which suggested erosive hemorrhagic duodenitis by endoscopic findings. Conclusion: The typical but nonpathognomonic intestinal US findings including the thickening of the duodeno-jejunal wall and upper gastrointestinal endoscopic findings including hemorrhagicerosive duodenitis, in children with GI symptoms, should be considered a manifestation of HSP, even in the absence of skin lesion.

  • PDF

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

Histological Evaluation of Bioresorbable Threads in Rats (랫드에서의 생분해성 매선요법에 대한 조직학적 분석)

  • Lee, Chang Gun;Jung, Jaeyun;Hwang, Samnoh;Park, Chan Oh;Hwang, Soonjae;Jo, Minjeong;Sin, Min Hi;Kim, Hyun Ho;Rhee, Ki-Jong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.217-224
    • /
    • 2018
  • Thread lifting has become popular as a minimally invasive technique for facial rejuvenation. Commercially available threads are composed of poly-L-lactic acid (PLLA), polycaprolactone (PCL), or polydioxanone (PDO). However, the histological changes that occur in response to implanted threads are unclear. The aim of this study was to evaluate histological changes that occur in response to implantation with three types of bioresorbable threads (PLLA, PCL, PDO) in rat skin. PLLA, PCL and PDO threads were implanted in the dorsal skin of Sprague Dawley rats and tissue samples were harvested 2, 4, 8 and 12 weeks post-implantation. To evaluate histologic changes induced by bioresorbable face-lifting threads, tissue samples were stained with hematoxylin & eosin, Masson's trichrome stain and Herovici's collagen stain. All three threads induced neocollagenesis of type 3 collagen in the rat skin. The amount of collagen induced by the threads was dependent on the thread surface area. The PDO cavern-type thread was most effective in inducing neocollagenesis due to its extensive surface area. Our results suggest that type 3 collagen induced by bioresorbable threads depends on the thread surface area to uphold the dermis and contributes to facial rejuvenation.

Percutaneous Radiofrequency Therapy of Benign Bone Tumors in the Femoral Head (대퇴골두 부위에 발생한 양성 골 종양에 대한 경피적 고주파치료 (증례보고))

  • Seo, Jai-Gon;Kim, Eung-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.84-92
    • /
    • 2003
  • Purpose: To report two cases of bone tumors other than osteoid osteoma in the proximal femur and treated with percutaneous high frequency radioablation method. Cases: We reviewed two cases with intracortical chondroma and enchondroma in the femoral head retrospectively. The patient with intracortical chondroma was a thirty one year old woman and had suffered right hip pain of 1 year duration. The lesion was located in the head of right femur and treated with CT guided percutaneous high frequency radioablation after needle biopsy under general anesthesia. The symptom was gone immediately after the procedure and was discharged postop. 1 day. 15 months has passed without symptom recurrence. Second case having enchondroma, was 56 year old woman complaining of gluteal area pain for 3 months. Radiologic evaluation showed osteolytic lesion with sclerotic rim on the inferior portion of the left femoral head. She received a same therapy with CT guided radiofrequency ablation following needle biopsy. She reported dramatic pain relief after the procedure and was discharged postop. 1 day. No symptom has occurred for 3 months until now. Conclusion: We present 2 cases of bone tumor occurred in the hip joint area other than osteoid osteoma which were treated with CT guided radiofrequency ablation.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Antibiotics Susceptability of Streptococcus pneumoniae Isolated from Single Tertiary Childrens' Hospital Since 2014 and Choice of Appropriate Empirical Antibiotics (최근 4년간 국내 단일 의료기관을 내원한 소아청소년에서 분리된 폐구균의 항생제 감수성 양상 분석)

  • Jung, Jiwon;Yoo, Ree Nar;Sung, Hungseop;Kim, Mina;Lee, Jina
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: We investigated the distribution and antimicrobial resistance of pneumococcal isolates from hospitalized children at Asan Medical Center for recent 4 years, and aimed to recommend proper choice of empirical antibiotics for pneumococcal infection. Methods: From March 2014 to May 2018, children admitted to Asan Medical Center Childrens' Hospital with pneumococcal infection were subjected for evaluation of minimal inhibitory concentration (MIC) for ${\beta}-lactams$ and macrolide antibiotics. Patient's age, underlying disease, gender were retrospectively collected. Using Monte Carlo simulation model and MIC from our study, we predicted the rate of treatment success with amoxicillin treatment. Results: Sixty-three isolates were analyzed including 20.6% (n=13) of invasive isolates, and 79.4% (n=50) of non-invasive isolates; median age were 3.3 years old, and 87.3% of the pneumococcal infections occurred to children with underlying disease. Overall susceptibility rate was 49.2%, 68.2%, and 74.6% for amoxicillin, parenteral penicillin, and cefotaxime respectively. 23.8% and 9.5% of the isolates showed high resistance for amoxicillin, and cefotaxime. Only 4.8% (n=3) were susceptible to erythromycin. Monte Carlo simulation model revealed the likelihood of treatment success was 46.0% at the dosage of 90 mg/kg/day of amoxicillin. Conclusions: Recent pneumococcal isolates from pediatric patients with underlying disease revealed high resistance for amoxicillin and cefotaxime, and high resistance for erythromycin. Prudent choice of antibiotics based on the local data of resistance cannot be emphasized enough, especially in high risk patients with underlying disease, and timely vaccination should be implemented for prevention of the spread of resistant strains.

Assessment of Right Ventricular Function in Patients with Chronic Obstructive Pulmonary Disease Using Echocardiographic Tei Index (만성 폐쇄성 폐질환 환자에서 Tei 지수를 이용한 우심실기능 평가)

  • Oh, Yoon-Jung;Shin, Joon-Han;Kim, Deog-Ki;Choi, Young-Hwa;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.343-352
    • /
    • 2001
  • Background : Advanced chronic obstructive pulmonary disease is characterized by progressive pulmonary hypertension leading to right heart dysfunction, which plays a Important role in clinical evaluation but remains difficult and challenging to quantify. The noninvasive doppler echocardiographic value referred to as the Tei index has been suggested as a simple, reproducible and reliable parameter of the right ventricular function. The purpose of this was to assess the right ventricular function in patients with chronic obstructive pulmonary disease using the Tei index and to evaluate its relationship with the pulmonary functional status. Methods : The study population comprised of 26 patients with chronic obstructive pulmonary disease and 10 normal control subjects. The Tei index was obtained by dividing the sum of the isovolumetric contraction and the relaxation times by the ejection time using a pulsed-wave doppler. It was compared with the other available Doppler echocardiographic parameters of systolic or diastolic function and with the pulmonary function of the patients. Results : The Tei indices of the patients with COPD were significantly higher than those of normal subjects($0.45{\pm}0.17$ vs. $0.27{\pm}0.03$, p<0.01). The isovolumetric contraction time/ejection time($0.32{\pm}0.08$ vs. $0.25{\pm}0.05$, p<0.05), the isovolumetric relaxation time/ejection time($0.29{\pm}0.16$ vs. $0.15{\pm}0.08$, p<0.05)and the preejection period/ejection time ($0.46{\pm}0.10$ vs. $0.38{\pm}0.06$, p<0.05) were prolonged and the ejection time ($255.2{\pm}32.6$ vs. $314.2{\pm}16.5$ msec, p<0.05) was significantly shortened in patients with COPD compared to normal subjects. The tei indices were inversely correlated with the $FEV_1$ (r=-0.46, p<0.05) and were prolonged significantly in patients with a severe obstructive ventilatory dysfunction(less than 35% of predicted $FEV_1$) compared to those with a mild and moderate ventilatory dysfunction. The tei indices showed an inverse correlation to with the ejection time (r=-0.469), the isovolumetric contraction time/ejection time(r=0.453), the isovolumetric relaxation time/ejection time(r=0.896) and the preejection period/ejection time(r=0.480). Conclusion : The tei index appeared to be a useful noninvasive means of evaluating the right ventricular function. It revealed a significant correlation with the pulmonary function in patients with COPD.

  • PDF